Aquaphor dwm 101 morion DIY repair

In detail: aquaphor dwm 101 morion DIY repair from a real master for the site my.housecope.com.

bought this mouse, and he is without a wire. still some kind of heavy, as if with ...

Hello! I have a gigabyte gsmart i350. such a problem: I can not connect ...

suspended, embedding width: 60 cm, operating modes: drain / circulation, ...

Image - Aquaphor dwm 101 morion DIY repair

core: 650 MHz, RAMDAC: 400 MHz, memory: 512 MB, GDDR3, 1800 MHz, 256 bit, DVI x2

number of channels: 2.1, power 40 W, 30-20000 Hz, speaker material: MDF, material ...

And we will send all user responses to your question directly to your email address. Not a single question will remain unnoticed by site visitors.

The problem is this: at first, apparently, the valve went out of order - after the tank was set, water continued to flow into the filtration unit and was discharged into the sewer (I watched for several hours); after emptying the tank, the water, emitting hissing and hissing sounds, continued to flow into the installation (checked by the water meter) and, bypassing the tank, was drained into the sewer. At the moment, the water supply valve to the installation is closed. What to do next?

The most common breakdowns of Aquaphor Morion hydroautomatics units and how to repair them.
Detailed consultations by phone.
Selection of equipment sale and installation of water treatment systems from domestic to industrial
Danil Dmitrievich
Tel. 8775 808 0002

Image - Aquaphor dwm 101 morion DIY repair

Repair of a bathroom in an apartment on your own and with your own hands. It's not difficult, you just need a desire, free time and watching this educational video :). Bathrooms, toilet, decoration, renovation and bathroom interior design. The video also touches on the repair and design of a toilet in a standard city apartment. They also touch upon such a complex topic as the repair and replacement of plumbing equipment, repair of water pipes, replacement of taps and toilet bowls. Is it difficult to repair the sewerage system? Nothing complicated! Afraid of ruining your bathroom and toilet with your renovations? Do not be afraid! You will succeed! Bathroom renovation is easy! A channel with videos on construction topics: bathroom repair, bathroom repair, bathroom design, toilet repair, plumbing repair, how to do it yourself, with your own hands, how you can, how correctly, how beautifully, yourself, yourself, construction, repair ,

Video (click to play).

The buyers who contact our company mostly ask the same questions. How to choose a water filter from the many available? We will help you with this. We specialize in the selection, delivery and installation of water treatment equipment from domestic to industrial. Kazakhstan Karaganda Temirtau tel 87758080002 we are on Instagram _aquatem_

Description of the operation of the hydraulic valve circuit of the Aquaphor Morion filter. A more complete consultation can be obtained by phone Selection of equipment from household to industrial Consultation of a specialist Individual solution of water treatment problems at small and large facilities. Apartments, cottages, production, catering, restaurants and much more

Image - Aquaphor dwm 101 morion DIY repair

In appearance and description, it seems that these filters were designed by children in schools during labor lessons.

Image - Aquaphor dwm 101 morion DIY repair

Thank you for the video! The first 3 minutes of watching helped me 🙂
I went on vacation for 2 months - I am returning - Morion does not work.
Fills the tank with VERY little water.
Replaced all cartridges (5.t.r.) - to no avail, the problem was not resolved.
(by the way, the cartridges lasted a VERY long time: OSMO - 4.5 years; others - 3 years)
After watching the beginning of the video, I immediately checked the drain tube. It turned out to be clogged with dried sewer dirt at the junction of the "drainage" with the sewer pipe (under the sink).
Apparently, with regular use, the drainage tube was still self-cleaning, and during the vacation everything dried up to death. I cleared the blockage in the tube with a toothpick and MIRACLE! It all worked!
At first it was a pity for the 5 tr., Which I had already spent on cartridges (it was not the case with them), then I decided that I still needed to change them sometime :)
By the way, with such a long-term use of cartridges, scale did NOT appear in the kettle!
(That is, the filtration still worked. Maybe initially my water in the tap was very clean.)
Thanks for the video! It helped me!

Image - Aquaphor dwm 101 morion DIY repair

You can have a detailed video about replacing modules! Should the container be filled or emptied when replacing? How to flush cartridges if only K5 and K2 are changed?

Image - Aquaphor dwm 101 morion DIY repair

Thank you for the video. One question: there is one valve or two in the “block of check valves” between the membrane and the mineralizer, and if there are two, why? (Not counting the shut-off between K5 and K2 and a separate return to the clean water tap)

Video instruction for installing the Aquaphor DWM-101 Morion filter

Detail filter:

Aquaphor DWM 101 Morion is a unique filter with natural minerals for absolute purification, softening of water and reliable protection against bacteria.

Image - Aquaphor dwm 101 morion DIY repair

Why make a hole in the corrugation of the siphon?

Image - Aquaphor dwm 101 morion DIY repair

We advise you to watch the video - everything you need to know about this filter

Image - Aquaphor dwm 101 morion DIY repair

Image - Aquaphor dwm 101 morion DIY repair

make a video how to change the k50 membrane in this filter.

Image - Aquaphor dwm 101 morion DIY repair

please give a link how to look like a restrictor. is there a restrictor in model 101S? tell me whether it is normal that water is drained into the drain for a very long time (it pours for half an hour, if not more, while the pressure in the tap disappears and all the water goes into the drain). Should the membrane be inside with water, it feels like it does not allow water to pass through itself (it should only maintain the pressure balance)? Thank you

Image - Aquaphor dwm 101 morion DIY repair

How to disinfect the built-in water storage tank over time?

Image - Aquaphor dwm 101 morion DIY repair

Harmful bacteria are introduced, first in the tubes and then in the tank. They must either be changed over time or cleaned. The tubing is inexpensive and the tank is another matter.

Image - Aquaphor dwm 101 morion DIY repair

Image - Aquaphor dwm 101 morion DIY repair

What terrible dirty nails the plumber has, it's disgusting to look

Image - Aquaphor dwm 101 morion DIY repair

The instructions say to drill a hole for drainage with a 7mm drill, and the video says about 6mm. I drilled 6mm because Confused by the fact that the cross-section of the drain (black) tube is 6mm, the hole in the fitting-pad is also about 6mm. If you drill with a 7mm drill, the diameter of the hole in the fitting increases - I'm not sure if this will benefit the tightness of the connection.

Image - Aquaphor dwm 101 morion DIY repair

I will leave my negative comment. Aquaphor sells water purification filters and does not help consumers solve their problems. I came across an incomplete complete set, at the factories that they are manufactured do not undergo testing, this is 99.9% after I installed it according to the passport, water flowed on top of the collector, the chipboard furniture got wet and swollen. calls to ss are useless because they say that they themselves are to blame. although I do not consider myself far from plumbing work (I am a builder). here is such a bad service. maybe they have clean water, but the service is disgusting. In the waterfall store, the seller recommended me to buy a geyser, but I decided to take an aquaphor. in general, keep an eye on quality control. you have bad installation instructions. you have a bad package. you have a bad call center. working personnel are not particularly interested in technical support.

Image - Aquaphor dwm 101 morion DIY repair

It is interesting that in St. Petersburg there is a production of Aquaphor filters in Ust-Izhora, but in order to fix NI-NI there. WE ARE A STORE and we don’t sell any valves and we don’t have any service))

Image - Aquaphor dwm 101 morion DIY repair

Still pay some kind of master 1000 rubles for leaving and replacing parts ?? Of course, there is not a single service address on the site.

Image - Aquaphor dwm 101 morion DIY repair

+ AQUAPHOR - Water filters

The aquaphor service is ONLY a visit of the “master” to “diagnose” and replace parts. You can bring the filter yourself to the service, but you need to drag the filter with a FULL tank through the whole city with a decent weight and the difference with leaving is only 300-600 rubles. The master of course has to pay 2000 for a kind of repair.
Those. purchase and replacement of filters and membranes 3000 rubles + 2000 rubles. for the master = 5000 rubles. NEW Morion costs 7000 rubles.

And what can break from the tap pressure in the SIMPLEST filter? Why can't you make removable elements for replacement yourself?
You get money for the filters, you get for the device itself, but as soon as the warranty ends, the filter breaks and the user must pay 80% of the cost of the new device)) Business in Russian.

From the very beginning I heard negative reviews and now I regret not having bought a Barrier or something else.

Image - Aquaphor dwm 101 morion DIY repair

+ MrLekarstvo, hello!
We are sorry that you have a problem with the filter.
Many of our dealers have their own service department or contacts with a third party service.
Please look at the information about the representatives in your city (under the map with shops) on the page of your city in the section "Where to buy"

Image - Aquaphor dwm 101 morion DIY repair

The water stopped flowing. I bought a new set of cartridges. Water goes to drain. Product quality is below the baseboard. Execution for a deuce with a minus.

Image - Aquaphor dwm 101 morion DIY repair

+ MrLekarstvo, hello!
We sympathize with your situation,
Unfortunately, the performance of reverse osmosis filters depends on many factors, only a part of which is determined by the filter itself. In the case described by you, a constant flow of water into the drainage can occur because:
- the membrane is clogged - a normal situation (if it has served for 1-2 years or the water quality has deteriorated). If, after replacing the membrane and other modules, you did not rinse them according to the instructions, the problem could persist;
- the water supply pressure has dropped - the filter uses pressure to force water through the membrane. If the pressure drops, water will not be able to overcome the membrane and will be drained into the drain.
- something really happened to the filter and more serious diagnostics are needed.
Please consult our support center using the link or by calling the call center indicated on the website.
We hope for the soonest resolution of the difficulties with your filter.

Image - Aquaphor dwm 101 morion DIY repair

Junk your filter. The scoop design is obvious. The cover cannot be removed, only broken despite the screws that have been loosened. After 2 years, the water stopped flowing and poured into the drainage. But the filters cost a decent 3 thousand. rub per set. Here you are all right.

Image - Aquaphor dwm 101 morion DIY repair

+ MrLekarstvo, hello.
We do not recommend carrying out unqualified repairs or modifications to our filters on your own. Please contact customer service or consult by phone with a call center specialist at the phone number listed on the website

Image - Aquaphor dwm 101 morion DIY repair

That is, you want to say that the new filter clogged so much in 4 days that the pressure dropped? And this is in the presence of a main filter, which was replaced 2 weeks before. And the original filter worked for 4 months without any problems. They sent me a photo of the filter and, judging by the photo, it was initially not quite normal.

Image - Aquaphor dwm 101 morion DIY repair

+ Aquaphor - Water Filters I don't understand what you are talking about. The entire verification procedure took place in my presence. Found out that the problem was in the precleaner module. IN A NEW module. Which stood for only 4 days. We have a city water supply system. There is a filter at the entrance to the apartment, a mesh. Plus there is a 10mk main filter. What kind of muddy water? I can send you a photo of what your specialists got from the module. The question is rather a defective module.

Image - Aquaphor dwm 101 morion DIY repair

Hello,
The filter has passed diagnostics and no defects were found.
A specialist on site discovered that a prefilter was standing upstream. If new cartridges are incorrectly rinsed in cloudy water, even a new filter can be damaged quite quickly.
The cartridges included in the kit could work for 4 months due to less wear on the pre-filter cartridge that Alexey had.

Image - Aquaphor dwm 101 morion DIY repair

This video does not flush the modules using the service plug. Is it not necessary? And further. The instructions indicate the diameter of the drainage hole is 7 mm, in the video it is suggested to use a 6 mm drill. And the instruction itself is poorly written. For example, it is suggested to do a flush with a service plug BEFORE connecting the pipes to the filter. What raises the question of believing the clumsy written instructions or this video?

a. Flushing of filtering block modules.

1. For this we need a flushing plug, which will prevent coal dust from entering the reverse osmosis membrane.

The plug is located under the top filter cover. To get it, you need to turn the latches on the cover of the water purifier by 90 degrees and remove it. For the convenience of servicing the filter, the locking buttons on the body of the water purifier have a different color - in accordance with the purpose of the module used:

For the operation of the water purifier:

black - for the K5 pre-treatment module;

2.To operate in the “filter washing” mode, it is necessary to remove the heat-shrinkable film from the filter modules, remove the transport plugs (if any) and install the modules in the following order:

To flush cartridges:

In the socket with a black stop button - module K2;

Before inserting the module into the slot, make sure that the inner surface of the connecting flanges of the block-modules is free from traces of coal dust, etc. If so, rinse the flange under running water. Insert the appropriate block-module into the corresponding slot of the manifold as far as it will go and turn clockwise until it clicks. (To remove the block-module, you need to hold the locking button located above it and turn the block-module counterclockwise until it separates from the case).

4. Open the tap for clean water at the sink and run the water through the filter for 10 minutes.

5. Close the tap for clean water at the sink and leave the filter in this state for 10 minutes.

6. Open the fresh water tap again and run the water through the water purifier for 40 minutes. The rinsing of the filter modules is complete.

b. Flushing the tank and reverse osmosis membrane:

1. Connect the membrane to the water purifier as indicated in the instructions: to do this, remove the clip from the fitting at the bottom of the membrane module and insert the elbow of the tube into the plastic sleeve until it stops. Then put the clip back on.

2. Insert the block modules in the order indicated in the section “For the operation of the water purifier”.

3. With the inlet valve open and the clean water valve closed, make sure the filter is tight. In this position, the water purifier is started up.

4. After filling the tank for the first time (water from the drain tube will stop flowing), open the clean water tap at the sink and drain all the water from the storage tank.

5. Fill the tank a second time and drain the water again.

It is not recommended to drink the water obtained as a result of the first two washes.

6. Fill the tank a third time and use clean water. Depending on the water pressure in the mains, this procedure can take up to 4 hours.

It is also necessary to flush the system every time you replace the filter elements. If you have not used the filter for more than a week, drain the remaining water in the tank and refill it with fresh.

If you only change the pre-cleaning unit K5 (expanded polypropylene) you do not need to flush the modules.

When installing the equipment by a specialist of the company, he will also flush the system.