In detail: ariston abs vls pw 50 DIY repair from a real master for the site my.housecope.com.
Using any water heater, and Ariston is no exception in this case, it is necessary to carry out regular descaling. In order for the unit not to fail in advance, it is recommended to clean it once every six months, and replace the magnesium anode once a year or two. All this can be done with your own hands, and this has already been described earlier in the article "Why and what is a magnesium anode in a water heater for". But before starting to carry out cleaning activities, it is worth learning how to disassemble the Ariston water heater.
These are the minimum preventive measures that you can do at home with your own hands and without the use of special equipment. Of course, when a heater, a thermal sensor fails, or other serious problems arise, you should not risk it and it is better to turn to professionals. The rest - everything depends only on you.
Not only home owners provide themselves with autonomous hot water. More and more residents of apartment buildings prefer to install flow-through or storage water heaters. There are 2 reasons for such unconditional popularity - interruptions in hot water supply, especially in the off-season, and the high cost of hot water supply.
For several years, the Italian boilers Ariston have been popular. They are of high quality, reliability, long service life, if used correctly. Nothing eternal has yet been invented, and therefore repairs sometimes have to be done on their own.
And although a water heater is a rather complex device, its regular cleaning and maintenance can be done independently in just a couple of hours. The main thing is, before starting the actual work, understand not only how the equipment works, but also how to disassemble it correctly.
Video (click to play).
The most important thing is to completely drain the water from the boiler. On the lower part there are 2 nozzles, one of them enters the boiler, and the other is drained.
Even after the water is completely drained, some of it remains at the bottom of the tank, so place a bowl for the rest before opening the lid.
Since a high-quality drain is the key to the successful outcome of the entire operation, we will dwell on it in more detail.
The procedure depends on the features of a particular model - with a trigger, tee or by means of a check valve.
the most whimsical model is considered to be one in which a fitting tee is built between the pipe and the valve. He will have to unscrew it with an adjustable wrench and drain all the water.
on those models where there is no tee, but there is a trigger - a jumper on the return valve. You can bend it, fix it and wait for all the water to drain. This process usually takes 1.5-2 hours.
the simplest and therefore most effective way is to unscrew the check valve counterclockwise. Before that, connect the hose to the water outlet and drain.
If, during any manipulations, water does not flow from the return, open the hot water tap to create the necessary air flow, and do not close it until the boiler is empty.
Attention! All work is carried out only after the water heater is disconnected from the power supply!
For those who have no time to read, we have prepared a video instruction on how to disassemble an ariston water heater. Here you will learn about the features of installation, connection to pipes, cleaning, etc.
screwdriver;
pliers;
knife;
a water drain hose that matches the diameter of the return pipe;
replacement anode;
a special agent for cleaning heating elements, you can also use a concentrated solution of citric acid.
We repeat once again, all work on the disassembly of the water heater is carried out only when it is completely de-energized.
The device does not heat up the water - if you are convinced that the outlet is working and there is electricity, the malfunction lies in the heating element.
The water heats up very slowly - the magnesium anode must be replaced.
During operation, a distinct but dull hiss is heard - excessive scale and deposits on the heating element.
How to properly clean the heating element from scale - video specialist:
A feature of Ariston water heaters is the presence of an oval-shaped flange.
disconnect the boiler from the network;
drain the water through the return pipe;
remove the cover from the bottom of the unit;
carefully pull out the thermostat so as not to damage the gasket;
an oval flange is accessed.
Before starting to pull out the flange, it is necessary to unscrew the nuts on the strip, remove it, pull out the heating element with a scrolling motion, and only then remove the flange. Otherwise, it will not work.
In order to replace and correctly install the flange, take a photograph of its position in the neck of the water heater in advance. Otherwise, water will constantly leak.
Be sure to change the gasket! It should be of high quality, preferably a branded product, designed for 2 years of continuous operation.
After the flange and gaskets have been replaced, the electrical block, internal components, heating elements are cleaned with a sponge, and the magnesium anode is replaced if necessary.
The assembly is carried out in the reverse sequential order so as not to violate the structure and to prevent its failure.
The range of products includes medium class water heaters with improved functional characteristics. The main design feature is that here the flange is bolted in the amount of 4-6 pieces.
disconnect the device from the network;
drain the water;
remove the cover from the bottom of the case;
disconnect the wires from the heating element and unscrew all the nuts;
slightly pressing the heating element inward with a slight scroll, pull it out - clean or change;
unscrew the nuts on the bar and take out the flange;
change it and the gasket.
For those who are used to solving problems on their own, it will not be difficult to disassemble the Ariston water heater and carry out its prevention. By and large, there is nothing difficult in this operation, only diligence and strict adherence to instructions are required. Record all actions carried out with the device in order to subsequently collect everything exactly the opposite.
A simple and temporary solution to repair a water heater at home. The battery lasts for an hour.
Buy spare parts for water heaters Ariston ABS Velis Power 50 V at a low price here: Buy spare parts.
My site Electrician ❤❤❤Educational and educational channel for children! ❤❤❤ ➥➥➥https: //youtube.com/channel/UC6hSiEv9t_j.
Repair of the electronic module of the Ariston water heater. The water heater is not working. The display is off. Not reacting.
Buy spare parts for water heaters Ariston ABS Velis Power 50 V at a low price here: Buy spare parts.
I created this video with the YouTube Video Editor (https://youtube.com/editor)
- cashback for any purchase at Aliexpress! - save more than 800 magicians.
Water heating tank. Replacement of the anode, gaskets, descaling of heating ten. Didn't help, myself.
Replacing an electronic thermostat with a mechanical one in water heaters Ariston ABS PRO SLIM - spare parts.
cleaning the water heater Ariston ABS VLS EVO PW 50.
We are repairing the power module from the Ariston boiler. The reasons for the breakdown and their correction. Repair Forum:
Boiler ARISTON PRO ECO 100 V DRY HE - How to descale. Preventive cleaning of the water heater.
Replacing the standard 5V power supply with a charger from a mobile phone.
descaling the ariston boiler.
Such a heater came in for repair! After looking on the Internet, a lot of people ask for help, but before.
We just decided to clean the water heater.
In this video I will try to describe the process of repairing a water heater with my own hands. Breakage is enough gray.
User review. Main advantages and control of the water heater.
The device is connected to the network, but the indicator light of the heating element does not light up, and the liquid is not heated. You can determine the breakdown in the following ways.
It is necessary to take a tester, set it to the position 220-250 V, measure the voltage at the terminals connecting the cable to the thermostat, if there is a signal, we measure the potentials at the terminals of the heating element. If the indicators are normal there, then the heating element is broken directly.
We turn off the storage water heater from the network, set the measuring device to the ohm resistance measurement scale,
then we disconnect the heating element from the thermostat and release the wires from the terminal so that the contacts of the heating device are exposed. We measure the value of resistance (Ohm) in the contacts of the heating device, if it is working properly, a certain value will appear on the screen, the figure is not so important in this case.
If it does not show any value, you need to purchase a new one, since this one is faulty and not suitable for repair, it is recommended to replace the flange seal and the anode at the same time.
And now we will describe in more detail how to remove the heating device from the boiler with our own hands:
De-energize the boiler and shut off the water supply from the mains.
Unscrew the bolts from the cover plate and remove it.
Disconnect all wires.
Unscrew the bolts that fix the heating element, there are usually 6 of them.
Pull out the heating element with a rotary motion.
Clean the tank and replace the necessary parts.
Assemble everything in reverse order; it is recommended to tighten the bolts evenly.
The next malfunction in the Ariston water heater for 50 liters may be a breakdown of the thermostat and thermostat.
Boiler thermostat
Possible thermostat malfunctions:
The copper tube is worn out.
Insufficient connection of contacts.
Electronics malfunction.
Accumulation of plaque.
Malfunction resulting from voltage surges.
One of the indicators of a malfunction is the failure to turn on the heating element when there is operating voltage and water in the tank. To check its performance, you need to get it out, this can be done by disconnecting the power cable and wiring in the electronic board. Then remove the thermostat very carefully.
Then you need to take a tester, set it to measure the voltage. We move the regulator relay to the maximum position, measure the thermostat contacts. If there is no reaction, it is broken, you will need to buy a new one or make a repair and install it in place.
In the event that the control thermostat has triggered, then the following steps must be performed. We set the minimum position of the thermostat and fix the measuring device on the contacts.
We take a lighter or a candle and heat the thermostat flask. If it is a worker, then the relay will operate and the circuit will open, and the resistance will tend to infinity.
Take it out, drill out the copper rivets that hold the body together, then separate the stem and body, doing this as carefully as possible so as not to damage anything.
Strip the bimetallic plates. If they are not strongly oxidized, you can clean with a small piece of cloth dipped in alcohol, put the cloth on the bottom plate and rub. If this does not work as desired, use a fine abrasive paper.
If the opening contact or, as it is also called, the rocker is stuck to the body, it is necessary to disconnect the contact and clean this area. The contact in the working position returns to the upper position independently.If this is not the case, pull it out, clean it, also clean the place of its installation and reinstall it. Bimetal thermostat plates
Install the stem in its original place and fix with self-tapping screws.
Most often, this breakdown occurs if the boiler is turned on without a tank filled with water, or its service life has expired.
The next equally common problem is leakage. There are two possible sources of such a breakdown: a breakdown in the tank or a flange leaking.
In the event of a tank leak, it makes no sense to carry out repairs, since replacing it will be very expensive, another thing is if the Ariston water heater is still under warranty, then you have the opportunity to return the device.
And if the flange is the cause of the leak, there will be no difficulty in fixing the breakage. It is necessary to drain the water, remove the gasket, go to the store with it and purchase a similar one. Then make a replacement and that's it.
Then consider such a breakdown as the lack of electricity supply to the device. Again, we check with a tester or a special indicator screwdriver if there is a signal in the cable on the phase. Below is a diagram of an electric water heater.
If you need to replace the cable, you must purchase it with the same characteristics as the one that failed. When installing, insert it into the desired hole and connect to the terminal block. If the wire turns out to be in good condition during the check, check the tightness of the connections with the plugs.
The socket where the device is connected may also be broken, to make sure that it is working properly, connect another electrical device to it. Your outlet may be rated for less power.
During a power surge in the network, the RCD turns off the device, this may also be the cause of malfunctioning. Check the serviceability of the RCD itself using the test button on it.
We bring to your attention a video about the repair of the power module of the Ariston boiler:
The Ariston Academy names the main mistakes of connecting an electric storage water heater, because of which the tank is in danger. Replacing the original valve with an average check valve, completely excluding the specified element from the piping. In order not to repair the Ariston water heater with your own hands on an ongoing basis, as well as buy an Ariston water heater with your head, over and over again, know a couple of simple rules, which we will talk about in between below. The features of Ariston water heaters are limited by the lack of flow models. Everywhere there is a magnesium anode, the tank is made of steel. It is useful to remember when repairing an Ariston water heater with your own hands is pecking.
Today we will consider the repair of the Ariston storage water heater. Electric, but most positions are suitable for gas. There are half a dozen errors in connecting a storage water heater, thanks to which the owner notices: the tank began to cry. When cleaning the heating element, you can see: the enamel coating peeled off, the tank is rotten, the stainless steel seams leaked!
When cleaning the storage water heater, you should tackle the heating element and the walls of the tank. The matter is aggravated by the fact that there is no normal hole for the repairman to carry out service operations, it is simplified by the fact that the heating element is easily or difficult to remove outside, the anode salts more resemble mucus than stone calcium carbonate. As a result, remove the heater carefully, you risk getting dirty with liquid pouring from the hole. It is difficult to empty the reservoir 100%.
Most storage water heaters are of vertical design. Bottom removable panel. There is a construction that pleases the repairmen with its simplicity:
From one to six bolts (nuts) securing the heating element.
Half a dozen wires for the following purpose:
Land.
Phase.
Zero phase (neutral).
The first, the third is formally one. The subtle difference is of interest exclusively to electrical engineers; in the absence of human grounding in the house, it can be short-circuited temporarily.A thermostat with a probe is inserted inside the heating element of the storage water heater. We'll have to pull it out by pulling the heater out. Most often, there is a relay inside the thermostat that is triggered when the measured medium reaches a certain temperature. For example, a traditional bimetallic plate.
The limescale of the heating element is removed by citric acid. The reagent is used as part of complex anti-scale agents even for industrial boilers and utilities. The concentration is taken as 4.5%, the temperature is above 45 ºС. At night, a two-liter bottle is filled with a solution, a heating element is placed.
In the morning, you can remove the remaining limescale relatively simply. Videos often show how large pieces are cut with a knife. This makes sense, there will be more active solution for the volume of the remaining scale. The heating elements are cleaned with acetic acid, hydrochloric, sulfuric. It is allowed to use store-bought descaler in household appliances. Whichever reagent is used, remove the rubber pad. The part will rapidly age in the solution, and will become unusable faster.
The insulation resistance between ground (usually the middle terminal) and any contact is 24 MΩ. The coil resistance of the storage water heater is determined based on the power. The passport of the device is taken, the desired parameter is selected in the technical characteristics section, Ohm's law will allow you to calculate the desired value. Power is related to voltage, resistance by the following expression:
P = U 2 / R, the expression will serve the purpose of calculating the resistance R.
For every kilowatt, there are 13.5 ohms. The power of the water heater is 2 kW, the coil resistance is 27 Ohm. The outer copper tube rings with the ground. Another factor: if the heating element looks good, check if the shell is broken. It is easier to do, taking salt water, immerse the heating element so that the contacts do not get wet, measure the resistance between the solution, any end of the spiral. Will come out 24 megohms (on the screen of a cheap tester you will see "infinity").
Fact means a short circuit to the storage water heater case, the riser will not appear after switching on. Water conducts a current, which means there is a small chance of potential arrival at the bathroom mixer, will be waiting for the victim. The devices of the bathroom, toilet room are protected by a differential protection device. At the slightest leakage current, it will cut the circuit. The principle of operation is simple: the difference between the input and output currents is measured. It is not superfluous to put a fuse that protects the spiral from combustion. Done if the differential protection device lacks the appropriate slots. In the event of a short circuit of the coil, the protector may burn out from the leak!
Often, self-repair of Ariston water heaters is faced with the need to clean the tank. Some even do it with a grinder ... It's incredible. No hard objects inside! Just a cloth, hands, soap. Place the water heater upside down at night, pour citric acid solution (5 liters) through the hot water pipe. Muffle the inlet (not the outlet through which the solution was poured), put the water heater off. Please note: the rubber pad is not fitted for the above reason. Place the storage water heater where the leakage of a small amount of liquid will not cause irreparable harm.
Please note: the warranty repair of Ariston water heaters does not cover damage to the tank by hydraulic, mechanical shock. The thickness of the steel is low, do not neglect the simplest installation rules. Non-return & bypass valve, apartment water hammer damper in the first place. The magnesium anode must be changed without fail.
The fact is that the copper heating element of the storage water heater creates a galvanic pair with steel, and this will lead to damage to the tank. The situation will worsen if there is a small scratch. In this case, the area of the donor is much smaller than the acceptor, so corrosion will develop shock-fast.But to fix the tank, you will have to cut off the top, or remove the thermal insulation, cook outside. Believe me, in both cases, the owner will be happy to buy a new storage water heater Ariston, unless the product costs more than 10,000 rubles.
A storage water heater is an indispensable addition for lovers of comfortable bath procedures. During the night, 2 kW can easily heat 100-200 liters of water to a temperature of 70-80 degrees Celsius. In the morning, the couple will fill 2 baths by mixing hot and cold jets.
Today, various types of heaters have become very firmly established in our modern everyday life. Specialized stores offer products from well-known world brands, such as Ariston, for example. Despite the high reliability, any household appliances can fail over time for any reason. In this case, it will be useful to know how to carry out an independent repair of the Ariston water heater.
In the mid-40s of the last century, Aristide Merloni launched the production of electric water heaters under the Ariston brand (Successful). The name fully justified itself, and after a while all the sons of the entrepreneur successfully entered a similar business, and the youngest, Vittorio, inherited his father's company.
The Ariston company today is one of the three leaders in terms of global sales of household appliances, and Ariston brand kitchens are sold with already built-in basic household appliances from a refrigerator to a dishwasher. In Russia, this company became famous at the end of the 90s of the last century, and now almost every large city has its service center.
Ariston water heaters have a stylish modern design, excellent functionality, differ from analogues of other manufacturers by a reasonable price. Developers pay reverent attention product safety during operation: the units are equipped with various protections for all occasions, which switch off the product in the event of a power failure, overheating, or no water supply.
But this reliable technique suffers from the hardness of our water and the rather frequent drops, surges in voltage. The weakest points, according to experienced craftsmen, are tubular heating elements, a magnesium anode and a check valve. These very simple breakdowns can be eliminated with your own hands if you have the necessary minimum of tools. The design of the product has a standard scheme, so prevention and repair is not difficult.
The user should pay special attention to the integrity of the inner coating, where modern materials are used, which include titanium, silver strengthening enamels, glass ceramics and other high-tech additives.
Before disassembling the Ariston water heater for repair, it is necessary to study the design of the product, prepare the necessary tool, as well as various devices. To repair mechanical damage, such as water leakage, you need:
a set of keys or one small adjustable wrench;
a set of various adapters;
new non-return valve.
In the event of malfunctions with the electrical part, it is necessary to prepare multimeter.
Preparation also includes such work: disconnecting the device from the home electrical network, draining water from the tank.
The tank in the Ariston water heater consists of the following main components:
A heating element.
Thermostat - designed to control the set temperature, as well as to adjust the heating mode.
A relay that controls the switching on or off of the heating element.
Special anode - it protects the inner coating from corrosion.
Safety valve - regulates the internal pressure when heating water.
Signal lights in budget models (they should turn on when power is applied) or electronics for more expensive products.
The home craftsman should study the instructions in detail before starting prophylaxis or minor repairs in order to navigate freely.
According to statistics, during the operation of the Ariston boiler, the following typical malfunctions may appear:
no water heating - heating element burned out;
thermostat replacement required;
the magnesium anode has completely used up the assigned resource;
a large layer of limescale from the heating elements has formed.
In the event of these malfunctions, in addition to the second option, you need a complete disassembly of the product.
There is absolutely no difference what volume you have an Ariston water heater - 50 or 100 liters, the dismantling process will be identical.
Water heater thermostat Ariston
Every owner of Ariston water heaters should know that when replacing a thermostat, relay and safety valve no need to dismantle the tank.Water draining and complete disassembly of the boiler is carried out only during maintenance work and when replacing a burned out heating element.
Disassembly of the product is divided into standard steps:
Disconnect the water heater from the household power supply.
Drain the water tank.
Dismantle the flanges, access the inside of the water heater.
Before disassembling the product, you must make sure that it disconnected from the network: if the heater is powered by a separate line, then it is necessary to turn off the circuit breaker, if just through the cord, then simply unplug the plug.
Some readers may wonder: why emphasize these points so often? But statistics claim that during home repairs or when burnt-out parts are replaced, very often craftsmen who neglect safety precautions receive electrical injuries of varying severity.
Only after de-energizing, you can begin to dismantle the Ariston boiler with your own hands:
unscrew the cover, which is fastened with screws;
before starting dismantling, take a picture of the location so as not to confuse anything during assembly;
disconnect three-core cable, the first two wires - phase and zero were connected to the thermostat, so you can carefully remove it.
All work on the electrical part has been successfully completed, you can start draining the water from the tank.
If the initial installation of the water heater was carried out by a master from the service, then he should have installed special tee with a drain cock and screw the fitting into it. Quite a handy device - the user easily connects the hose, as shown in the photo, and drains the water into the bathroom. In the absence of a special device, water is removed by connecting a hose directly to the product's branch pipe.
Need to know! To balance the external and internal pressure, open the hot water tap.
Draining the water can take several minutes, if the capacity of the heater is up to 50 liters, and when you have Ariston for 80 liters, the wait will drag on for up to 30 minutes or more.
All modifications of products under the brandAristonhave an oval flange on which the shades are installed, a magnesium anode and a tube with a thermostat inside... Put on the flange body from below elastic rubber pad to ensure tightness. The flange is fixed with a U-shaped bar, which is fixed with a nut.
We unscrew the nut, carefully push the flange inward, turn it and remove it outward. Further, the failed parts are replaced and the surfaces are cleaned from salt and lime deposits.
Attention! Efforts must not be made when cleaning the boiler tank: over time, it becomes thinner due to the effects of corrosion. When carrying out preventive maintenance, it is advisable not to clean thin scale.
Remove excess debris at the bottom of the tank, visually inspect the rubber seal, if everything is in order, then do not change it - it is very expensive, and it is very difficult to get a new one. Dismantling and subsequent assembly can be done independently by any user without special training. We attach this video to help:
The operating statistics of similar heaters allows us to conclude: regular inspections of the wear of the magnesium anode, cleaning the heating element, prevention of the inner lining of the tank must be done on a regular basis, this will significantly extend the life of the product.
Many models of water heaters are equipped with an electronic display on which different error codes... You can decipher them using the instructions. Visually, the user can identify the following malfunctions:
the product does not turn on - the circuit breaker has tripped;
the water is very hot - the thermostat has burned out;
drips form at the bottom of the tank;
if when the product is turned on, the plug heats up - this is a signal that the power of the outlet is low.
Some users do not suspect that the boiler may not turn on for a reason burning contact in the socket, which indicates its low power or lack of grounding.
Any failure of reliable household appliances can provoke the following reasons:
The formation of a large amount of scale on the heating element.
Voltage surges in the electrical network contribute to electronics failure.
Reduced water flow due to clogged filter and non-return valve.
To reanimate the equipment, you will need spare parts, cleaning the heating element and flushing the inside of the tank.
Advice! In order for any brand of equipment to serve for a long time and properly, do not set the temperature above 60 0 C - this significantly reduces the process of scale formation.
Repair of water heaters Ariston ABS VLS PREMIUM PW 100
Error codes for the water heater Ariston ABS VLS PREMIUM PW 100
Internal malfunction of the main board.
Restart the water heater by pressing the ON / OFF button. Check the main board for condensation. Replace the main board.
Open or short circuit of the NTC1 / NTC2 temperature sensor - the leaving tank of the water heater.
Restart the water heater by pressing the ON / OFF button. Check temperature sensors for condensation. Check the NTC1 / NTC2 temperature sensors for open / short circuit and (if necessary) replace the temperature sensor.
Overheating of water detected by a separate sensor (more than 105 ° C) - leaving tank of water heater
Restart the water heater by pressing the ON / OFF button. Remove limescale and salt deposits from the heating element. Check that the heating element is working and (if necessary) replace the heating element. Check the operation of the NTC1 / NTC2 temperature sensor and (if necessary) replace the temperature sensor.
General overheating. The average temperature of the NTC1 / NTC2 temperature sensors is higher than the set one by 12 ° C - the leaving tank of the water heater
Restart the water heater by pressing the ON / OFF button. Remove limescale and salt deposits from the heating element. Check the operation of the NTC1 / NTC2 temperature sensors and (if necessary) replace the temperature sensor
Touch differential error. The difference between the readings of the NTC1 / NTC2 temperature sensors is more than 50 ° C - the leaving tank of the water heater
Restart the water heater by pressing the ON / OFF button. Remove limescale and salt deposits from the heating element.
Check the NTC1 / NTC2 temperature sensors for condensation. Check the NTC1 / NTC2 temperature sensors for open / short circuit and (if necessary) replace the temperature sensor. Check that the heating element is working and (if necessary) replace the heating element.
Low heating rate of water - leaving tank of water heater
Check the mains voltage. Check that the heating element is working and (if necessary) replace the heating element. Check the operation of the NTC1 / NTC2 temperature sensor and (if necessary) replace the temperature sensor. Remove limescale and salt deposits from the heating element.
Lack of water - leaving tank of water heater
Switch off the water heater by pressing the ON / OFF button. Fill the water heater with water. Check that the safety valve is working and (if necessary) replace the safety valve. Check for the presence of the hot water pick-up tube in the outlet tank. Remove limescale and salt deposits from the heating element. Switch on the water heater by pressing the ON / OFF button.
Open or short circuit of the temperature sensor NTC1 / NTC2 - incoming tank of the water heater
Restart the water heater by pressing the ON / OFF button. Check temperature sensors for condensation.
Check the NTC1 / NTC2 temperature sensors for open / short circuit and (if necessary) replace the temperature sensor.
Overheating of water detected by a separate sensor (more than 105 ° C) - incoming water heater tank
Restart the water heater by pressing the ON / OFF button. Remove limescale and salt deposits from the heating element. Check that the heating element is working and (if necessary) replace the heating element. Check the operation of the NTC1 / NTC2 temperature sensor and (if necessary) replace the temperature sensor.
General overheating. The average temperature of the NTC1 / NTC2 temperature sensors is higher than the set one by 12 ° C - the incoming tank of the water heater
Restart the water heater by pressing the ON / OFF button. Remove limescale and salt deposits from the heating element. Check the operation of the NTC1 / NTC2 temperature sensors and (if necessary) replace the temperature sensor.
Touch differential error. The difference between the readings of the NTC1 / NTC2 temperature sensors is more than 50 ° C - the incoming tank of the water heater
Restart the water heater by pressing the ON / OFF button. Remove limescale and salt deposits from the heating element. Check the NTC1 / NTC2 temperature sensors for condensation. Check the NTC1 / NTC2 temperature sensors for open / short circuit and (if necessary) replace the temperature sensor. Check that the heating element is working and (if necessary) replace the heating element.
Low water heating rate - water heater entering tank
Check the mains voltage. Check that the heating element is working and (if necessary) replace the heating element. Check the operation of the NTC1 / NTC2 temperature sensor and (if necessary) replace the temperature sensor. Remove limescale and salt deposits from the heating element.
Lack of water - incoming water heater tank
Switch off the water heater by pressing the ON / OFF button. Fill the water heater with water. Check that the safety valve is working and (if necessary) replace the safety valve. Check for the presence of the hot water intake tube in the inlet tank. Remove limescale and salt deposits from the heating element. Switch on the water heater by pressing the ON / OFF button.
my.housecope.com/wp-content/uploads/ext/2255
Posts: 3695
Did you smoke an ABC book in due time, or what? Reading you is hard and not pleasant. You can't do it yourself, there are enough browsers with spell checking capabilities.
q0209And why should all this be poured into the exchanger? Especially crookedly photographed not edited and at this size? Here's an example of your 2.7 MB file. Is it really so hard to get it right? After all, such actions only make it worse for yourself.
The Ariston water heater is designed according to the latest technologies, has not only a high-quality water heating tank, but also good technical characteristics. The main advantages of such a boiler are durability and reliability, intuitive control and convenient operation. Each device must be complemented by a detailed instruction manual, which allows you not only to independently install and connect the water heater, but also to perform simple repairs with your own hands.
Ariston produces more than seventy models of storage water heaters with a capacity of 10-200 liters. The electric storage water heater is presented in several models, among which the 50.80 and 100 liter series are especially popular.
Heating time up to 45 ° C (min)
ABS PRO ECO INOX POWER SLIM
Ariston "Velis" - water heaters with remote control and double power, with a flat shape and changeable color displays, have proven themselves very well.
The cost of gas equipment depends on the principle of the hot water device and its type. Each boiler is designed in the same way, but it also has some features:
DGI water heaters have electronic ignition and manual regulation of power indicators. Natural removal is characteristic. The gas water heater has a laconic rectangular shape;
Fast-CF does not need additional power supply, and copper is used for the manufacture of the heat exchanger, which can significantly reduce heat losses;
Marco-Polog7s features a closed combustion chamber, which provides additional operational safety. There is a touchscreen display and modern design, which makes the model the most popular with consumers;
Marco-Polo М2 is a model with an open combustion chamber and a fan for smoke extraction. There are a couple of stages of protection of the device, preventing overheating and guaranteeing high safety indicators, as well as a long service life.
Before installing the device, you must familiarize yourself with the principle of operation of the Ariston water heater, as well as study the instructions with detailed instructions on the individual characteristics of the installation.
The manufacturer uses proprietary protection against corrosive changes. Absolutely all budget models are equipped with a mechanical regulator, and each expensive water heater is equipped with a digital control unit. An internal temperature controller works inside the water heater to optimize heating. The device and principle of operation of such equipment are as follows:
an internal tank or boiler designed for cold water intake and framed by an external casing.
built-in heating element designed to heat the incoming water;
a heat-insulating layer located between the body of the water heater and the boiler, which serves as a kind of thermos and allows maintaining the temperature indicators of heated water for a long time;
a shortened branch pipe equipped with a divider for the water supply;
outlet pipe;
built-in magnesium anode to prevent heavy deposits in the form of mineral salts on the walls of the inner surface of the tank.
a thermostat designed to automatically interrupt the power circuit after heating the liquid to the specified temperature values.
The operation of hot water equipment is monitored by means of a voltage indicator, and with the help of a built-in thermometer, changes in temperature indicators can be monitored.
Convenient connection of hot water equipment from the company "Ariston" is the use of manufacturers of autoclave special flange mechanism. The basic principle of this mechanism is based on pressing the gasket under the influence of water pressure. As a result, it is possible to completely eliminate not only fluid seepage, but also the formation of watery smudges. To avoid unnecessary heat losses, the electric models of the Ariston water heater are fixed in close proximity to the outlet point.
For the installation of wall models, the equipment is fixed with anchors or bolts. The optimum standard diameter of the fastener should be 10 mm or more.... Installation of stoliter water heating tanks has some peculiarities. In this case, the fastening must necessarily take place with fixation on the other side of the wall.It is for this reason that experts recommend installing water heating devices before starting the main finishing work.
Important to remember, that when connecting different types of metals, it is imperative to use dielectric adapters, by means of which differences in the degree of expansion of materials differing in parameters are compensated. It is necessary to connect the input using a standard valve, and a branch pipe is installed on the output. At the final stage, the installed water heater must be turned on and checked for correct connection, absence of leaks and operability.
During the operation of water heaters produced by the company "Ariston" difficulties do not arise, but it is necessary to take into account some rules that affect the durability of the device and its performance. Preventive measures are carried out periodically, including inspection of the internal parts of the equipment, descaling and replacement of a deteriorated heating element. The average operating time of all mechanisms of a particular model can be found in the manufacturer's instructions. It must be remembered that the timely implementation of the anode replacement allows you to extend the service life of the water heating mechanism.In accordance with the recommendations of professionals, it is not advisable to set the thermostat to the maximum heating level.
If the temperature limit is set by about 10 ° C below the maximum values, then it is possible to significantly reduce the consumption of electrical energy, as well as save the resources of equipment parts. It is important to remember that you can only disassemble the device yourself as a last resort. Do-it-yourself repair work will exclude the possibility of using the right to warranty repair.
Repair work related to the elimination of breakdowns in gas appliances requires the involvement of qualified specialists, and the repair of an electric boiler can be performed independently.
Major mechanical failures are most often manifested by tank leaks.from which water begins to ooze or drip during operation. The cause of such a problem can be corrosion in the areas of the welds or a malfunction of the reverse protective system of the valve, which is triggered and performs an emergency reset. In this case, it is necessary to eliminate the excessive level of water and air pressure by means of a reducer. Any depressurization of the storage tank will require the purchase of a new tank. If such a defect is minor, then it is sufficient to replace the sealing gasket.
A fairly low-cost measure is the independent replacement of some electrical parts, including heating elements, a bimetallic thermostat, sensors or switches. In case of prolonged heating, noise or hissing, as well as in case of activation of the ABS system shutdown protection, it is necessary to replace the heating element, the average service life of which does not exceed five years. Replacement is carried out after de-energizing the device, draining the water and removing the flange.
It is very important to systematically check the magnesium anode, which is a consumable item and is designed to effectively protect the inner surface of the tank and heating element from corrosive changes. When the anode becomes thinner by ½ of the initial volume, a mandatory replacement is carried out. The heating element can last much longer if the so-called "dry" heating element is installed in the structure.
Video (click to play).
Ariston, a well-established manufacturer in the market of water heating equipment, has been holding a leading position for a long time and offers the consumer only high-quality and very reliable products in a wide range.And the presence of the largest network of service centers in many cities of our country allows you to seamlessly receive qualified assistance, both in repair work and in the maintenance of water heating equipment.