In detail: geyser neva 4512 DIY repair from a real master for the site my.housecope.com.
Warning. This section is intended for specialists who have the appropriate permission to repair gas equipment! If you repair yourself during the warranty period, the warranty is void!
This article will focus on malfunctions of Neva speakers (models 4510, 4511, 4513, 4510M, 4513M, 4610, 5611). Many Chinese speakers, for example Vecktor or Oasis, and not only Chinese ones, work on the same principle as the Neva, so the remedies below apply to them as well. But, please be more careful, the photographs in the article show details for the Neva columns.
No spark when hot water is opened.
When the hot water tap is opened, there is a spark discharge, but the column does not ignite.
Check if the hot water tap in front of the column is open.
There is no gas in the main gas pipeline. You need to call the service to fix the problem.
Check the serviceability of the EMC. Connection contacts may be broken.
Correct the spark plug, it is possible that the discharge does not reach the flow of the gas-air mixture (about 5 mm from the end of the plug to the burner).
When using a column from liquefied gas, it is necessary to check the gas supply in the container (cylinder).
Weak spark from spark plug electrode. It is required to clean the contacts of the battery compartment or to completely replace the ignition elements (batteries).
The column will run for a while and turn off.
Poor cravings. Thrust sensor triggering. It is necessary to clean the chimney or check the tightness of the exhaust pipe connection on the column pipe.
Overheating of water (outlet water temperature is more than 90C, triggering of the limit temperature sensor). It is necessary to use the column control knobs to reduce the gas consumption and increase the water pressure.
Replace the membrane of the water unit.
There is no signal from the ionization sensor (flame sensor). In this case, the burner works for no more than 7 seconds, and spark discharges from the spark plug do not stop. It is necessary to restore contact with the sensor, correct its position (if it touches other elements of the burner) or replace it.
Video (click to play).
The water temperature reading is not shown on the column display.
Defective water temperature sensor. It needs to be replaced.
Check the connection contacts of the display itself to the ignition unit. If there is no result, replace the display.
The water does not heat up well.
Reduce water pressure.
It is required to check the heat exchanger for the presence of scale on its walls. If necessary, remove it, rinse with Solita. It is also necessary to clean the column burner from dust and soot on its surfaces.
Insufficient gas pressure in the line - call the service to eliminate the causes.
Repair or replacement of the water unit is required.
The flame of the burner of the column is yellow and weak, with smoky tongues.
1. It is necessary to clean the column burner from dust and soot on its nozzles and internal surfaces.
Excessive noise of water during the operation of the column.
It is necessary to reduce the water pressure with the column adjustment knob.
Extrudes gaskets at the joints of the water pipes. Replacement of gaskets is required.
The burner continues to operate even when the hot water tap is closed.
The stem of the gas unit is seized (it is very difficult to move the stem manually). It will be easier and safer to replace this unit.
It is required to replace the membrane of the water unit.
These were the most common malfunctions of the Neva speakers. We hope this article helped you troubleshoot your water heater.
the wick burns very strong during the night heats up the pipes with water when the water is opened after a few seconds there is boiling water for the daughter-in-law of the children sprinkles when they wash their hands the plastic tubes of the teapot how to reduce the wick
Hello, tell me the model of the column.
remove the front cover and on the gearbox you will see a yellow bronze screw for a screwdriver. twist it smoothly while the wick is working.
WHY WHEN THE WATER REGULATOR IS ADDED IT GOES OUT
Nikolay, to open the gas valve, you need a certain water pressure in the water valve. As the flow of water increases, you decrease this pressure and the gas valve closes.
The situation is as follows: when the hot water tap is opened, the flame does not light up for 4 seconds, and then a strong pop. The flame ionisation sensor is not working. Previously, after three seconds there was no flame, the gas supply to the burner stopped. This rarely happens. Neva 4501
Hello Dmitry. The ionization sensor has nothing to do with it. There are several probable reasons: 1. Check batteries (replace if necessary) 2. Check the ignition plug, its position relative to the burner (5mm gap) 3. Poor traction is possible (gases accumulate and therefore cotton occurs) 4. Clean the burner itself from soot 5. Unlikely, but still, the control unit itself requires replacement.
Hello. Column Neva. There is a slight leak in the area of the microswitch. What do you recommend to do?
If you are faced with a breakdown of a water heater, do not panic - our article will help. Malfunctions of the "Neva" gas column can happen for various reasons, but typical ones can be distinguished. We will tell you how to repair Neva models at home.
Important! If your equipment is under warranty, do not disassemble it yourself, otherwise you will lose free service.
How to understand the location of the water heater components? Don't worry, the diagram will help you. It is based on Neva speakers.
Metal casing.
Control window.
Gas flow regulator.
Water regulator.
Digital indication of temperature.
Cold water connection (thread G 1/2).
Hot water outlet.
A branch pipe for connecting to a gas line (cylinder).
A branch pipe for the removal of combustion products is connected to the chimney.
Having understood the design, you can start troubleshooting.
The indicated malfunctions and options for their elimination are suitable for all models produced by "Neva", including: 4510, 5514, 4511, 4513, 4510M, 4513M, 4610, 5611. We will separately consider error codes and breakdowns on the example of some models.
You will need to remove the cover to access the inside of the instrument. How to do it yourself:
Be sure to shut off the water and gas supply.
Pull the adjusters towards you and remove.
Some models have a screw behind the adjuster. Unscrew it.
Disconnect the temperature indicator wiring.
Remove the casing securing bolts.
Pull the trim towards you a little, then up.
You can start repair work.
Reasons for the appearance and ways of troubleshooting.
The burner does not ignite. No spark... In this case, the temperature display does not work when the mixer is opened.
Weak water pressure.If the pressure in the tap is small, you need to wait until the flow is restored. The installed model may be too powerful for your plumbing. Also check the adjustment toggle switch, set to the maximum value. For frequent pressure problems, it is recommended to install a circulation pump.
The batteries are dead. Some users are confused by the scoreboard. If the display is lit, the user thinks the batteries are ok. But lighting a candle requires more current. It is important to choose high quality batteries.
The manufacturer recommends installing LR20 (alkaline) batteries. Therefore, salt cells such as R20, which are sometimes used, will not give stable performance. An alternative to the LR20 is the CR20, but the cost is much higher. To replace, turn the knob in the battery compartment.
Expert Advice: Check food contacts more often. The technique works with water, so the contacts are susceptible to corrosion and chemical deposits.
Defective flow sensor. Inspection and replacement required.
Wear of the rubber membrane. This can be understood by visual inspection. Open the mixer and see how the pusher works. If it does not move, then the membrane is damaged or stretched (marked with a blue arrow in the photo). Red arrows mark places that are susceptible to leaks.
You can remove the water part together with the gas part. The dismantling procedure is marked with letters:
a - after turning off the fuel supply, the supply hose is unscrewed.
b - the cold water nut is loosened.
c - the nut of the water block and the radiator pipe is unscrewed.
d - the wiring of the solenoid valve is disconnected.
d - the microswitch loop is disconnected.
e - the bolts of the flange connection are unscrewed.
Broken electronic board requires a call from a specialist.
Breakdown on the body of the device. A clicking sound is heard, as when a spark is formed, but no ignition occurs. This means that the insulation of the candle is broken. If defects are found during inspection, a serviceable part must be supplied. Also, the cause of the breakdown is a violation of the tight connections of the cable with the control unit. Return the cable to the socket.
The display allows the user to see the fault code. Self-diagnosis of the column gives a digital value in case of a malfunction.
E0 - the boiler shuts down. Fuel does not flow into the system. Check the gas valve; the supply may have been shut off for a short time.
Error E1 - the control board does not receive a signal from the flame sensor. More than a minute passed.
Air in the gas pipeline. This happens when the device is turned on for the first time or when the device is turned off for a long time. Open and close hot water several times until the burner ignites.
The fuel supply valve is not fully open. Unscrew the tap.
Insufficient pressure in the gas line.
The tank has run out of fuel. The cylinder needs to be replaced.
Violation of the wiring between the water unit and the flame sensor, solenoid valve. Examine the loop for damage to the insulation.
The electrode has moved out of place, does not reach the burner. Return the part to its original location.
Soot is present on the electrode and flame sensor. You can clean the parts with a brush.
The contacts between the spark plug and the high-voltage wire are removed.
The nozzles are clogged with soot.
The burner must be removed for cleaning. Disconnect the wiring and unscrew the nipple nut. Unscrew the two manifold bolts, then do the same with the burner mounts. After dismantling, the holes are washed with a brush and soapy water. Reassemble after rinsing and drying.
E3 code - the solenoid valve was triggered earlier than the signal from the flow sensor.
The valve is defective. A new element is being installed.
The electronic unit has broken. Diagnosis is carried out by a specialist.
Error E7 - after 7 attempts to ignite, the equipment still does not light up or goes out.
Open the fuel valve as far as it will go.
The ionization sensor has moved or soot has accumulated on its electrode.It should be in the flame zone, near the burner. Cleaning is done with a brush.
The electrical valves are out of order.
The water or gas block has boiled. Replacement of elements.
Error E8 - the thrust sensor has been triggered. Causes:
The sensor is broken. See if the contacts are tight, change the part.
The chimney is clogged with debris or soot. If you cannot clean the passage with your own hands, contact your utilities.
L0 - not enough fuel is supplied for normal operation. What happened:
Weak water pressure. The line pressure acts on the diaphragm, which opens the valve. Wait for the flow to recover, adjust the toggle switch, or descale the radiator. How to do this is described in the article on cleaning and repairing a gas column heat exchanger.
The temperature at the controller is too low. Increase your metrics.
The pressure in the gas line exceeds the permissible limits. Install the reduction gear.
Such malfunctions are typical for the Neva 3208 and Neva Transit models.
The device works for a while, then turns off... Draft problems that can arise from blockages or improper installation of the hood.
Typical user mistakes:
The ventilation pipe is installed too close to the wall of the chimney, normal draft is not generated.
Another device or hood is connected to one pipe.
There is another window on the level with the ventilation of the column.
The column does not light up or immediately goes out... The temperature sensor is triggered.
Overheating has occurred.
The part is out of order.
The membrane is stretched.
Flame sensor does not work.
Display does not work:
The thermal sensor is out of order. Need a replacement.
Contacts broken.
Display defective.
The equipment is very noisy:
Twist the water regulator. Reduce the head.
The gaskets in the pipe joints protrude out of place. Replace the gasket.
You have learned the structure of the Neva water heater, its typical malfunctions. You can start fixing the problem. We hope our article helped you get the technology back on track.
Since the Neva 4511 series geyser is one of the most common models, the topic of its maintenance and repair is of interest to many users who are accustomed to doing such work with their own hands. Indeed, these open-chamber instantaneous water heaters can often be brought back to life without the need for service personnel. Let's look at what malfunctions occur during the operation of these units, as well as ways to eliminate them.
It is impossible to independently repair a household appliance without knowing how it functions and what it consists of. Unlike old-style water heating devices, this series of gas water heaters is equipped with a controller and electric ignition, which made it possible to remove a constantly burning igniter. The rest of the design remained fairly simple and maintainable. It consists of the following basic elements:
Housing with hinges for wall mounting.
The diffuser is a collection of combustion products with a chimney pipe.
Copper heat exchanger.
Gas burner device.
Water node.
Membrane actuator (so-called frog).
A gas valve with an electromagnet, connected by a common stem to a water unit.
Controller.
Microswitch for power supply to the electronic unit.
Water supply pipes.
Ignition electrode.
Flame detector (ionization).
Additional electrode for ignition of the burner.
The valve is a flow regulator.
Adjustment of the intensity of combustion and heating temperature.
Connection of a draft sensor installed inside the diffuser.
Compartment for batteries (batteries).
The diagram above shows the device of the Neva gas column with numerical designations of parts corresponding to the list.
Automatic switching on and heating is controlled by the water unit together with the controller, and the solenoid valve connected to the draft sensor is responsible for the safe gas supply.The algorithm for the operation of a water heater looks like this:
After opening the hot water tap at the inlet of the "frog", pressure arises, which acts on the rubber membrane of the assembly. It moves the stem that opens the gas valve and closes the microswitch contacts.
When the electrical circuit is closed, battery power is supplied to the controller. He gives 2 commands at the same time: open the solenoid valve for gas passage and create a spark on the ignition electrodes. As a result, the burner ignites.
The flame sensor detects the appearance of fire and transmits a pulse to the electronic unit, which interrupts the sparking. The heater switches to operating mode.
When the valve on the mixer is closed, the pressure in the network disappears and the spring throws the frog diaphragm back, at the same time closing the mechanical gas valve. The limit switch is triggered and the controller loses power, and with it - the electromagnet. The fuel supply is interrupted and the burner is extinguished.
The fundamental point. The solenoid valve is connected in one circuit with the draft sensor (pos. 16 of the diagram). If, for various reasons, the draft in the chimney disappears or weakens, the sensor will heat up and open the circuit, de-energizing the electromagnet. The latter will return to the closed position and cut off the gas supply to the burner.
To exclude possible overheating of the water in the heat exchanger, the manufacturer has implemented a simple technical solution: a temperature sensor connected to the controller is built into the pipeline. If the flow heats up to a critical level (about 90 ° C), then the gas supply will automatically stop and the burner will go out. The structure and principle of operation of the Neva 4511 column is shown more clearly in the video:
In order to fix the malfunction of the Neva gas column with your own hands, you need to diagnose it correctly. Over the years of operation of the water heating apparatus, one part of the parts wears out and requires replacement, the other - periodic maintenance. In this case, a variety of problems arise, characterized by certain symptoms. We propose to divide all emerging problems into groups according to the following criteria:
the burner does not light up when opening the tap of the DHW system;
after working for 5-10 seconds, the unit shuts down;
the flow heater starts up and functions properly, but does not heat the water well;
Advice. Most often, the rubber membrane of the water unit fails in gas water heaters - it stretches, cracks or breaks. This is a consumable part that should always be kept in stock. A sample of the part is shown in the photo.
When the water heater does not react in any way to the inclusion of hot water, you need to perform the simplest action - check the condition of the batteries and the contacts of the battery compartment (they can oxidize). Clean them with sandpaper, install a new set of batteries, and then try firing up again.
An important point. The luminous display of a household appliance does not at all indicate a full charge of the batteries, since it does not consume much energy. If the batteries are "hung up", then the voltage for triggering the electromagnet and sparking may not be enough. According to the specifications published on the official website of the manufacturer, the set of elements is enough for about 250 hours of operation.
Battery compartment location - bottom view of the device
Is the power supply ok? Then continue diagnosing the gas water heater using this algorithm:
Make sure that there is enough pressure in the piping to turn on the device. It is possible that someone accidentally closed the shut-off valve or control valve on the heater itself (on the right).
If there is a strainer on the incoming water supply, check its condition and clean if necessary.
Remove the front panel of the device and open the DHW tap, observing the stem. If it does not move under normal water pressure, the reason lies in the frog's membrane.
The stem has moved, released the switch button, but nothing happens? There is a problem with the electrical circuits. You need to check the microswitch and ring the other wires supplying the controller and solenoid valve.
Advice. When repairing the Neva gas water heater, accompanied by disassembling the unit, just in case, shut off the gas main.
To dismantle the front casing, it is necessary to remove the plastic handles from the control valves and disconnect the display connection connector. At the back, the panel is supported by 2 self-tapping screws located at the bottom of the device. Unscrew them and remove the cover by pulling it towards you and pulling it up.
To check the limit switch, you must disconnect the connector and ring it with a multimeter or lamp tester. When the button is pressed, the circuit must be open. As for the wiring, it rarely fails, unless you catch your eye on a fallen off wire, which is easily removed.
To replace the membrane in the Neva 4511 column, remove and disassemble the water unit together with the gas one, following the instructions:
Close the cold water and gas supply, unscrew both supply pipes with an open-end wrench. Also disconnect the copper pipe leading to the heat exchanger.
Disconnect the controller and microswitch connectors.
The entire water / gas block is fixed with 2 screws to the burner flange. Unscrew them with a Phillips screwdriver and remove the assembly.
Disassemble the frog and replace the membrane, and with it the small O-ring shown in the photo.
Note. The replacement can be done without dismantling the whole block, but it is extremely inconvenient to perform the operation in this position. The described disassembly technology is also suitable for other models of gas water heaters - Neva Lux 4510, 5611 and so on.
How the membrane of an instantaneous water heater changes, see the next video:
When sparking is visible on the spark plug but the burner is idle, check the following points:
whether the spark electrode has moved relative to the nozzle;
whether the traction or overheating sensor that opens the solenoid valve circuit is out of order;
does it pierce a high-voltage wire onto the case;
spark has diminished due to plugged plug or battery discharge.
The electrode should be located directly above the nozzle of one of the burner sections at a distance of no more than 5 mm from it. A violation of the position of the candle is corrected by simple bending. Sometimes it is enough to clean the end of the electrode from soot to increase the spark power.
The operation of the traction and overheating sensors is checked by direct closure of their contacts. Place jumpers on each device in turn, including the water on the faucet. If a flame appears, replace the faulty sensor.
If the flame in the column lights up properly together with the appearance of a water draw, and after 5-10 seconds it goes out, then the reasons may be as follows:
the ionization sensor does not work (does not detect the ignition of the fuel);
there is no draft in the chimney, which is why the corresponding sensor overheats and opens the electrical circuit;
the maximum heating is set at a low water consumption, which is why its temperature quickly reaches 90 ° C and the overheating sensor is triggered.
The last 2 malfunctions do not depend on the water heater and are eliminated by the user on an individual basis. Sometimes the damping effect is created by a diaphragm that is too stretched: at the first moment after water is supplied, it moves the stem, and when the pressure in the pipe is normalized, it releases again.
The flame sensor fails for three reasons:
The electrode is covered with a thick layer of soot and requires cleaning.
The "nose" of the device is bent down from prolonged exposure to temperature and needs to be slightly bent up, as shown in the video.
The device is out of order and needs to be replaced.
The opposite situation also happens: the DHW tap is closed, and the burner continues to work. Here there is a jamming of the stem, which is eliminated by disassembling and cleaning the water-gas block.
There are two reasons for this phenomenon: clogging of the burner nozzles and deposits in the heat exchanger tubes. In the first case, a change in the blue color of the flame to yellow or reddish is noticeable, the gas burner device begins to smoke. To eliminate it, it is advisable to call the gas service master, but if necessary, you can handle it yourself:
Shut off the gas supply.
Dismantle the burner by unscrewing the compression nut on the gas line and 4 screws not shown below.
Purge the assembly in an accessible way to remove dust, and then wash with a mild soapy solution.
Dry the device and re-assemble the column in reverse order.
If the burner operates properly, but the water does not heat up, then the heat exchanger must be flushed. The factory - the manufacturer provides for a simplified dismantling of the element: drain the water from the column, unscrew the two connecting nuts on the pipes (shown in the photo with green arrows) and 2 fastening screws from above. After that, immerse the heat exchanger in a bucket with citric acid solution (100 grams per 1 liter of water) and wait until it corrodes the scale. After thoroughly rinsing and drying, reinstall the element.
Advice. When reassembling the heat exchanger, it is advisable to change the rubber gaskets inside the union nuts.
This is not to say that it is unrealistic or unacceptable to repair the Neva gas water heater yourself. You can really cope with the common malfunctions described above on your own, and without any special tools. It should be remembered that the water heater belongs to gas-powered equipment that requires a careful and thorough approach.
The only characteristic disadvantage of a gas heating device is insufficient power. It is not possible to simultaneously heat water in two autonomous rooms (in the bathroom and in the kitchen), since the design did not include a smooth flame modulation system.
Despite the high quality of the product, the column does not always work properly. Some problems can be fixed on your own, but it is advisable to entrust more complex repairs to a professional. At home, it will not be difficult to cope with minor repairs. For this, some nuances in the operation and repair of the gas appliance are enough.
Consider the most common malfunctions and options for their elimination.
The main reasons for the absence of a flame in a gas appliance may be lack of traction, low water pressure, or dead batteries:
To establish traction in the ventilation system, you will have to completely clean the ducts of the ventilation duct, which is clogged with combustion products, debris and dust. This is easy to do by removing the pipe and providing direct access to the channel. At the end of the work, the joint between the pipe and the wall must be covered with putty to prevent gas leakage.
The batteries can be replaced with one touch. Open the battery compartment and insert new batteries according to the diagram. For long-term use, lithium batteries are better suited. Alkaline analogues have a lower content bone and require frequent replacement. It is noteworthy that a lit display on the device does not always indicate a full charge.
To eliminate the problem of low water pressure, you will need to rinse the filters in the water supply system. A membrane is installed on the water unit, the replacement of which makes it possible to increase the amount of water supplied. The membrane of the water unit is the most vulnerable point of the system. The rubber part may stretch, crack or tear. It is recommended that you have a spare part in case of emergency.
In the event of a malfunction of the thermostat, the column does not recognize the difference between the water flows and does not turn on. To eliminate the malfunction, it is enough to adjust the temperature on the regulator.
Among the reasons for the extinguishing of the fire, a few seconds after ignition, the following should be highlighted:
Broken ionization sensor.In this case, you need to clean the electrode from the soot layer or straighten the sensor nose as shown in the video. Often the part simply fails, so a complete replacement of the element will be required.
Opening of the electrical circuit. As a result of the frequent lack of draft in the chimney, the temperature sensor overheats, and the electrical circuit opens or the membrane stretches. The problem is solved by cleaning the ventilation hole and repairing the electronics (if necessary).
Temperature sensor settings incorrectly set. If a small volume of water is consumed at a set maximum of 90 degrees, the overheating sensor will work and stop the gas supply. To solve the problem, adjust the parameters of the temperature device.
The presence of third-party sounds when the heater is turned on and operating indicates a malfunction. Typically, the problem is a dead battery, a clogged jet, or clogged vents. It is relatively easy to eliminate the causes of breakdown in the first two cases. Changing the batteries and cleaning the jet can save the day. In the case of clogged ventilation shafts, you may have to contact your utilities, as the clog may be out of the reach of cleaning.
Remember that the columns of the Neva 4511 model are designed to heat 11 liters of water per minute. If your needs exceed this indicator, then you should replace the gas appliance with a more powerful one. If the column does not cope with the assigned function for other reasons, then you will have to examine the supply valve and clean out possible clogged places. With a low head or a malfunction of the thermostat, the column will physically not be able to heat the required volume of water. You can try to solve the problem by adjusting the tap. In especially difficult cases, it is better to turn to the services of an employee of a service center or a gas office.
Before commencing repair work, be sure to turn off the gas supply valve. When cleaning the air vent, spread old newspapers and open windows. Periodically check the tightness of the rubber gaskets inside the gas appliance.
Periodically monitor the condition of the heater, replace replacement parts in a timely manner and periodically adjust the temperature sensor settings.
Important! It is better to entrust complex repair work to a professional. Gas equipment requires a careful and thorough approach. An accidental mistake can cost many people their lives.
A gas water heater of the Neva 4510 brand is installed. How can I independently adjust the temperature on this column?
As you can see on the front panel of the Neva-4510 geyser, there are two handles.
If you stand facing the column, then the right handle is the water flow regulator, and the left is the gas handle.
You can adjust the leaving water temperature with one or the second knobs.
If the left knob is set to the “maximum gas supply” mode, the column will accordingly start to consume more gas and the water at the outlet will be hot.
The right handle works in the same way, the more you open it, the more powerful the flow, if you do not change the position of the left (gas) handle, then the water will be colder.
And then everything is individual, the setting is made based on the water pressure in your system.
There are no general recommendations like “put the right handle in this position”.
Look and decide on the spot, if the water pressure in the system is weak, but the column turns on, then put the right knob in the “maximum flow” mode (the toggle switch to the left until it stops), and gradually turn the left knob from the “minimum flow” towards the maximum, as only the outlet water temperature will suit you, and leave it that way.
This gas column actually has a fairly simple adjustment, if you fill your hand, which allows you to catch the required water temperature, not only by diluting it with cold water through a mixer or by limiting its flow into the column, but also through the regulators on the column itself. So, on the front part, to the left of the temperature indicator, there is the adjustment of the gas supply to the burner, and to the right of the indicator is the adjustment of the water supply. They can be used to adjust the final leaving water temperature.
So, possible troubles - if you set the water supply to maximum, and its consumption is low, then the burner will go out. The same will happen if you install a low water supply and a large gas supply. And then you will have to trudge to the column with a soapy head and turn it on.
The operating instructions for equipment such as a Neva 4510 flow-through gas water heater on page 17-18 describe in detail how to adjust it, here is a screen from this instruction:
In this model of the column, standard Chinese automation is installed, on two adjusting knobs - one for the water supply (which regulates the temperature), and the second for the gas supply and flow rate (combustion quality).
The gas column is adjusted with fairly simple movements:
The first is to set the handles (both) to the middle position.
The second is to start the gas water heater.
Third - adjust the combustion of the burners (the fire should burn blue, without overshoot and rise from the burner, the flame is even, the combustion sound is minimal) - twist the gas supply knob in both directions, do not be afraid, find a position where the gas will burn as needed.
Fourth - use the water supply knob to adjust the desired temperature at the outlet of the column - by decreasing the water supply, you will increase the temperature, and by increasing the supply, you will lower it.
After setting, check several times by repeated starts, whether the automation is clearly triggered, whether the column turns on and off.
It happens that you want to save as much as possible on water and gas in order to minimize their consumption, this is done as follows.
On a working column, you need to very smoothly turn the knob for its adjustment in the direction of decreasing the flow of water until the column turns off (it may not turn off to the extreme position, this is good!) won't light up again.
Next, using the gas supply knob (naturally in the direction of decreasing), we adjust the combustion, and, accordingly, the outlet water temperature - we are ready to check everything, several times, if it does not ignite, you need to add a little water and gas, respectively, until it ignites!
Video (click to play).
After such an adjustment, the gas water heater will consume a minimum of gas and, accordingly, heat the water at least!