LG refrigerators have taken a leading position in this segment of technology. The company is considered a global center for innovation. All brands of refrigerators from two-door to sophisticated French and American series are made soundly, stylish design. There are almost no malfunctions of LG refrigerators during the warranty period. Often, repairs are associated with voltage drops in the network - the electronics cannot withstand. When buying a modern refrigerator model, you need to take care of installing it through a voltage stabilizer.
LG refrigerators last a long time. However, technology tends to fail over time. From the first day of operation, you need to take care of the electronic control unit and the compressor, especially the inverter one. Electronic configuration of the program requires attention. Step-by-step instructions are provided in the corresponding section of the documentation for the device.
Some models are noted in reviews as unnecessarily noisy. Part of the reason lies in the build quality at sites scattered around the world. However, the correct leveling, tightening the fasteners with your own hands, and standard ventilation gaps will partially eliminate the noise of the LG refrigerator. Repair is required when extraneous knocking, whistling or strong heating of the compressor is added to the noise.
Breakage is considered if one of the refrigerator chambers has ceased to maintain a given mode. Ice has appeared in the freezer or freezing temperatures are observed in a cold cabinet. There may be several reasons:
failures in the automatic regulation system;
failure of temperature sensors;
faulty relays;
refrigeration circuit problem associated with freon leakage or compressor failure;
malfunction of the solenoid valve in a single-compressor double-chamber apparatus.
Video (click to play).
Malfunction of the No Frost system of the LG refrigerator will let you know by a violation of the temperature regime, icing inside the cooling chamber. The air cooling system for products is complex and balanced. The complex includes an evaporator, from which cold air is blown into the freezer by a fan. Then the gas flows through the air valve to the heating of the positive chamber. Problems may be related to:
the temperature sensor in the evaporator or chambers has failed;
the fan stopped working due to icing or motor failure;
heating element does not work;
air valve not adjusted.
The appearance of ice in the freezer, "fur coats" in the refrigerator indicates a possible malfunction in the condensate drainage circuit.
Refrigerators of this series are characterized by two compartments operating from one compressor. In this regard, a magnetic valve is used that directs the refrigerant flow cyclically and alternately into the chambers. If the solenoid valve for switching modes is "stuck", then the temperature in the freezer will decrease and rise at the top. The unit is not being repaired; valve replacement is required.
Such malfunctions are typical for refrigerators, when on one compressor the mode in the chambers is independent, there are 2 control buttons. As a preventive measure, it is recommended to change the regime, with a deviation from the average values, in case of emergency and not for long.
The apparatus of the Russian assembly, two-chamber, with a "no frost" system, a large freezer at the bottom - has gained popularity in Russian families. Full Know Frost, height 188, bottom freezer, LED backlighting and trouble-free operation for more than ten years - this is how users characterize the device.
The remote control with push-button switching of modes signals about deviations on the Freeze Temp display. After turning off the power, all settings are set to the middle position.The electronic module is located in the upper part under the decorative panel. The built-in self-test mode can be manually activated, testing all systems will take 2 hours.
Typical malfunctions found during diagnostics:
the second light on the left indicates an open or short circuit in the freezer sensor;
the fourth light on the left is on - defrost sensor malfunction;
all the lights are on - No Frost is not working.
If ice is found under the bottom shelf of the freezer, the condensate drain system is clogged. To clean it, you will need to remove the decorative lining and find the drain hole. You can defrost the tube yourself. For all manipulations, the refrigerator must be de-energized.
If Know Frost works, the sensors are working properly - problems in the cooling circuit. Only a master can check the amount of freon, whether there is a passage in the capillary tube, the compressor's performance.
Model in silver color with linear inverter compressor, height 200 cm. Multi-stream cooling system and Know Frost are used. Electronic control with self-diagnostics.
Analysis of equipment failures before the end of the warranty period shows that the model is reliable and rarely gets repaired. The main causes of breakdowns:
the starting relay does not work;
the electronic control unit burned out;
the temperature sensor has failed;
the sealing rubber is worn out.
Most often, problems arise in switching the operating modes of two circuits or in the incorrect operation of the Nou Frost system. The inverter motor has a 10-year manufacturer's warranty. Continuous operation of the sealed circuit allows you to save pipe connections from starting shocks and vibrations, preventing freon leakage.
Model with a mirrored front surface, two-compartment, with a bottom freezer. Compressor one. Electronic control. Defrosting of the upper chamber is automatic, of the lower one - manual.
Refrigerators malfunctions are related to their design:
does not keep the freezer or refrigerator mode;
an ice coat is growing in the refrigerating chamber;
water accumulates under the drawers of the refrigerator;
puddles are on the floor under the refrigerator.
If the mode in the chambers is violated, one of the temperature sensors may have failed. Another reason is often a malfunction of the bypass solenoid valve. The temperature in the refrigerator can be high due to a loose door closing, worn out sealing rubber. Sometimes the contact is broken, the light in the cell is on even when the door is closed.
If you have done everything that the instructions prescribe, it remains to call the wizard. He will establish the reasons. In addition to the listed malfunctions, there may be:
Freon leak from the damaged circuit;
malfunction of the compressor or engine start relay;
blockage of the compressor tube.
The signs of problems are similar, and only a specialist can find and fix the breakdown.
Two-compartment refrigerator, beige with a quiet inverter compressor and a Nou Frost full defrost system. The freezer compartment is located at the bottom. Electronic control, push-button display. No temperature display. The backlight is produced by an incandescent lamp.
Malfunctions of the LG refrigerator of this model and their elimination are not original. But using an inverter compressor removes problems with the refrigerant circuit. Isobutane used, capillary clogging unlikely. Radiator leaks are rare. Therefore, the circuit is reliable.
The Nou Frost system, the serviceability of temperature sensors and relays, and the removal of condensate can become problematic. A specialist can determine the exact reason why it is warm in the positive chamber and ice freezes in the freezer. It is the user's task to comply with the operating conditions.
We offer you to look at an overview of the LG refrigerator model.
I'll start with general concepts, or rather, I'll tell you why in the refrigerator with the No Frost system, the cold disappears in the refrigerator compartment.If you have such a misfortune, then first of all pay attention to the freezer, or rather, how it freezes, if the food is not thawed, then most likely the problem is in the malfunctioning of the evaporator defrosting system. In order to make sure of this, you need to remove the front panel and get to the freezer itself, if I was right, then on the freezer evaporator, you will see a pile of ice, this method is suitable for those who urgently need to start the refrigerator, but for those who are not limited by time , I can offer one more diagnostic method. The second method is much easier, but this will take at least 3 days, in general, you need to do the following procedure
Feel the sides of the case → if they are hot, then it is clearly not a matter of freon leakage, and in this case, you can proceed to the next step
Disconnect the refrigerator from the mains for three days → such a long period is needed for the ice to melt on the evaporator. Be sure to open the doors to both cells
Turn on the refrigerator → time should be noted, after 2/3 hours the engine should shut off. It is advisable to put outdoor thermometers in both chambers, which show sub-zero temperatures.
It is very important that the first mode, that is, before it is turned off, the refrigerator works without food, then you can slowly load them. If in both chambers, you see a normal temperature, then do not rush to rejoice, in most cases the problem repeats. In this way, you can start the refrigerator, in normal operation, for 2-3 weeks, I think this is enough for the master to arrive or you can buy the necessary parts to replace them. Now you can start diagnosing faults, that is, we will look for the causes and eliminate the consequence, but first I recommend watching the video in which I showed how to get to the freezer evaporator and, in general, about general faults Al G. No Frost
Watch the video on how to get to the freezer evaporator in the LG No Frost refrigerator, as well as about the general breakdowns of this unit