In detail: vestfrost refrigerator do-it-yourself repair from a real master for the site my.housecope.com.
Before cleaning the inside of the refrigerator, turn it off by pressing the on / off button. Household appliances are best washed with warm water (maximum 85 ° C) and a little mild detergent. Never use scratching or abrasive cleaners. Use a soft cloth. Rinse with clean water and wipe dry.
It is very important that no water gets inside the control panel.
The drain for defrost water, which receives condensation from the refrigerator, is located on the back wall of the inside of the refrigerator. He must always be clean. Place a few drops of disinfectant a couple of times a year into the drainage system and clean the drainage tubes with a brush or similar.
Never use sharp piercing or cutting objects for this.
The sealing strip around the door must be cleaned regularly to avoid discoloration and prolong its life. Use clean water. After flushing the sealing strip, check to see if it seals properly. Dust that accumulates in the compressor compartment and on the compressor is best removed with a vacuum cleaner.
The protective plate can be removed for cleaning under the appliance. Doors made of stainless steel and aluminum are best cleaned with special products and a soft cloth. Various products for this purpose are available in most household appliances stores.
If the appliance will not be used for an extended period of time, turn it off, remove all food from it, wash the interior surfaces and all accessories, and leave the door slightly open to allow air circulation and prevent unpleasant odors.
Video (click to play). |
Turn off household appliances by pressing the power button and unplug the power plug. Use a flat screwdriver to remove the cover from the lamp. Install a new 11W PLC bulb. Replace the cover, insert the plug into the socket and turn on the appliance by pressing the on / off button.
During use, various problems arise. If a malfunction is detected, a flashing letter will light up on the indicator display. E and number. The control lamp alternately flashes red, green and yellow, and a sound signal is also switched on. If this happens, qualified Westfrost refrigerator repairs are available by calling the center at 8 (495) 117-93-25. The built-in emergency program will try to maintain an acceptable temperature until the error is corrected.
I have a Vestfrost BKF 355 two-compartment two-compressor refrigerator. The freezer is working. When the refrigerator compartment is turned on, it works for a while, then it turns off and does not turn on again. Maybe something with a thermal sensor?
You do not have any sensors in your unit, only two compressors and two thermostats. If the refrigerator does not work, then the malfunctions may be as follows. The cold compressor is out of order. cameras. Thermostat malfunction. Freon leak from the cold system. branches.
Freezer Vestfrost vd 285 fna w (electronically controlled, one compressor and Know Frost, LED display on the door). Frost has formed at the top, today it was defrosting forcibly all day. After I turned it on, the SL indicator came on and the SUPER FREEZE light came on. After 6 hours, the LF error has been flashing for an hour. The engine hums. Has broken?
An LF error means that your freezer cabinet is too hot.The reasons for the malfunction may be the following: Freon has come out of the system. Freezer compressor damaged. Evaporator defrost sensor failure. Defrost heater malfunction. Failure of the control module.
I have a question about the Westfrost SW 350 refrigerator. It works as if the wind blows in the chimney of the oven in winter and the meat and greens in it spoil already on the second day. Tell me, what's wrong with him?
These models are usually two-compressor. Therefore, the reasons for the malfunction are as follows. If greens and meat go bad in the cold. chamber, the drain hole may be clogged. It is located on the back wall at the bottom. Oxygen does not circulate and food deteriorates. This problem can be rectified by yourself by cleaning the hole. One of the compressors is broken. Freon leak in the cooling system. To check this problem, simply defrost the equipment for a day. If the unit then does not work at all, then this is a leak. If the drain hole is not clogged, we recommend calling a specialist for diagnostics and subsequent repair.
The Vestfrost BKF 404 refrigerator, refrigerator and freezer chambers are working normally, but it has become noisier to work, the sound comes from the top of the back of the hall. branches. Thawed it, left it for 24 hours, after turning on the sound is the same. I didn’t timed the time, but it seems that the time intervals between the work and the rest of the compressor became less. Disregard or need some kind of repair?
You don't have to worry. Of course, the motors will run louder over time. they wear out slowly. Do not worry about this.
I have a bkf 420 two-compartment refrigerator with electromechanical control (thermostats). The problem is that in the hall. the compartment, everything freezes. I put the temperature regulator at 0 degrees, the x-k turns off, I conclude that it's not about it. What could it be?
The most likely reason that the unit freezes is a malfunction of the cold thermostat. branches.
The Vestfrost VD 285 fna w freezer periodically starts beeping and the temperature display flashes, when pulled out and immediately turned on, it stops beeping, and the same temperature turns on. And if you do not turn it off, then over time it also stops beeping, but the temperature does not turn on, the board flashes.
Look at the display to see if there is a letter warning (Sr, LF, LP)? Most likely an LF error, which means that the temperature in the chamber is higher than the permissible one. The reasons may be as follows: often the doors open, the doors are not closed tightly, warm food in the chamber, high temperature in the room, or a breakdown.
Refrigerator Vestfrost SW 350 M, freezer does not work. Tell me the reasons for this problem.
If the freezer does not work, then the problems may be as follows. Freezer compressor burned out. Freezer thermostat defective. Blockage in the cold capillary tube. branches.
I have a two-compartment refrigerator Westfrost BKF 355 with 2 compressors and electromechanical control. We have been operating since 2007. The freezer is working. Hall. the department now works like this: I turn it off and on - it freezes until the desired temperature is reached and turns off. After turning it off, it no longer turns on until I manually turn it off and on again. camera. That is, it is warm almost all day long.
If cold. the compartment does not turn on when the temperature is reached, then the thermostat is broken, maybe the thermostat needs to be replaced with a new one.
Refrigerator Vestfrost bkf 404. In the cold. the compartment is warm, the motor does not work. If you “reboot” (turn off the mains, turn off the compressor, turn on the mains, turn on the compressor), then the motor is turned on for a long (day) time, then the history repeats. What could be the problem?
If, after a day of operation, the compressor no longer turns on, then 2 malfunctions are possible: Failure of the cold thermostat. branches. Freon leak in the system.
We use the Westfrost freezer vd 285 fnas.Should the motor turn off after reaching a certain temperature or the motor should be constantly in operation. Should 2 buttons light up at once (Power and Eco) if it is in economy mode?
The motor must shut off. so everywhere. The indicators should also be on.
In operation, a two-compartment refrigerator BKF 355 with two motor-compressors and mechanical control. The lower door seal is torn. If you can help me, I will gladly purchase this hard-to-find part.
The sealing rubber profile for your model is MA. Dimensions for cold. compartments - 104 x 57.5, for the freezer - 57.7 x 57.5. You will not be able to purchase a "factory" seal, you need to make it.
Help me please. We bought a Vestfrost VD 285 fnas freezer a month ago. It freezes perfectly, but beeps 3-4 times a day and turns off (the display goes out). What to do about it?
Perhaps because of the heat, such problems arise.
We have a problem with a Vestfrost SW 312 M two-compartment refrigerator with electromechanical control. A fur coat is freezing in the freezer. There is a snowball in the boxes themselves. The thermostat was changed a year ago. Everything worked well, but not for long. What could be the problem, tell me, please.
Most likely the reason that ice freezes in the freezer is the following - the freezer thermostat is out of order. Blockage in the capillary system of the chemistry.
Errors in Westfrost refrigerators
SR error - She says that there is some problem. That is, it is possible that some component part is out of order, or something went wrong in the cooling process.
LF error - This error indicates that the temperature in the freezer is not low enough, roughly speaking, it is too warm in this chamber. Such letters are most often seen on the display after prolonged power outages. Do not forget that if the food is thawed in the freezer, then they must not be re-frozen, in order to avoid loss of their quality or even damage to the food. Experts recommend setting a lower temperature mark to solve the problem with this code and wait until the freezer reaches the temperature you need.
LC error code - It means in the hall. the camera is too warm. It is worth knowing that the ideal temperature for this compartment is plus 4 degrees Celsius. When you see a notification on the screen that the desired temperature regime has gained strength, then the risk of food spoilage has passed - you can be sure about them. Just set the control panel to a lower temperature and wait until it reaches the value you selected. It is best not to open the unit for a while, then, most likely, the notification will disappear from the display.
HC error means that it is too cold in the refrigerator compartment and the food freezes over. First of all, you need to check whether the cooling mode of food is adjusted properly, and otherwise, simply set the required temperature using the buttons on the control panel, according to the instructions for your model.
LOPO error - this code indicates that the voltage in the mains is rather low. Remember that if a power surge drops it below 170V, then the unit will not cool the food. As a rule, experts do not regard this as a breakdown, and this function was created only in order to prevent the failure of the motor-compressor. As soon as the voltage is normalized, the code should disappear from the display. If you see these letters on the screen, it is better to secure the equipment by unplugging it completely from the mains, pulling the power cord out of the socket before the voltage drop stops.
LF / LC error - It says that the temperature is not low enough in both chambers. As a rule, you can see such a notification when you turn on the device for the very first time, as well as after long interruptions in its operation.You only need to worry and think about repairs if the notification appears suddenly, while the compressor is running.
Malfunctions and repairs
Breakdowns and malfunctions may be as follows: the cold thermostat (thermostat) has broken. compartments at a single-compressor device. Signs of such a breakdown are the failure of the motor to operate in any position of the thermostat lever, when the cameras do not work, the light does not light up inside, or a red light is on, notifying of the emergency indication. The cause of the problem may be an open circuit between the thermostat and the motor, due to which it does not start.
Another sign of a thermostat breakdown in models of this technique is poor cooling, a positive temperature of both chambers. The motor rarely starts and turns off quickly due to a faulty temperature sensor, which incorrectly informs about reaching the set temperature values. A red light may be on on the case to indicate an increase in temperature in the chambers. Electronic devices may display an error code. Also, a breakdown of the thermostat in a single-compressor Westfrost refrigerator is manifested by freezing. The operation of the motor-compressor is observed with short and rare interruptions. That is, the motor does not receive a command from the thermostat to stop cooling.
Breakdown of the cold thermostat. compartments in a twin compressor unit - Symptoms of a breakdown are poor cooling in the cold room. compartment, the rare inclusion of the motor and the display of error messages on the screen. A broken thermostat incorrectly signals a normal cold room temperature. compartment, does not send a command to the motor to start cooling. Freezing possible in the refrigerator compartment, but one compressor runs continuously with slight variations. As a result of a breakdown of the thermostat, incorrect information about insufficiently low temperature is received. Because of this, the motor runs more frequently (to compensate for higher temperatures).
Failure of the thermostat in the freezer compartment of the two-compressor unit - The consequence of the malfunction is an inoperative high temperature freezer when the motor corresponding to it does not start. In electromechanical modifications, in case of such a violation, the emergency indicator (red light) may light up, and electronic models reflect an error on the screen and emit a squeak. The cause of a breakdown may be an open circuit in the motor and thermostat in the freezer.
If the thermostat is broken, poor freezing in the freezer may occur, with an excess of temperature. Moreover, one motor is rarely
working. In such cases, it is required to replace the thermostat with a serviceable part. Another symptom of a breakdown of the thermostat is freezing, the appearance of a "fur coat" on the walls. The motor runs continuously, with short interruptions, since the thermostat considers that the temperature in the freezer is too high.
Malfunction of the motor-compressor. It should be noted that there are several manifestations of this breakdown in Westfrost refrigerators. Motor does not start - On a single compressor unit, the two chambers will not be cooled, but the internal light is on. Typically, electronic models will reflect an error, and in electromechanical views, a red light will turn on. The motor is constantly running - The motor may run continuously, but the temperature inside does not drop, the light remains on. A red indicator on the case lights up.
The motor turns on for a few seconds - The motor turns on and off for a few seconds, before starting, a click of the triggered starting relay is heard. The chambers of a single-compressor unit do not work, and in a 2-compressor unit one compartment is turned off. Broken compressor heats up. In electronic models, a breakdown is manifested by a squeak, and in electromechanical models, by turning on a red indicator. Usually, this closes the winding in the motor.
Freon leakage - At the same time, in a 1-compressor apparatus, an increased temperature is observed in two chambers, and in a 2-compressor apparatus, more often in a freezer. In the first stages, the motor continues to work, trying to compensate for the lack of cooling. With the gradual evaporation of freon, an increase in temperature is observed in the compartments, the unit begins to melt and flow. When the refrigerant has completely drained out, the engine will no longer start. In electronic units, when a leak occurs, an error is indicated on the screen and a sound appears, and in electromechanical models, a red lamp is on. Freon often leaks out in the steel circuit as a result of corrosion. This will show signs of rust around the freezer. Another reason for refrigerant leaks is a "crying" evaporator made of aluminum and damaged by corrosion (in this case, a bulge appears on the back of the unit).
Flaws in the refrigerator installation - uneven or non-horizontal floor, etc.
What can be done:
Adjust the vertical position of your refrigerator by rotating the adjustable feet.
What can be done:
This breakdown can only be fixed by an experienced refrigerator repairman. By contacting us, you will soon be able to use your refrigerator without any problems.
The piping is touching the wall or other structural parts of the refrigerator.
What can be done:
You can try to fix this problem yourself, but if necessary, our specialists will do it for you.
Perhaps it's just the food pressed against the evaporator located on the back wall. They can interfere with the normal outflow of moisture into the drainage system and water flows to the bottom of the cabinet or falls into the drawers below.
What can be done:
It is enough just to move everything that touches it from the back wall.
Refrigerator drainage clogged.
Troubleshooting methods:
What can be done:
You can try flushing the drainage system with clean water using a pharmacy-bought enema pear.
Capillary line clogged
What can be done:
This breakdown cannot be eliminated on its own, moreover, not even every master can eliminate it - the work is quite responsible and difficult. But our service center employs specialists who have experience in solving such a problem.
Leakage of refrigerant - freon
What can be done:
Only an experienced and qualified specialist with a set of professional tools and devices can eliminate this kind of breakdown. Therefore, we can recommend contacting our center.
What can be done:
This is one of the relatively common problems, therefore, in terms of eliminating it, our masters have gained good experience. Contact our service center and your Vestfrost refrigerator will restore its original high thermal insulation, which allows you not to waste energy.
Sometimes this is caused by a short circuit in the winding of the motor-compressor or a malfunction in the electronic module of the Vestfrost refrigerator. But to clarify the malfunction, professional diagnostics are required, and then - troubleshooting. All this can be done for you by specialists invited from our service center.
A similar problem can be caused by a malfunction of the starting relay. A confident user with tools can try to repair the damage himself. But if you want a guaranteed reliable operation of the refrigerator in the future, contact our center for professional help and your refrigerator will be repaired with high quality and using original spare parts.
Lack of voltage in the network
What can be done:
Consult an electrician to repair any damage to the outlet or wiring.
Damage to the power cord
What can be done:
Eliminating such a breakdown is also a job for a specialist.Contact us and the problem will be solved as soon as possible, quickly and, most importantly, reliably.
Malfunction of the automatic defrosting system "No Frost".
What can be done:
This electronic repair system requires knowledge of the repair of sophisticated modern household appliances. The specialists working in our center have the necessary qualifications, specialize in the repair of the most relevant brands of refrigerators, which include the Vestfrost brand, and have a stock of original components necessary for a full repair and long subsequent operation.
Electronic module malfunction - control board
What can be done:
Failures of the control board can most often be repaired, which will be done for you by our master, arriving at the time specified in the order.
Damage to the winding of the motor-compressor
What can be done:
A motor-compressor with a broken winding must be replaced. Our specialist will arrive at a convenient time for the customer and replace the motor-compressor.
Breakdown of the temperature regulator - thermostat.
What can be done:
The breakdown of the thermostat is eliminated by replacing the damaged one with a new one, always of original production. For this, the services of our service center are best suited - only reliable qualified craftsmen, only high-quality original parts and assemblies.
Breakdown of the starting relay.
What can be done:
This problem can be eliminated only by replacing the damaged assembly. Since such work requires not only an original spare part, but also skills in working with modern household appliances with electronic equipment, we recommend that you contact a professional service center. Our staff will do this job for you by supplying a new original start-up relay.
This usually means a breakdown of the motor-compressor, which can be caused by:
- Failure of the automatic defrosting system "No Frost". It can be removed only by a specialist with a set of appropriate tools.
- Damaged winding of the motor-compressor. Remedy - replacement of the entire motor-compressor unit.
- Defective thermostat - the breakdown is also eliminated only by replacement.
- Electronic control board defective. In this case, it is possible to repair this module, but the decision about this is taken by the diagnostic specialist.
- Breakdown of the start-up relay - is eliminated by replacement.
Any of the situations described requires the intervention of the wizard. And we will be happy to provide you with the services of such specialists at an adequate price and with a guarantee.
To begin with, it is recommended to check whether the refrigerator door is tight enough to press the tab that regulates the on / off of the lamp. Then clarify whether the bellows tubes have disconnected from the evaporator, and, if necessary, restore contact. If the cause is a thick layer of frost, it may be sufficient to simply defrost the refrigerator. The reason may also be in the accidentally activated deep freeze mode, in which case you need to return the switch to the storage mode.
Please note: It is recommended to protect the refrigerator from heat sources and direct sunlight and try to keep the outside temperature below 30 ° C.
In the event that the temperature regulator has broken down, it will have to be replaced. Our experts will fix such a breakdown in your Vestfrost refrigerator using an original spare part.
The first and simplest reason is the accidentally turned on deep freeze mode provided in Vestfrost refrigerators and is suitable only for certain types of food. In this case, it will be enough just to select the normal storage mode. But if the situation is caused by a breakdown of the thermostat, then you cannot do without professional diagnostics and replacement of the failed unit.The employees of our service center have significant experience in this area and will eliminate the breakdown efficiently and quickly.
Another reason is the thermostat accidentally set to too high a value. Here everything is also simple - you need to choose the right value and set the thermostat to it. If the bellows is not secured well enough, you can fix the bellows tube to the metal plate of the evaporator. Well, if the breakdown turned out to be caused by a deterioration in the operation of the motor-compressor or a clogged capillary pipeline, then again you cannot do without the help of a specialist specializing in the repair of refrigerators, with which our service center will help you. We provide our services throughout Moscow and the Moscow region.
Malfunction of the automatic defrosting system "No Frost".
What to do:
To eliminate this kind of breakdown, qualifications are needed precisely in the field of repairing modern refrigerators. It is most reasonable to immediately contact our service center, where experienced and, most importantly, well-trained craftsmen have both the necessary knowledge and the necessary tools, fixtures, spare parts and assemblies used by the manufacturers of these household appliances. Thanks to this, the refurbished refrigerator will not be inferior to the new one in terms of the quality of work.
Leakage in the freon supply system.
What to do:
To begin with, it is worthwhile to independently inspect the freezer and the evaporator plate on the rear wall for possible defects and mechanical damage visible to the eye. Having found such damage, the refrigerator should be turned off, the damaged area should be sealed if possible, at least with plasticine to avoid moisture ingress.
But it should be understood that the gas can escape even from microscopic cracks. In any case, an experienced specialist will find the defect and find the right solution.
The refrigerator motor-compressor has lost its performance.
What to do:
Only an experienced craftsman with professional tools can confidently diagnose and eliminate this breakdown. We will send you just such a specialist and give a guarantee on the result of his activity.
The Westfrost company was founded in 1963 and is currently the largest manufacturer of household equipment in Scandinavia, which exported refrigerators of this brand are distinguished by their unique design, ease of use, but under the influence of external factors and from long-term use, they can break down, requiring repair and restoration work.For those people who once purchased a Westfrost refrigerator, malfunctions may be as follows:
Signs of such a breakdown are the failure of the motor to operate in any position of the thermostat lever, when the cameras do not work, the light does not light up inside, or a red light is on, notifying of the emergency indication. The cause of the problem may be an open circuit between the thermostat and the motor, due to which it does not start.
Another sign of a breakdown of the thermostat in Westfrost refrigerators is poor cooling, a positive temperature in both chambers. The motor rarely starts and turns off quickly due to a faulty temperature sensor, which incorrectly informs about reaching the set temperature values. A red light may be on on the case to indicate an increase in temperature in the chambers. Electronic devices may display an error code.
Also, a breakdown of the thermostat in a single-compressor Vestfrost refrigerator is manifested by freezing. The operation of the motor-compressor is observed with short and rare interruptions. That is, the motor does not receive a command from the thermostat to stop cooling.
Symptoms of a breakdown are poor cooling in the refrigerator compartment, occasional start-up of the motor and display of error messages on the screen.A broken thermostat incorrectly notifies about the normal temperature in the refrigerator compartment, does not send a command to the motor to start cooling.
Freezing possible in the refrigerator compartment, but one compressor runs continuously with slight variations. As a result of a breakdown of the thermostat, incorrect information is received about the insufficiently low temperature in the refrigerator compartment. Because of this, the motor runs more frequently (to compensate for higher temperatures).
The consequence of a malfunction is an inoperative high temperature freezer when the corresponding motor does not start. In electromechanical modifications of refrigerators, in case of such a violation, the emergency indicator (red light) may light up, and electronic refrigerators reflect an error on the screen and emit a squeak. The cause of a breakdown may be an open circuit in the motor and thermostat in the freezer compartment.
If the thermostat is broken, poor freezing in the freezer may occur, with an excess of temperature. At the same time, one motor rarely works. In such cases, it is required to replace the thermostat with a serviceable part. In this situation, it is important to take into account that the service performing the repair of used equipment. refrigerator, supplied you with original components, or their certified counterparts.
Another symptom of a breakdown of the thermostat is freezing, the appearance of a "fur coat" on the walls. The motor runs continuously, with short interruptions, since the thermostat considers that the temperature in the freezer is too high.
Several manifestations of such a breakdown in Vestfrost refrigerators should be noted:
On a single compressor unit, the two chambers will not be cooled, but the interior light is on. Typically, electronic models show an error, and in electromechanical views, a red light turns on;
Continuous operation of the motor is possible, but the temperature inside does not drop, the light remains on. A red indicator on the case lights up;
For a few seconds, the motor turns on and off, before starting, a click of the triggered start relay is heard. The chambers of a single-compressor unit do not work, and in a 2-compressor unit one compartment is turned off. Broken compressor heats up. In electronic models, a breakdown is manifested by a squeak, and in electromechanical models, by turning on a red indicator. Usually, this closes the winding in the motor.
At the same time, in a single-compressor Westfrost refrigerator, an increased temperature is observed in two chambers, and in a two-compressor refrigerator, more often in a freezer. In the first stages, the motor continues to work, trying to compensate for the lack of cooling. With the gradual evaporation of freon, an increase in temperature is observed in the compartments, the refrigerator begins to melt and flow. When the refrigerant has completely drained out, the engine will no longer start. In electronic units, when a leak occurs, an error is indicated on the screen and a sound appears, and in electromechanical models, a red lamp is on. Freon often leaks out in the steel circuit as a result of corrosion. This will show signs of rust around the freezer. Another reason for refrigerant leaks is a "crying" evaporator made of aluminum and damaged by corrosion (in this case, a bulge appears on the back of the unit). The master must restore the vestfrost refrigerator, the malfunctions of which are eliminated in a short time with a quality guarantee.
Just call our master. He will advise you, answer all your questions, tell you what kind of breakdown can be and how much it will cost to repair it!
One of the world leaders in the production of freezing equipment, the Danish company Vestfrost has been producing reliable and high-quality refrigerators for more than half a century. A distinctive feature of modern refrigerators of this brand is the presence of two compressors. The main priority of the company is caring for the environment.In this regard, the company has invented and implemented an environmentally friendly technology that minimizes the use of freons. A wide range of refrigerators is available in various color combinations with unusual design solutions.
As statistics show refrigerator repair Westfrost have to be performed on products that have been used for more than ten years. This speaks perfectly to the highest build quality and constructively thought out details. There are several types of repairs for refrigerators of this brand. The first of them is minor repairs carried out in the early stages of operation, which can be equated to the elimination of minor problems manifested in the violation of the door adjustments of the refrigerator compartment and the increased temperature inside the refrigerator. Elementary cleaning of the drain channels will eliminate unpleasant odors in the interior space. Increased vibration during compressor operation may be caused by improper leveling of the refrigerator.
All error codes can be found in the technical description of the product or from consultants of service centers, as well as in a special section of our website. It should be remembered that observance of the operating conditions will help to prevent or completely avoid complex, and maybe overhaul repairs of your refrigerator.
For any code and malfunction, experience in equipment repair is required. Therefore, do not try to repair the refrigerator if you do not have certain knowledge and experience. Self repair, like self-medication, it can lead to irreparable consequences.
The range of refrigerators of the Scandinavian brand "Vestfrost" has a fairly wide variety in terms of design, colors, equipment and capacity. Each buyer will be able to choose for himself the model that best suits his preferences and needs. In addition, the units of this company meet all quality and safety standards. However, technology remains technology and its components and systems, in one way or another, are subject to natural wear and tear, failures or breakdowns of a different nature.
We offer our customers a wide range of services and quality repair of Westfrost refrigerators at the most pleasant prices. Our specialists will be able to repair even the most outdated household appliance. We can easily select the necessary part or unit for replacement. The assortment includes consumables and spare parts, both of original origin and analogs that will perfectly suit your refrigerator.
Cooling does not work. This occurs for some reason, for example, the thermostat has failed, which requires its replacement. The motor-compressor has stopped working due to a short-circuited winding or heavy loads. A component called a starter relay has failed and ensures that the compressor is switched on and off on time.
There is water in the refrigerator... This malfunction can be observed due to a loose fit of the door seal to the refrigerator body. Also, wear or tear of the sealing gum is possible, which allows warm air to enter one or both chambers. Thermostat malfunction, damage to the evaporator, air sensor or heating element of the evaporator. In refrigerators with a No Frost system, there may be a blockage in the air pipes or a malfunction of the dampers.
Leakage of current to metal parts of the device. This most often occurs due to an open or faulty electrical wiring and a violation of the integrity of the electrical circuit. Professional inspection and repair of Vestfrost refrigerators is required.
Why do clients come to us?
- Our manager will advise you by calling 8 (495) 162-06-44 and 8 (926) 743-21-17
- Free diagnostics * and visit of a specialist to the client's address; * Please note that diagnostics are provided free of charge in case of subsequent repair of the Vestfrost refrigerator. In case of refusal to repair for any reason, the cost of diagnostics is paid in full, according to the price list.
- Flexible work schedule, which allows the customer to choose a more convenient time for diagnostics and repair;
- Exceptional professionalism of all our craftsmen and high efficiency of execution;
- Warranty for all spare parts and components up to 12 months;
- We give good discounts to the privileged category of citizens, as well as to regular customers !;
To repair of Westfrost 350 refrigerators, repair of Westfrost 355 refrigerators or repair of Westfrost Ford refrigerators was produced with high quality, quickly and without the need for repeated maintenance, you need to rely only on proven service workshops that have proven themselves well.
Our company has a large number of positive reviews, recommendations of clients who applied to our service and a long work experience, which in itself is an indicator of our competence and professionalism. If you want to receive quality service, prompt response and a pleasant cost of repairing breakdowns, call our company by phones: 8 (495) 162-06-44 and 8 (926) 743-21-17, or order a call back on our website. Services are provided 24/7, seven days a week, holidays and breaks. The client can appoint the most convenient time for a specialist to leave, and at the appointed time our master will be at your address.
Very often household appliances, which are subjected to daily intensive use, fail. A private foreman for the repair of refrigerators can assign a fairly round amount, but fortunately, all the work can be done with your own hands.
Before starting repair work, you need to find out the place and reason for the strip. The simplest, most accessible, but at the same time, and dangerous indicator is water, which can flow under the freezer or flow out directly from the refrigerator. If a Soviet refrigerator is leaking, then there may be two reasons:
- Drainage is clogged;
- The container in which the condensate collects is overfilled;
- The drain pipe is leaking.
It will not be difficult to eliminate such breakdowns, but we will tell you more about this below. If the water does not flow, and the Electrolux, Nord, Ariston and others simply stopped working, then you need to carry out a comprehensive diagnosis.
Urgent repairs of even the most complex refrigerator can be done at home with your own hands. Let's take a look at step-by-step instructions on how to troubleshoot the most common problems in refrigeration systems.
Video: how to repair a refrigerator with your own hands
Refrigerator repair prices depend on the type of problem and the specific company. Sometimes different consumables and urgent call of specialists are also separately taken into account. Consider the price list for replacing the compressor motor:
Our service center received a request from a client who had a problem with the Westfrost refrigerator. The essence of the appeal was that the Westfrost twin-engine refrigerator did not turn on. Suspicion fell on a thermostat malfunction.
A specialist from "Golden Hands" went to the client's home to diagnose the malfunction, after which it was confirmed that the thermostat was not working properly. Failure of this element leads to the fact that the refrigerator motor-compressor does not start. Accordingly, due to a breakdown, the refrigerator ceases to function, since the thermostat is the main spare part responsible for regulating the temperature in the refrigerator. For further correct operation of the unit, it must be replaced with a new one.
To remove the old thermostat, our foreman had to dismantle the top panel of the unit, behind which was the faulty part.
To install a new thermostat in this model Westfrost refrigerator, you need to unscrew the back wall, behind which the evaporator is located, in order to bring the thermocouple to the evaporator.
Video (click to play). |
Having installed all the parts in their proper places, the specialist assembles the refrigerator in the reverse order and turns it on. After observing for a while and making sure that the refrigerator began to pick up cold again, the foreman issued a receipt with the warranty for work indicated in it and a new spare part that was installed.