In detail: pump mq 3 45 grundfos DIY repair from a real master for the site my.housecope.com.
Equipment Grundfos (Grundfos) due to their reliability, performance and ease of use are widely used in all industries.
They are used in the field of housing and communal services in the construction of centralized heating, water supply, sewage disposal, servicing agricultural and forestry enterprises, as well as in equipping industrial complexes.
Timely maintenance of a pump or pumping station for any purpose is a guarantee of its correct operation and the durability of the system as a whole. Repairing pumps in a specialized service center, for example, in Sergiev Posad, is initially an expensive pleasure. However, if you are familiar with the device of the unit and understand the principles of its operation, it is quite possible to eliminate the malfunctions on your own.
to the menu ↑
The Grundfos range is represented by all the main categories of pumping equipment:
- downhole;
- sewer;
- centrifugal;
- circulating;
- multi-stage self-priming units.
Range of pumping equipment Grundfos
Borehole pumps are used in the water supply system and in the arrangement of wells with artesian water, for filling tanks and other water distribution systems. As a rule, these are downhole installations operating in continuous or short-term mode, regulated by a pressure switch and a hydraulic tank. The product package includes three main elements - the engine, the built-in filter and the upper or lower water intake system. Products are represented by the series of equipment SP, SQ and SQE.
Video (click to play). |
Consider the device of Sololift sewage pumps, using the example of a typical Sololift 2 WC 3 unit. The unit consists of a tank equipped with inlet / outlet openings, into which waste water enters. After the pre-cleaning provided by the filtration system and upon reaching a certain level, which is monitored by the Grundfos level sensor, the pump switches on automatically. Thus, the process of pumping out liquid into a centralized line, septic tank or other disposal tank is started. The unit is also equipped with a shredder that recycles large household waste and prevents clogging of sewer pipes. The simplest installation is capable of raising water to a height of 5-7 m and transporting it 100 m in a horizontal plane.
Monoblock centrifugal pumps of the NB series are distinguished by a one-way suction system and are used in water supply, heating, ventilation, air conditioning and irrigation systems. The torque from the engine is transmitted to the rotor impeller, and fluid enters the central part of the unit. As the blades rotate, water or another carrier of thermal energy, in the case of a heating system, is thrown towards the outer elements of the housing and redirected to the outlet pipe under the influence of centrifugal force. The pressure values inside the system are regulated by a Grundfos level sensor.
Circulation pumps, presented by the series of equipment UP, UPS, UPSD, Alpha 2, are equipped with a wet rotor and are intended mainly for completing a heating system with a closed loop. Its operation is based on the centrifugal force generated by the impeller placed on the shaft. When water enters the central part of the rotating wheel from the suction pipe, it is thrown into the peripheral sections of the unit.The advantage of the equipment of this series is the automatic cooling of the rotor, which rotates directly in the pumped medium. Repair of a circular heating pump with a wet rotor is still recommended to be entrusted to professionals.
In the segment of self-priming equipment, the leader is Grundfos MQ 3-35, which is used in a pumping station with a diaphragm expansion tank. The circulation of water is stimulated by an increase in pressure due to the centrifugal force arising from the rotation of the impeller. When it is displaced from the peripheral compartments of the unit into the pressure pipeline, the pressure in the central part of the impeller decreases and the liquid enters the pump casing. Such models are used to increase pressure and as part of pure water supply systems (drinking or technical).
Circulation pump device Grundfos
As a rule, pump breakdown occurs suddenly and is mainly caused by incorrect operation, which also needs to be given a little attention. Installation of Sololifts, for example, and similar high-performance equipment and the first start-up should preferably be entrusted to specialists.
Before connecting a submersible or surface pump to the power grid or to a hydraulic accumulator, it is necessary to check whether there is liquid in the area of the intake device and in all pipelines of the system - with a "dry" start, the pumping station will fail with almost 100% guarantee. The volume and temperature of the water to be pumped must comply with the performance specifications and the manufacturer's recommendations.
When the pump is idle for a long time, for example, when used in a country house or in a non-residential country house, once a month it must be turned on for 15-30 minutes to prevent oxidation of moving parts.
Despite the differences in design and principle of operation, most types of pumps are characterized by the following types of problems:
- lack of torque;
- premature spontaneous stop of work;
- increased noise level;
- increased vibration;
- insufficient pressure;
- stop after the start.
The lack of torque, despite the fact that the unit is humming, indicates shaft oxidation as a result of prolonged downtime of the equipment or contamination of the system with foreign insoluble or coarse-grained elements in the composition of the pumped liquid. In both cases, cleaning can eliminate the malfunction; less often, measurement of the rotor shaft or the entire engine is required. If the pump does not rotate and does not make noise when switched on, it is necessary to check the parameters of the power supply and voltage.
When the pump shuts down arbitrarily shortly after starting, the problem is most likely caused by excess lime and salt mass in the space between the rotor and the starter. The problem is also solved by cleaning, which requires prior shutdown of the system and dismantling the engine.
A high noise level when switched on indicates the presence of an excess amount of air in the pipelines, which is sufficient to release with a simultaneous increase in the inlet pressure. Sololift repair is not required in this case.
The increased vibration level is due to the fact that the bearing, which the pump is equipped with in some models, has become unusable and needs to be replaced.
Pressure defects occur when the viscosity of the pumped liquid is higher than the capacity of the pumping station, which is eliminated by replacing the clogged filter. Another reason is an incorrectly implemented three-phase connection. This is also the reason for the shutdown of the equipment almost immediately after its start-up.
The device of the pumping station Grundfos
The causes of breakdowns also include uncontrollable external factors - freezing of liquid in pipelines in the event of insufficient insulation or abnormal climatic phenomena and water hammer during a "dry" start.
to the menu ↑
Repair of the Sololift pump, as well as the repair of a Grundfos pumping station for any purpose, can be done independently, having previously identified the source of the problem.
Equipment diagnostics involves several stages:
- start the pumping station, evaluate the level of noise and vibration;
- check the pressure indicators;
- make sure that the motor does not overheat during operation;
- check the presence and quality of lubrication of the nodal joints;
- make sure the integrity of the structure and the absence of leaks;
- inspect the box to ensure that the terminals are securely seated.
If you are confident that the malfunctions are not caused by lime deposits and contamination, overloading or operating at maximum capacity, the pump can be disassembled. When planning to repair the Grundfos pump with your own hands, make sure that the water is drained from the pipelines and turn off the system. Disassembly begins with the junction box and a visual assessment of the components. As a rule, such an inspection makes it possible to immediately detect a burnt out or worn out part. If not, we will continue to disassemble the installation.
The engine must be in an upright position during disassembly.... This will prevent the risk of oil leakage. To diagnose the trigger, an ohmmeter must be connected to the engine. This tool, when the handle is rotated, generates a voltage in the range of 200-300 V, sufficient to take readings on a resistance tester. Too high diagnostic data reaching infinity indicates an interruption of the operating phase, too low - an interturn short circuit. Self-adjustment of the operating parameters with such deviations is impossible.
to the menu ↑
Grundfos pumps are most often used to optimize the circulation of the water supply during the heating season or in closed autonomous heating systems. They help to distribute heat evenly in the room and thus make more efficient use of energy.
Grundfos pump device.
These pumps are resistant to voltage surges and have overload protection. They are produced by a Danish company, which provides a guarantee for their quality and guarantees sufficiently high performance. These pumps can be used both at home and in industrial buildings.
However, if this equipment breaks down, the heating system will stop functioning and will remain cold until repairs are carried out.
The most common cause of pump malfunction is the formation of deposits that settle on the walls and, as a result, prevent the machine from starting. This violation can be corrected by doing the repair yourself. If you decide to purchase new equipment, it will be helpful to fix the old one. This way you can use it as a fallback.
For repairs you will need tools such as:
- screwdriver;
- scraper (made of wood);
- hex wrench;
- circle and polishing paste.
The first step is to remove all excess deposits from the shaft and rotor.
Since the main cause of pump failure is dirt build-up, the purpose of repairs is usually to clean the machine. To do this, you need to remove all excess deposits from the two component parts - the shaft and the rotor. This can be done by first unscrewing the pump screws with a hex wrench and thereby disassembling the threaded connection that holds the motor and pump. Once you open it, determine how much rust has collected in it.
Depending on this, it can be removed with a cloth or scraper. In order to disassemble the washer, as well as the rotor with its impeller, it is enough to insert a thin screwdriver into the slots that are located around the support washer. You can determine for yourself how high the likelihood of new deposits forming on a given surface is. If it is smooth, there is much less chance of deposits forming. Now it can be processed with a grinding wheel.
After that, you need to inspect the stator. As a result of work, it can oxidize quite strongly, and in this case it can only be cleaned with a hammer.
For normal operation of the pump, it is necessary to polish its inner walls.
Special attention should be paid to the sensor. The dirt and rust that builds up on it over time often causes Grundfos pumps to lose their performance. As a result, their work may stop altogether. Therefore, the sensor must also be removed and cleaned of deposits. To do this, remove the cover from the control unit and disassemble the pump housing in two halves.
To remove the sensor itself, you must unscrew the screws using the wrench that comes with the pump. After loosening the screws, the sensor housing can be easily removed by hand. If this cannot be done due to settled dirt, you can pry it off with a screwdriver. Since this part is made of plastic, the manufacturer himself recommends cleaning it more carefully and using less aggressive materials. To do this, you can use a regular toothbrush.
In order for Grundfos to work again in normal mode, it is necessary to polish its inner walls. At the same time, the work can be facilitated if you use polishing tools, having previously fixed them in the drill chuck.
If a bearing is stuck in the pump, then it is necessary to disassemble it and try to turn the impeller.
In order to remove lime deposits, the system is filled with a solution of acetic acid and water, which are mixed in equal parts. Threaded connections can be sealed. This will help prevent pump leaks in the future. You can even use a bicycle tube pad for these purposes.
Sometimes the reasons for the pump stopping can be a jammed bearing, the lack of a water flow sensor, or a drop in pressure. To do this, it is not at all necessary to completely disassemble the pump in order to eliminate one of the above problems.
Try to simply switch the equipment to manual mode by removing the switch located on the junction box from the stopper and placing the handle in the middle position. This will allow the pump to run even when the tap is closed. But if this did not help him turn on, then it is necessary to disassemble the pump and try to turn the impeller. If it does not scroll, the pump cannot be repaired.
If the pump works only in manual mode, the cause of the breakdown is the flowing water sensor.
The breakage can be eliminated by replacing the sensor itself. Sometimes the pump stops working after turning off the water due to the fact that air accumulates in it. In this case, you can lower it by turning the central screw.
After completing all these operations or when completely cleaning the pump, it must be reassembled. This is done in reverse order.
If none of the above actions led to the resumption of the pump operation, the breakdown may consist in the failure of the winding of its motor or capacitor. Such a malfunction requires replacement of spare parts, which can only be provided by a service center. Otherwise, the only way out is to replace this device. In European countries, the average service life of these pumps is about 5 years. However, the water quality in Europe is better, so the lifespan can be shortened by a year or two.
Pump manufacturers such as Grundfos produce quality pumps that are characterized by high performance and long service life. But even high-quality equipment is susceptible to breakdowns in case of non-compliance with the norms of use or when periodic maintenance is not carried out. As a result - partial or complete cessation of the functioning of the apparatus.
Grundfos pumps are usually repaired by specialized workshops, which charge a substantial fee for their services. Moreover, the problem itself is not always worth the money spent.The solution may be to repair the Grundfos pump with your own hands, which is quite possible with certain knowledge.
The repair of Grundfos pumps depends largely on the type of pumping device. Depending on the type of device, the design, the most probable malfunctions and the way of their elimination differ. Among the main series of pumping devices manufactured by Grundfoss, the following stand out:
- borehole pumps of the SQ, SQE, SP series;
- drainage and well devices Unilift KP, cattle;
- circulating devices for heating UPS, UPSD, ALPHA2, ALPHA3;
- sewerage system Sololift and Sololift 2 WC 3;
Range of pumping equipment Grundfos
Each individual device implies its own peculiarities of repair and maintenance.
to the menu ↑
Downhole tools such as SQ and SQE operate at great depths, where the bottom water can contain a high percentage of abrasives and silt. Therefore, the most common failure in such devices is contamination of the impeller and failure of the check valve. As a result, the device may not turn off after the end of work, or there is no pressure in the line. The solution to the problem will be to disassemble the pump and replace the check valve. In this case, it will not be superfluous to clean the entire working chamber.
Another common problem with the SQE series is air ingress into the system. As a result, the pressure level is disturbed, and the device turns on and off by itself. In this case, the power is turned off, the filters and the impeller are checked for contamination, then air is released from the line.
Also, a rather serious malfunction of a pumping device of the SQE type is increased vibration during operation. Such a problem can lead to too much silting of the source, which can make it unusable. Vibration occurs when the impeller is not centered. This happens when the fastenings on the housing are unevenly tightened, or the shaft bearing has become unusable. The solution is to replace the bearing and adjust the rotor inside the chamber using a ruler.
To solve any of the above problems, it is necessary to disassemble the apparatus. The procedure is carried out in the following stages:
- The device is firmly clamped in a vice. It is advisable to clamp with pipe halves so as not to deform the body.
- Further, VD-40 is injected into the thread area, after which you can gently turn it. The thread is often clogged with clay and sand, which greatly complicates the unwinding process.
- The rotor is removed from the working chamber.
Such disassembly is sufficient for cleaning the pump chamber and replacing the main components. The motor chamber is designed in such a way that it is not possible to disassemble it. Therefore, in case of damage to the motor winding, control electronics or electrical cable, the pump must be returned for repair.
After the device is disassembled, it is necessary to clean the impeller, bearing, valves in running water, and if necessary with a brush. You should also carefully inspect the mechanical seal between the working chamber and the engine compartment. There should be no obvious damage or tears on it. After the cleaning and replacement of components is done, the device is assembled and connected to the mains.
The device of the pumping station Grundfos
Assembly is carried out upside-down. In this case, the important points are the uniform fixation of both mounts on the body, correct thread adjustment, centering of the rotor and its fixation in the socket. If the filter at the suction ports is damaged, it must be replaced to prevent further contamination.
to the menu ↑
The Unilift KP and KRS series are designed for pumping melt water, sewage, septic tank contents, and drainage of swimming pools. At the same time, the simple design of such devices makes it easy to repair the Grundfos pump with your own hands.
Initially, drainage options are designed for difficult working conditions, therefore, breakdowns in such devices are quite rare. The main malfunctions that occur include:
- decrease in pressure;
- engine problems.
In the first case, there can be many reasons, but the main one is the presence of a leak. You should carefully inspect all joints for tightness, check on the outside and inside of the case wall for deformation. If no obvious problems are found, the piping, suction port and impeller should be checked for blockage. Blockages occur as a result of stagnation of dirty liquid inside the canal and its drying out. Cleaning is carried out under a strong pressure of water from a hose, and if necessary, a stiff brush is used.
In the second case, first of all, you should check the correct connection of the electric motor. Three-phase models have three working phases, and switching to another phase can solve the problem. If the problem is not resolved, the pump is disassembled further and the quality of the winding and wires is checked.
Before disassembling the device, it is imperative to turn off the device and check it for the ability to connect independently to the network. When disconnected from the mains, you can gradually remove the mesh filter of the device with a screwdriver. It is removed by uniform pressure along the entire groove at the junction with the body. Then, using a screwdriver, the case is rotated 90 degrees in the direction indicated on it and removed. This disassembly is sufficient to clean the impeller, filter and working chamber.
If after that the problem is not found, further disassembly takes place. Using a 13 key, the impeller retainer is unscrewed and it is removed. Further, the rotor nut is loosened. After completely loosening, the rotor is removed from the groove, and after it the stator can already be removed. After checking and cleaning all components, the device is assembled in reverse order. In this case, it is necessary to check the free wheel travel and the correct centering of the rotor. After complete assembly, it is necessary to connect the pump to the network and carry out a test run.
Circulation pump device Grundfos
It is possible to prevent the repair of the circulation pump, but for this it is necessary to carry out a monthly check of the device. For this, the device is turned on, and the inspector notes the following criteria:
- lack of strong vibration and extraneous noise during operation;
- lack of "punching" on the pipeline or the body of the apparatus;
- all nuts and bolts are tightened as much as possible and do not wobble;
- the engine operates in the optimal temperature range stated in the technical passport;
- there are no leaks between the units of the apparatus, and at the joints with the pipeline;
- all rubbing parts have grease.
If there is at least one of the problems, the device is turned off, dismantled, an internal inspection is carried out, and, if necessary, the main components are replaced.
The main problems that arise during the operation of circulation devices are:
- Running noise and the impeller does not move. The cause of this problem can be the ingress of solid particles into the rotor or oxidation of the mechanism. In this case, the water in the line is blocked, the accumulated air is released from it. Further, the fastening screws are loosened, and the motor with the rotor is removed. All hard parts are removed, and the rotor is turned for a while by hand or a screwdriver until the rust is removed. To prevent re-breakage, a filter is installed on the pipeline.
- Lack of noise and rotor rotation. In this case, the problem lies in the correct connection to the network, or in the weak voltage. It is necessary to check the condition of the power supply with a tester, it is also necessary to inspect the correct connection of the contacts and the functionality of the fuse.
- The pump turns on normally, but turns off after a certain period. Repair of the heating circulation pump in this case requires a complete disassembly of the rotor and stator.The reason for this phenomenon is deposits (lime, scale) on the connection between the rotor and the engine. Both mechanisms must be removed and cleaned thoroughly.
- High vibration level. The cause of this problem is a worn-out bearing at the connection of the rotor to the motor. In this case, a replacement is required.
to the menu ↑
The peculiarity of using Sololift pumps is that they are installed in places that are below the main sewer line. Therefore, the pumping station pumps the effluents under pressure forcibly. But, despite such serious tasks set for Sololifts, there is nothing difficult in the installation of a sololift and it can be done independently. And the correct installation of the device is the key to long-term operation and excludes the prompt repair of Sololift. Correct installation of the unit includes the following points:
- the device is installed exclusively on anti-vibration material;
- only those elements that come with the model are used as fasteners;
- the minimum distance to walls and other plumbing fixtures must be at least 10 mm;
- when connecting to a sink, a filter must be installed on the inlet pipe, and in the case of using on other plumbing, a check valve is required.
Cleaning the Grundfos Sololift installation
As for the repair of the Sololift pump, there are many service options, depending on the specific problem. Most often, the following malfunctions occur:
- The engine does not start when the water reaches the start level. If there is such a problem, first of all, you need to check the presence of power in the network and the correctness of the connection. The fuse may also blow. This is caused by damage to the cable or motor. In this case, the main components are inspected, after which the fuse is replaced. If none of the above helps, you need to check the operation of the pressure switch.
- The motor is noisy but does not turn the impeller. There can be two reasons for this: the wheel is too jammed, or the engine is faulty. In the first case, the repair of the Sololift pump consists in restoring the mobility of the working body. The second option can be corrected exclusively at the service center. There are such centers in Moscow, Sergiev Posad, Orel, Tula, Kaluga, as well as in other regions of the country.
- The engine does not shut off by itself. The reason is a leak in the pipeline, an inoperative check valve, or a faulty pressure switch. Replacement of the corresponding part is required.
- Slow pumping out of fluid when all units are operational. First of all, it is necessary to check the tightness of the case and the absence of leaks on it, replace if necessary. Clearing a blockage in the system can also help.
Any pump is susceptible to damage. It is necessary to take into account their constant contact with various kinds of liquids. Therefore, even pumps from the well-known Danish company Grundfos are not insured against stopping due to failure. It is the water that causes the loss of performance. Depressurization due to worn out glands or seals can create a breakdown in the insulating components of the pump. To avoid trouble, you should periodically inspect the pump.
It is better to entrust the repair to professionals. However, no one says that in some cases, some types of restoration work can be carried out at home. More on this later.
Before providing first aid to the pump, you should familiarize yourself with the most common causes of pump failure:
- The use of the pump for purposes not foreseen by the manufacturer.
- Incorrect installation of the unit.
- Voltage surges - from low to above required.
- Pumping liquids containing large solids.
- Ignoring the correct fixation of the cable.
The grundfos pump can also fail due to the failure of its pump. In this case, the only correct solution would be to completely replace the broken part of the device.Do not forget that in the process of replacing any parts of the pump, it is almost completely disassembled. The main task will be not only to assemble everything in the reverse order, but also during the assembly process not to harm the pump with anything else.
The best repair option would be to contact a service center, where the restoration of the device's performance and maintenance is always at a high level. With the help of the necessary tests and stands, the following will be carried out in a quality manner:
- breakdown diagnostics;
- replace broken components with original ones;
- will carry out post repair tests.
Test benches provide the ability to:
- check hydraulics indicators;
- measure the resistance level of the insulating material of the electric motor;
- test the cable supplying power to the motor.
Using a variety of tools of the service center it is easy:
- replace the rotor of the electric motor;
- change worn-out bearings that require pressing out;
- change the top cover of the engine;
- clean the pumping part of the pump from contaminants.
The pumps are taken out of working condition, various deposits settling on the walls. It is they who prevent the device from starting. Your hands will always help to get rid of the problem, even if they are not golden.
Getting down to the crucial moment, prepare the necessary working tool. You will need:
- hex key;
- wooden scraper;
- polishing paste;
- polishing wheel;
- cross and flat screwdrivers;
- hammer (medium and small).
The primary repair task will be to clean the rotor and shaft from deposits accumulated on them. Armed with a hex wrench, unscrew the screws on the pump. This brings us to the threaded connection holding the pump and its motor. Such repair of grundfos pumps is not the pinnacle of genius. After opening, you will be convinced that there is an impressive amount of rust.
It can be easily removed with a scraper or strong cloth. A small, flat screwdriver will help to get to the rotor and its impeller. It must be positioned in the grooves along the diameter of the support washer. The surface that has opened will need to be carefully sanded, which will eliminate the possibility of new dirt adhering. To do this, use a previously prepared grinding wheel.
At this stage, you can proceed to inspect the stator itself. Its main enemy is oxidation. The working tool here will be a hammer, with which it is necessary to tap the surface and knock down the deposits by vibration.
Rust in tandem with dirt is favored by a controlled pressure sensor. In this context, the maintenance of grundfos pumps is extremely important for stabilizing the functioning of the device and its operation in general. To do this, you will need to disassemble the pump into two parts by removing the cover of the unit.
The sensor can be removed by hand using the keys specially made at the factory, which are included in the standard package of the product. In some cases, it is required to lightly pry it off with a screwdriver, when the accumulated dirt impedes the removal process. The manufacturer requires it to be cleaned with soft tissues without undue effort. The best option would be to use an ordinary toothbrush.
Danish pumps are always efficient if they are repaired and serviced in a timely manner. Therefore, special attention should be paid to polishing the inner walls. To eliminate the laboriousness of the process, the work is facilitated by the use of polishing tools, which are most convenient to use fixed in the drill chuck.
Bearing wedging is also possible. To break it, sometimes it is enough just to turn the impeller. Limestone deposits are no less annoying. Cleaning takes place by means of preparing a vinegar bath. You will need to mix this acid with water in equal proportions. Try to pay attention to the threaded connections as well. Seal them if possible using a bicycle tube to create spacers.
Other breakdowns are not excluded. Stopping the pump is possible due to:
- seized bearing;
- inoperative sensor for the presence of a water flow;
- lowering the pressure.
In such cases, do not disassemble the pump to the smallest detail. Just put it in manual control mode. To do this, remove the switch, which is locked and located on the pump distribution box. Such actions can make the pump work even if the drain valve is closed. Otherwise, you will have to turn the impeller manually. If you fail to rip it out of place, then a complete replacement of the element will be required.
Functionality is guaranteed by regular servicing of grundfos pumps. Sometimes there are exceptions to the rule. If the device fails to operate in the process automation mode, but works on manual control, try replacing the sensor for fixing the movement of water. The unit may have stopped listening to commands through the accumulated air in the system. Bleed it off by turning the center screw.
Problems are possible in any pumps, even circulation ones. Once you have decided to personally eliminate any potential problems, always try to assemble the pump in such a way that after the assembly is complete, there are no unnecessary parts left on the workbench. Stick to the reverse order of assembly.
Good afternoon, members of the forum!
In early summer 2011, he acquired a Grundfos MQ 3-35 pumping station. In connection with the repair of the boiler room in the house, the pumping station was connected only in February 2012.
The pumping station was supposed to be used to increase the pressure - the house is connected to the village water supply. At the inlet of the water supply system to the house, depending on the time of year and day, the pressure can vary from 1 to 3 atmospheres.
When you turn on the pumping station and Without water intake (i.e. taps on all consumers are closed) the pumping station starts pumping water and stops pumping at a pressure of about 7.5 atm. I cannot name the exact pressure at which the station stops pumping water, because the manometer is designed for 6 atm. and it rolls over. According to my observations, the shutdown of the pumping station occurs at a pressure of over 6 atm. regardless of the pressure at the inlet of the water supply system to the house - whether it is 1 atm. or 3 atm.
When you turn on the pumping station and in the presence of the water intake pumping station adds its own 3 - 3.5 atm. to the water pressure at its inlet. There are no complaints here.
Brief description of the pumping station connection diagram:
- Prolipropylene inlet DN 25.
- inlet ball valve 1 "
- "Oblique" filter 1 "
- ball valve 1 "
- pressure gauge
- mechanical wash filter 1 "
- pressure reducer 1 "(set at 2.5 atm., the goal is to provide at the outlet of the pumping station no more than 6 atm.)
- pressure gauge
- ball valve 1 "
- pumping station MQ 3-35 with a standard check valve installed on the receiving side
- hydroaccumulator 80 liters.
- further branching with polypropylene DN 20 to the cold water collector and to the boiler
- a pressure gauge on the cold water manifold (it was on it that the readings were taken during the operation of the pumping station).
Can you please tell me if it is normal that when the water intake is closed, the station builds up pressure over 6 atm?
Earlier I read (if I am not mistaken, on this forum) about the algorithm of the MQ 3-35 station: switching on according to the flow, or if the pressure at the station outlet is below 1.8 atm., Switching off at the outlet pressure of 3.5 atm.
3k, but it still leaks in the area of the drain plug and by replacing the plug this is not treated - the rusty body of the pump. The second filled in his own automation. There are 2 more Chinese who work outside in the rain and sun with much more aggressive water from the wells. The Chinese have been alive and well for 5-6 years. In general, if you do not want to throw out 24k in order to once fill the house with water, do not mess with it.
P.s. they are not silent, they are quiet. first time. But the Chinese were quieter, surprise.
He took and supplied clean water to the house from a container, which was filled with a borehole pump by driving water through all filters.
In two cases, from the failure of the automation, and the continuous operation of the NS, the oil seals were leaking, flooding both the engine and the automation unit with water.
P.S. Installed normally, with a normal check valve in the suction line.
he was too good for this to last long.
Later, during disassembly, I found out that the cause of the breakdown was the water flowing through the sealing collar of the encapsulated electric motor, as a result, the winding shorted. The cuff was either worn out or melted, but it was definitely not of the best quality. Therefore, if you decide to take such a pump, be careful. Despite the fact that in operation it is written “does not require maintenance under normal conditions”, if I were you, I would now check the engine for leaks every 3 months.
3300 UAH). I phoned five more service centers (including Kiev) - the result is the same - buy a new one and that's it.
I came to the service for the repair and rewinding of engines. They said that I was not the first. Approximately every 2 months they bring in such stations (MQ-3-45 or MQ-3-35) with the same problem. It's worth rewinding the motor
UAH 500 But there is a reason why they cannot be repaired.
The engine is housed in a stainless steel glass (protective casing, it is also the engine body). And in this glass shells and cracks form through which water enters the engine. (probably a very "high quality" metal). The result is a short circuit in the working winding.
Because of this problem, there is no point in rewinding. And to repair at a Grundfos service center - it's cheaper to buy another (but not Grundfos anymore).
3k, but it still leaks in the area of the drain plug and by replacing the plug this is not treated - the rusty body of the pump. The second filled in his own automation. There are 2 more Chinese who work outside in the rain and sun with much more aggressive water from the wells. The Chinese have been alive and well for 5-6 years. In general, if you do not want to throw out 24k in order to once fill the house with water, do not mess with it.
P.s. they are not silent, they are quiet. first time. But the Chinese were quieter, surprise.
He took and supplied clean water to the house from a container, which was filled with a borehole pump by driving water through all filters.
In two cases, from the failure of the automation, and the continuous operation of the NS, the oil seals were leaking, flooding both the engine and the automation unit with water.
P.S. Installed normally, with a normal check valve in the suction line.
The Grundfos Mq 3-45 pumping station is easy to install as it is sold fully assembled. For seven years I have been working with Grundfos equipment, and more than once I had to deal with the fact that buyers independently installed a station for lifting water from a well from a well or a well without a check valve with a grid, and therefore the station quickly failed.
This pumping station is one of the most reliable models of pumps for water supplying a private house, providing watering for a vegetable garden and a garden, increasing the pressure in an existing water supply system. In case of overheating or dry running, the pump automatically stops and during the day tries to start again every half hour.
he was too good for this to last long.
Later, during disassembly, I found out that the cause of the breakdown was the water flowing through the sealing collar of the encapsulated electric motor, as a result, the winding shorted. The cuff was either worn out or melted, but it was definitely not of the best quality. Therefore, if you decide to take such a pump, be careful. Despite the fact that in operation it is written “does not require maintenance under normal conditions”, if I were you, I would now check the engine for leaks every 3 months.
3300 UAH). I phoned five more service centers (including Kiev) - the result is the same - buy a new one and that's it.
I came to the service for the repair and rewinding of engines. They said that I was not the first. Approximately every 2 months they bring in such stations (MQ-3-45 or MQ-3-35) with the same problem. It's worth rewinding the motor
Video (click to play). |
UAH 500 But there is a reason why they cannot be repaired.
The engine is housed in a stainless steel glass (protective casing, it is also the engine body). And in this glass shells and cracks form through which water enters the engine. (probably a very "high quality" metal). The result is a short circuit in the working winding.
Because of this problem, there is no point in rewinding. And to repair at a Grundfos service center - it's cheaper to buy another (but not Grundfos anymore).