If you are faced with a breakdown of a water heater, do not panic - our article will help. Malfunctions of the "Neva" gas column can happen for various reasons, but typical ones can be distinguished. We will tell you how to repair Neva models at home.
Important! If your equipment is under warranty, do not disassemble it yourself, otherwise you will lose free service.
How to understand the location of the water heater components? Don't worry, the diagram will help you. It is based on Neva speakers.
Metal casing.
Control window.
Gas flow regulator.
Water regulator.
Digital indication of temperature.
Cold water connection (thread G 1/2).
Hot water outlet.
A branch pipe for connecting to a gas line (cylinder).
A branch pipe for the removal of combustion products is connected to the chimney.
The foundation. Back wall.
Installation holes.
6, 7, 8 - continued, nozzles, as indicated above.
12 - water unit.
13 - water regulation rod.
14 - drain plug.
15 - microswitch.
16 - control unit.
17 - gas unit.
18 - fuel adjusting rod.
19 - solenoid valve.
20 - collector.
21 - collector fixing screws.
22 - burner nozzles.
23 - spark plug.
24 - ionization sensor.
25 - copper heat exchanger.
26 - output to the water unit.
27 - outlet to the gas unit.
28 - mounting bolts.
29 - thermal relay.
30 - thermometer.
31 - gas outlet device.
32 - thrust sensor.
33 - mounting brackets.
34 - battery compartment.
Having understood the design, you can start troubleshooting.
Video (click to play).
The indicated malfunctions and options for their elimination are suitable for all models produced by "Neva", including: 4510, 5514, 4511, 4513, 4510M, 4513M, 4610, 5611. We will separately consider error codes and breakdowns on the example of some models.
You will need to remove the cover to access the inside of the instrument. How to do it yourself:
Be sure to shut off the water and gas supply.
Pull the adjusters towards you and remove.
Some models have a screw behind the adjuster. Unscrew it.
Disconnect the temperature indicator wiring.
Remove the casing securing bolts.
Pull the trim towards you a little, then up.
You can start repair work.
Reasons for the appearance and ways of troubleshooting.
The burner does not ignite. No spark... In this case, the temperature indication does not work when the mixer is opened.
Weak water pressure. If the pressure in the tap is small, you need to wait until the flow is restored. The installed model may be too powerful for your plumbing. Also check the adjustment toggle switch, set to the maximum value. For frequent pressure problems, it is recommended to install a circulation pump.
The batteries are dead. Some users are confused by the scoreboard. If the display is lit, the user thinks the batteries are ok. But lighting a candle requires more current. It is important to choose high quality batteries.
The manufacturer recommends installing LR20 (alkaline) batteries. Therefore, salt cells such as R20, which are sometimes used, will not give stable performance. An alternative to the LR20 is the CR20, but the cost is much higher. To replace, turn the knob in the battery compartment.
Expert Advice: Check food contacts more often. The technique works with water, so the contacts are susceptible to corrosion and chemical deposits.
Defective flow sensor. Inspection and replacement required.
Wear of the rubber membrane. This can be understood by visual inspection.Open the mixer and see how the pusher works. If it does not move, then the membrane is damaged or stretched (marked with a blue arrow in the photo). Red arrows mark places that are susceptible to leaks.
You can remove the water part together with the gas part. The dismantling procedure is marked with letters:
a - after turning off the fuel supply, the supply hose is unscrewed.
b - the cold water nut is loosened.
c - the nut of the water block and the radiator pipe is unscrewed.
d - the wiring of the solenoid valve is disconnected.
d - the microswitch loop is disconnected.
e - the bolts of the flange connection are unscrewed.
Broken electronic board requires a call from a specialist.
Breakdown on the body of the device. A clicking sound is heard, as when a spark is formed, but no ignition occurs. This means that the insulation of the candle is broken. If defects are found during inspection, a serviceable part must be supplied. Also, the cause of the breakdown is a violation of the tight connections of the cable with the control unit. Return the cable to the socket.
The display allows the user to see the fault code. Self-diagnosis of the column gives a digital value in case of a malfunction.
E0 - the boiler shuts down. Fuel does not flow into the system. Check the gas valve; the supply may have been shut off for a short time.
Error E1 - the control board does not receive a signal from the flame sensor. More than a minute passed.
Air in the gas pipeline. This happens when the device is turned on for the first time or when the device is turned off for a long time. Open and close hot water several times until the burner ignites.
The fuel supply valve is not fully open. Unscrew the tap.
Insufficient pressure in the gas line.
The tank has run out of fuel. The cylinder needs to be replaced.
Violation of the wiring between the water unit and the flame sensor, solenoid valve. Examine the loop for damage to the insulation.
The electrode has moved out of place, does not reach the burner. Return the part to its original location.
Soot is present on the electrode and flame sensor. You can clean the parts with a brush.
The contacts between the spark plug and the high-voltage wire are removed.
The nozzles are clogged with soot.
The burner must be removed for cleaning. Disconnect the wiring and unscrew the nipple nut. Unscrew the two manifold bolts, then do the same with the burner mounts. After dismantling, the holes are washed with a brush and soapy water. Reassemble after rinsing and drying.
E3 code - the solenoid valve was triggered earlier than the signal from the flow sensor.
The valve is defective. A new element is being installed.
The electronic unit has broken. Diagnosis is carried out by a specialist.
Error E7 - after 7 attempts to ignite, the equipment still does not light up or goes out.
Open the fuel valve as far as it will go.
The ionization sensor has moved or soot has accumulated on its electrode. It should be in the flame area, near the burner. Cleaning is done with a brush.
The electrical valves are out of order.
The water or gas block has boiled. Replacement of elements.
Error E8 - the thrust sensor has been triggered. Causes:
The sensor is broken. See if the contacts are tight, change the part.
The chimney is clogged with debris or soot. If you cannot clean the passage with your own hands, contact your utilities.
L0 - not enough fuel is supplied for normal operation. What happened:
Weak water pressure. The line pressure acts on the diaphragm, which opens the valve. Wait for the flow to recover, adjust the toggle switch, or descale the radiator. How to do this is described in the article on cleaning and repairing a gas column heat exchanger.
The temperature at the controller is too low. Increase your metrics.
The pressure in the gas line exceeds the permissible limits. Install the reduction gear.
Such malfunctions are typical for the Neva 3208 and Neva Transit models.
The device works for a while, then turns off... Draft problems that can arise from blockages or improper installation of the hood.
Typical user mistakes:
The ventilation pipe is installed too close to the wall of the chimney, normal draft is not generated.
Another device or hood is connected to one pipe.
There is another window on the level with the ventilation of the column.
The column does not light up or immediately goes out... The temperature sensor is triggered.
Overheating has occurred.
The part is out of order.
The membrane is stretched.
Flame sensor does not work.
Display does not work:
The thermal sensor is out of order. Need a replacement.
Contacts broken.
Display defective.
The equipment is very noisy:
Twist the water regulator. Reduce the head.
The gaskets in the pipe joints protrude out of place. Replace the gasket.
You have learned the structure of the Neva water heater, its typical malfunctions. You can start fixing the problem. We hope our article helped you get the technology back on track.
The geyser NEVA 4511 is a compact water heating unit with a rated power of 21 kW. This indicator is quite enough to provide apartments and country houses of various sizes with hot coolant.
The geyser NEVA 4511 is a budgetary and fairly compact technique that is convenient and easy to use. The burner flame is ignited with batteries. The built-in LCD display informs the user about the key parameters of the unit operation. The design provides for the presence of a water cooling system for the combustion chamber. The modest dimensions of the unit make the column invisible in any room, which can be considered as an additional plus.
The device of the NEVA 4511 geyser is quite simple, but at the same time modern technical advances in efficiency and safety are not alien to it. This model is manufactured in accordance with domestic and international requirements for equipment of this kind. This suggests that the manufacturer takes a responsible approach to the design of water heating equipment, taking care of both the consumer and his reputation in the international market.
Speaking about the device of the NEVA 4511 geyser, it should be noted that the device is designed for easy operation. The technique starts automatically when the hot water tap is opened and dies out when the user turns off the tap. With the inexpensive and reliable 4511 series NEVA speaker, you can forget about the burning wick, which can become a serious hazard. The fact that the column is fired from batteries ensures the durability of the main components and prolongs the life of the unit as a whole.
Let's highlight a number of advantages with which this column is able to please a potential buyer:
Compactness and ergonomics. The dimensions of the unit are very modest and amount to 565x290x221 mm. At the same time, the entire structure is designed in accordance with the best ergonomic standards - a convenient control panel and a minimalistic design are characteristic features of the model.
High performance. The design of the NEVA 4511 geyser took place taking into account the fact that the equipment will operate mainly in the difficult conditions of the Russian climate. Because of this, it has been made tough, strong, durable, and highly productive. In addition, the 4511 model is adapted to work in conditions of low pressure in the water supply system, which can be considered an important plus for users from our country, where interruptions of this kind occur quite often.
Safety and reliability. The unit is equipped with a flame control sensor, which reduces the risk of an unforeseen accident hundreds of times.
It is obvious that any domestic water heating equipment has a number of disadvantages. In this regard, the NEVA 4511 model is also far from ideal. With a rated power of 21 kW, it produces up to 11 liters of hot coolant per minute.
Experts are sure that the equipment "will not cope" with its work if water is taken from two points at the same time.For example, washing the dishes while someone in the household is taking a bath can be difficult. The power of the unit is not enough to provide two points of water intake with sufficient hot water. In addition, the design does not provide for a smooth flame modulation system, which cannot be said about more modern speakers.
Very often on the network you can find requests like "geyser NEVA 4511 do-it-yourself repair". That is why typical malfunctions and methods of self-elimination will be given below.
If the column does not light up, there can be many reasons for this. Among them:
Lack of traction in the ventilation system. The problem is solved by cleaning the ventilation duct.
Problems with the power supply (batteries dead). The problem is solved by replacing the power supply.
Low water pressure in the water supply system. You can independently wash the filters, clean the column from combustion products and replace the membrane at the water unit. If the problem persists, contact the utility service with appropriate inquiries about the cause of the low pressure in the system.
Incorrect balance between cold and hot water. In this case, you need to adjust the temperature of the coolant produced by the column so that you do not have to mix cold and hot water.
As a rule, the reason for this is that the ventilation is clogged, the supply batteries are discharged, the gas is supplied too intensively, or the nozzle is clogged. In all these cases, it is recommended to consult a specialist. On your own, you can replace the batteries or clean the ventilation ducts.
If the column turns on, but it does not heat the water to the required temperature, there may be several reasons for this. First, your equipment may not meet your power needs. Secondly, if the column is clogged, it loses in performance, and this must be taken into account. You can adjust the hot coolant supply valve and call a specialist from the service center who will clean the equipment.
The fact that the repair of the NEVA 4511 gas water heater can be done by hand makes this model a very attractive unit for the Russian buyer. At the same time, the column is inexpensive, has been functioning for decades and does not require special care during operation. Being a universal domestic water heater, NEVA 4511 is ideal for use in Russian houses and apartments.
Warning. This section is intended for specialists who have the appropriate permission to repair gas equipment! If you repair yourself during the warranty period, the warranty is void!
This article will focus on malfunctions of Neva speakers (models 4510, 4511, 4513, 4510M, 4513M, 4610, 5611). Many Chinese speakers, such as Vecktor or Oasis, and not only Chinese ones, work on the same principle as the Neva, so the remedies below apply to them as well. But, please be more careful, the photographs in the article show details for the Neva columns.
No spark when hot water is opened.
When the hot water tap is opened, there is a spark discharge, but the column does not ignite.
Check if the hot water tap in front of the column is open.
There is no gas in the main gas pipeline. You need to call the service to fix the problem.
Check the serviceability of the EMC. Connection contacts may be broken.
Correct the spark plug, it is possible that the discharge does not reach the flow of the gas-air mixture (about 5 mm from the end of the plug to the burner).
When using a column from liquefied gas, it is necessary to check the gas supply in the container (cylinder).
Weak spark from spark plug electrode. It is required to clean the contacts of the battery compartment or to completely replace the ignition elements (batteries).
The column will run for a while and turn off.
Poor cravings.Thrust sensor triggering. It is necessary to clean the chimney or check the tightness of the exhaust pipe connection on the column pipe.
Overheating of water (outlet water temperature is more than 90C, triggering of the limit temperature sensor). It is necessary to use the column control knobs to reduce the gas consumption and increase the water pressure.
Replace the membrane of the water unit.
There is no signal from the ionization sensor (flame sensor). In this case, the burner works for no more than 7 seconds, and spark discharges from the spark plug do not stop. It is necessary to restore contact with the sensor, correct its position (if it touches other elements of the burner) or replace it.
The water temperature reading is not shown on the column display.
Defective water temperature sensor. It needs to be replaced.
Check the connection contacts of the display itself to the ignition unit. If there is no result, replace the display.
The water does not heat up well.
Reduce water pressure.
It is required to check the heat exchanger for the presence of scale on its walls. If necessary, remove it, rinse with Solita. It is also necessary to clean the column burner from dust and soot on its surfaces.
Insufficient gas pressure in the line - call the service to eliminate the causes.
Repair or replacement of the water unit is required.
The flame of the burner of the column is yellow and weak, with smoky tongues.
1. It is necessary to clean the column burner from dust and soot on its nozzles and internal surfaces.
Excessive noise of water during the operation of the column.
It is necessary to reduce the water pressure with the column adjustment knob.
Extrudes gaskets at the joints of the water pipes. Replacement of gaskets is required.
The burner continues to operate even when the hot water tap is closed.
The stem of the gas unit is seized (it is very difficult to move the stem manually). It will be easier and safer to replace this unit.
It is required to replace the membrane of the water unit.
These were the most common malfunctions of the Neva speakers. We hope this article helped you troubleshoot your water heater.
the wick burns very strong during the night heats up the pipes with water when the water is opened after a few seconds there is boiling water for the daughter-in-law of the children sprinkles when they wash their hands the plastic tubes of the teapot how to reduce the wick
Hello, tell me the model of the column.
remove the front cover and on the gearbox you will see a yellow bronze screw for a screwdriver. twist it smoothly while the wick is working.
WHY WHEN THE WATER REGULATOR IS ADDED IT GOES OUT
Nikolay, to open the gas valve, you need a certain water pressure in the water valve. As the flow of water increases, you decrease this pressure and the gas valve closes.
The situation is as follows: when the hot water tap is opened, the flame does not light up for 4 seconds, and then a strong pop. The flame ionisation sensor is not working. Previously, after three seconds there was no flame, the gas supply to the burner stopped. This rarely happens. Neva 4501
Hello Dmitry. The ionization sensor has nothing to do with it. There are several probable reasons: 1. Check batteries (replace if necessary) 2. Check the ignition plug, its position relative to the burner (5mm gap) 3. Poor traction is possible (gases accumulate and therefore cotton occurs) 4. Clean the burner itself from soot 5. Unlikely, but still, the control unit itself requires replacement.
Hello. Column Neva. There is a slight leak in the area of the microswitch. What do you recommend to do?
Since the Neva 4511 series geyser is one of the most common models, the topic of its maintenance and repair is of interest to many users who are accustomed to doing such work with their own hands. Indeed, these open-chamber instantaneous water heaters can often be brought back to life without the need for service personnel. Let's look at what malfunctions occur during the operation of these units, as well as ways to eliminate them.
It is impossible to independently repair a household appliance without knowing how it functions and what it consists of.Unlike old-style water heating devices, this series of gas water heaters is equipped with a controller and electric ignition, which made it possible to remove a constantly burning igniter. The rest of the design remained fairly simple and maintainable. It consists of the following basic elements:
Housing with hinges for wall mounting.
The diffuser is a collection of combustion products with a chimney pipe.
Copper heat exchanger.
Gas burner device.
Water node.
Membrane actuator (so-called frog).
A gas valve with an electromagnet, connected by a common stem to a water unit.
Controller.
Microswitch for power supply to the electronic unit.
Water supply pipes.
Ignition electrode.
Flame detector (ionization).
Additional electrode for ignition of the burner.
The valve is a flow regulator.
Adjustment of the intensity of combustion and heating temperature.
Connection of a draft sensor installed inside the diffuser.
The diagram above shows the device of the Neva gas column with numerical designations of parts corresponding to the list.
Automatic switching on and heating is controlled by the water unit together with the controller, and the solenoid valve connected to the draft sensor is responsible for the safe gas supply. The algorithm for the operation of a water heater looks like this:
After opening the hot water tap at the inlet of the "frog", pressure arises, which acts on the rubber membrane of the assembly. It moves the stem that opens the gas valve and closes the microswitch contacts.
When the electrical circuit is closed, battery power is supplied to the controller. He gives 2 commands at the same time: open the solenoid valve for gas passage and create a spark on the ignition electrodes. As a result, the burner ignites.
The flame sensor detects the appearance of fire and transmits a pulse to the electronic unit, which interrupts the sparking. The heater switches to operating mode.
When the valve on the mixer is closed, the pressure in the network disappears and the spring throws the frog diaphragm back, at the same time closing the mechanical gas valve. The limit switch is triggered and the controller loses power, and with it - the electromagnet. The fuel supply is interrupted and the burner is extinguished.
The fundamental point. The solenoid valve is connected in one circuit with the draft sensor (pos. 16 of the diagram). If, for various reasons, the draft in the chimney disappears or weakens, the sensor will heat up and open the circuit, de-energizing the electromagnet. The latter will return to the closed position and cut off the gas supply to the burner.
To exclude possible overheating of the water in the heat exchanger, the manufacturer has implemented a simple technical solution: a temperature sensor connected to the controller is built into the pipeline. If the flow heats up to a critical level (about 90 ° C), then the gas supply will automatically stop and the burner will go out. The structure and principle of operation of the Neva 4511 column is shown more clearly in the video:
In order to fix the malfunction of the Neva gas column with your own hands, you need to diagnose it correctly. Over the years of operation of the water heating apparatus, one part of the parts wears out and requires replacement, the other - periodic maintenance. In this case, a variety of problems arise, characterized by certain symptoms. We propose to divide all emerging problems into groups according to the following criteria:
the burner does not light up when opening the tap of the DHW system;
after working for 5-10 seconds, the unit shuts down;
the flow heater starts up and functions properly, but does not heat the water well;
other problems.
Advice. Most often, the rubber membrane of the water unit fails in gas water heaters - it stretches, cracks or breaks. This is a consumable part that should always be kept in stock. A sample of the part is shown in the photo.
When the water heater does not react in any way to the inclusion of hot water, you need to perform the simplest action - check the condition of the batteries and the contacts of the battery compartment (they can oxidize). Clean them with sandpaper, install a new set of batteries, and then try firing up again.
An important point. The luminous display of a household appliance does not at all indicate a full charge of the batteries, since it does not consume much energy. If the batteries are "hung up", then the voltage for triggering the electromagnet and sparking may not be enough. According to the specifications published on the official website of the manufacturer, the set of elements is enough for about 250 hours of operation.
Battery compartment location - bottom view of the device
Is the power supply ok? Then continue diagnosing the gas water heater using this algorithm:
Make sure that there is enough pressure in the piping to turn on the device. It is possible that someone accidentally closed the shut-off valve or control valve on the heater itself (right).
If there is a strainer on the incoming water supply, check its condition and clean if necessary.
Remove the front panel of the device and open the DHW tap, observing the stem. If it does not move under normal water pressure, the reason lies in the frog's membrane.
The stem has moved, released the switch button, but nothing happens? There is a problem with the electrical circuits. You need to check the microswitch and ring the other wires supplying the controller and solenoid valve.
Advice. When repairing the Neva gas water heater, accompanied by disassembling the unit, just in case, shut off the gas main.
To dismantle the front casing, it is necessary to remove the plastic handles from the control valves and disconnect the display connection connector. At the back, the panel is supported by 2 self-tapping screws located at the bottom of the device. Unscrew them and remove the cover by pulling it towards you and pulling it up.
To check the limit switch, you must disconnect the connector and ring it with a multimeter or lamp tester. When the button is pressed, the circuit must be open. As for the wiring, it rarely fails, unless you catch your eye on a fallen off wire, which is easily removed.
To replace the membrane in the Neva 4511 column, remove and disassemble the water unit together with the gas one, following the instructions:
Close the cold water and gas supply, unscrew both supply pipes with an open-end wrench. Also disconnect the copper pipe leading to the heat exchanger.
Disconnect the controller and microswitch connectors.
The entire water / gas block is fixed with 2 screws to the burner flange. Unscrew them with a Phillips screwdriver and remove the assembly.
Disassemble the frog and replace the membrane and with it the small O-ring shown in the photo.
Note. The replacement can be done without dismantling the whole block, but it is extremely inconvenient to perform the operation in this position. The described disassembly technology is also suitable for other models of gas water heaters - Neva Lux 4510, 5611 and so on.
How the membrane of an instantaneous water heater changes, see the next video:
When sparking is visible on the spark plug but the burner is idle, check the following points:
whether the spark electrode has moved relative to the nozzle;
whether the traction or overheating sensor that opens the solenoid valve circuit is out of order;
does it pierce a high-voltage wire onto the case;
spark has diminished due to plugged plug or battery discharge.
The electrode should be located directly above the nozzle of one of the burner sections at a distance of no more than 5 mm from it. A violation of the position of the candle is corrected by simple bending. Sometimes it is enough to clean the end of the electrode from soot to increase the spark power.
The operation of the traction and overheating sensors is checked by direct closure of their contacts. Place jumpers on each device in turn, including the water on the faucet.If a flame appears, replace the faulty sensor.
If the flame in the column lights up properly together with the appearance of a water draw, and after 5-10 seconds it goes out, then the reasons may be as follows:
the ionization sensor does not work (does not detect the ignition of the fuel);
there is no draft in the chimney, which is why the corresponding sensor overheats and opens the electrical circuit;
the maximum heating is set at a low water consumption, which is why its temperature quickly reaches 90 ° C and the overheating sensor is triggered.
The last 2 malfunctions do not depend on the water heater and are eliminated by the user on an individual basis. Sometimes the damping effect is created by a diaphragm that is too stretched: at the first moment after water is supplied, it moves the stem, and when the pressure in the pipe is normalized, it releases again.
The flame sensor fails for three reasons:
The electrode is covered with a thick layer of soot and requires cleaning.
The "nose" of the device is bent down from prolonged exposure to temperature and needs to be slightly bent up, as shown in the video.
The device is out of order and needs to be replaced.
The opposite situation also happens: the DHW tap is closed, and the burner continues to work. Here there is a jamming of the stem, which is eliminated by disassembling and cleaning the water-gas block.
There are two reasons for this phenomenon: clogging of the burner nozzles and deposits in the heat exchanger tubes. In the first case, a change in the blue color of the flame to yellow or reddish is noticeable, the gas burner device begins to smoke. To eliminate it, it is advisable to call the gas service master, but if necessary, you can handle it yourself:
Shut off the gas supply.
Dismantle the burner by unscrewing the compression nut on the gas line and 4 screws not shown below.
Purge the assembly in an accessible way to remove dust, and then wash with a mild soapy solution.
Dry the device and re-assemble the column in reverse order.
If the burner operates properly, but the water does not heat up, then the heat exchanger must be flushed. The factory - the manufacturer provides for a simplified dismantling of the element: drain the water from the column, unscrew the two connecting nuts on the pipes (shown in the photo with green arrows) and 2 fastening screws from above. After that, immerse the heat exchanger in a bucket with citric acid solution (100 grams per 1 liter of water) and wait until it corrodes the scale. After thoroughly rinsing and drying, reinstall the element.
Advice. When reassembling the heat exchanger, it is advisable to change the rubber gaskets inside the union nuts.
This is not to say that it is unrealistic or unacceptable to repair the Neva gas water heater yourself. You can really cope with the common malfunctions described above on your own, and without any special tools. It should be remembered that the water heater belongs to gas-powered equipment that requires a careful and thorough approach.
Heating systems for country and country houses. Boilers, gas water heaters, water heaters - Repair, service, operation. Recommendations for assembly and installation.
Operations for the repair of the Neva 4511 gas water heater (VPG-18 water heater), associated with the disassembly of its gas or water communications, must be performed only after it is completely turned off (the taps on the water and gas lines in front of the device must be closed).
When disassembling and assembling water and gas communications, it is recommended to install new seals. After replacing units and parts, it is necessary to reassemble in the reverse order.
Figure A. Water heater diagram VPG-18
1 - Frame, 2 - Heat exchanger, 3 - Gas burner (10 sections), 4 - Electronic control unit, 5 - Water-gas unit, 6 - Pipe (from the water unit to the heat exchanger), 7 - Pipe (hot water outlet), 8 - Facing, 9 - Cover, 10 - Handle, 11 - Battery compartment, 12 - Flame detector, 13 - Display, 14 - Thermal relay, 15 - Candle, 16 - Water temperature sensor, 17 - Bar, 18 - Burner nozzle, 19 - Adapter, 20 - Bracket, 21 - Microswitch (water flow sensor), 22 - O-ring, 23 - Bracket, 24 - Bar, 25 - Clamp, 26 - Wire,27 - Solenoid valve, 28 - Gasket (D19 × d10 × 2), 29 - Gasket (D28 × d17 × 1.5), 30 - Ring (D15 × 2.5), 31 - Water unit
Removing the lining of the gas column Neva 4511
- Remove the handles 10 by pulling them towards you.
- Unscrew the two self-tapping screws at the bottom of the product that fasten the cladding 8 to the frame bracket 1.
- Disconnect the wires connecting the display with the electronic control unit and with the water temperature sensor.
- Pull the lower part of the casing towards you, slide it up and remove it from the device.
Burner replacement
- Disconnect the wires from the spark plug 12 and from the flame detector 15.
- Unscrew the union nut of the burner manifold 3.
- Unscrew the two screws securing the burner 3 to the brackets of the frame 1 and remove the burner.
- Check the tightness of the joints that were disassembled on the operating device by soaping.
- Check the operation of the new burner while the machine is running.
Replacing the heat exchanger of the gas column Neva 4511
- Unscrew the two self-tapping screws securing the strip 17 to the gas venting device and remove it.
- Unscrew the two union nuts from the connections of the heat exchanger 2 and remove it.
- Check the tightness of the joints, which were disassembled on the working device by the method of soaping for gas and visual inspection for water.
Replacing the battery compartment
- Disconnect the two wires from the battery compartment 11.
- Open the battery compartment cover.
- Unscrew the two screws securing the battery compartment to the bracket and remove it.
- Install a new battery compartment.
Figure B. Water-gas water heater unit Neva VPG-18 disassembled
21 - Microswitch (water flow sensor), 27 - Solenoid valve, 31 - Water unit, 32 - Spring, 33 - Gas valve, 34 - Bushing, 35 - Spring, 36 - Gasket, 37 - Ring D2.8 × 1.9 , 38 - Ring D8.8 × 1.9, 39 - Ring 17.4 × 2.65, 40 - Ring D27.5 × 2.65, 41 - Ring D29.5 × 1.8
Replacement of a water-gas unit (UVG)
- Disconnect the three wires from the solenoid valve 27.
- Disconnect two wires from microswitch 21.
- Disconnect the gas and water supply to the device.
- Disconnect the adapter 19 from the water-gas unit 5.
- Unscrew the four screws securing the water-gas unit to the frame bracket 1 and remove the water-gas unit.
- Install a new water-gas unit.
- After installing and connecting the water-gas unit, check the gas and water connections for leaks. Water and gas leaks are not allowed.
- Check the operation of the device with a new water-gas unit.
Replacing the valve of the electromagnetic unit of the water-gas
- Disconnect the three wires from the solenoid valve 27 of the water-gas unit 5.
- Unscrew the two screws securing the solenoid valve and remove it.
- Install a new solenoid valve.
- Check the functionality of the device with a new solenoid valve.
Rice. B. Assembly of a water geyser Neva 4511
42 - Venturi connection, 43 - Water flow regulator, 44 - Filter, 45 - Ring D7.8 × 2, 46 - Ring D11 × 1.5, 47 - Ring D11.4 × d7.8, 48 - Ring D16.5 × 2.2, 49 - Ring D20.5 × 1.8, 50 - Membrane with a plate (water unit repair kit).
Replacement of the unit of water UVG
- Disconnect the water supply to the water-gas unit.
- Disconnect the nut of the cold water outlet pipe to the heat exchanger 2 from the water unit 31.
- Unscrew the two screws securing the water unit 31 to the body of the water-gas unit.
- Unscrew the two screws securing the water unit 31 to the frame bracket 1 and remove it.
- Install a new water unit.
- Check the connections for leaks. Water leakage is not allowed.
- Check the operation of the device with a new water unit.
Replacing the thermostat (water overheating sensor)
- Disconnect the two wires from the thermostat 14 on the hot water outlet pipe 7.
- Unscrew the two screws securing the thermal relay with clamp 25 and remove it.
- Install a new thermostat.
- Check the operation of the device with a new thermostat.
Replacing the water temperature sensor
- Disconnect the two wires from the temperature display 13.
- Unscrew the water temperature sensor 16 from the hot water outlet pipe 7.
- Check the operation of the Neva 4511 gas water heater with a new sensor by comparing the water temperature readings on the display and the thermometer readings when measuring the hot water temperature at the outlet of the apparatus.
Replacing the cold water supply pipe to the heat exchanger
- Unscrew the union nut from the connection of the water unit.
- Unscrew the union nut from the pipe connection 6 of the heat exchanger 2 and remove the pipe together with the gaskets 28.
- Install a new pipe with new gaskets.
- Check the operation of the device. Water leakage is not allowed.
Replacing the hot water outlet pipe from the heat exchanger
- Disconnect the wires and remove the thermal relay 14 by unscrewing the clamp screws 25.
- Unscrew the hot water temperature sensor 16.
- Unscrew the two screws securing the hot water outlet pipe union 7 to the bracket on the rear wall of the frame 1.
- Unscrew the pipe nut 7 from the heat exchanger pipe connection 2 and remove the pipe.
- Check the operation of the device. Water leakage is not allowed.
Replacing the thermal relay (draft sensor)
- Disconnect the wires from the thermal relay 14.
- Remove bracket 23 from thermal relay 14 from GOU by pressing the latch on the bracket.
- Unscrew the two screws securing the thermostat 14 to the bracket 23 and remove the thermostat.
- Install a new thermostat.
- Check the functionality of the device with a new thermostat.
Replacing the electronic control unit of the geyser Neva 4511
- Disconnect all external connecting wires and connectors of the electronic control unit 4.
- Unscrew the two screws securing the electronic control unit to the bracket on the rear wall of the frame 1 and remove it.
- Install a new electronic control unit.
- Check the operation of the VPG-18 water heater with a new electronic unit.
Replacing a spark plug or flame detector
- Disconnect the wires from the spark plug 12 and from the flame detector 15.
- Unscrew the two screws securing the rail 24 to the bracket 20 and remove it.
- Replace spark plug or flame detector.
- Check the operation of the device with a new spark plug or new flame detector.
Replacing the microswitch (water flow sensor)
- Disconnect two wires from microswitch 21.
- Unscrew the two screws securing the microswitch to the UVG and remove it.
- Install a new microswitch.
Video (click to play).
- Check the operation of the device with a new microswitch.