Repair of electric ignition of a gas water heater with your own hands

In detail: do-it-yourself repair of electric ignition of a gas water heater from a real master for the site my.housecope.com.

The gas column ignition unit in working order prevents emergencies, ensures that the main burner is triggered when the hot water tap is opened and the flame dies out after it is closed. There are several types of columns, classified according to the type of ignition, differing in the internal structure and principle of operation.

The main difference between piezoelectric ignition and flow-through boilers with manual ignition is that the pilot burner is ignited by means of a piezoelectric element built into the structure. Despite the popularity of automatic dispensers, domestic and foreign manufacturers still produce gas flowing water heaters with piezo ignition and a constantly operating ignition burner.

The principle of operation is in many ways similar to that used in columns, where the burner is ignited from matches. There are common structural elements, the same breakdowns are encountered.

The design contains a permanently working ignition wick. To turn on the column, you must light the igniter. For ignition, a piezoelectric element is present in the structure, consisting of a power button connected to a spark electrode connected to the burner device. When the button is pressed, a spark is produced, hitting the burner, igniting the gas.

The principle of operation of a piezoelectric element is associated with the conversion of mechanical and kinetic energy into electrical energy. When pressed, a spark is generated strong enough to ignite the burner. Piezo ignition for a gas column often fails. After 3-4 years, you will need to change the unit and adjust it.

Video (click to play).

Symptoms of malfunction: weak spark, ignition after a large number of keystrokes on the element (normally it works with 1-2 clicks).

First, you should try to repair the piezo ignition. It happens that a malfunction is caused by breakdowns in the current-transmitting cable. Disconnect the speaker case to see the cause of the problem. After that, they press the piezo ignition button several times and watch where the spark is directed.

There is a gas spring in the feed pipe of the ignition burner. An additional function is to receive a spark from a piezo. The spring should be bent towards the electrode.

If the changes did not help, there is no spark, when changing the location of the electrodes, the situation does not change, the piezoelectric element of the gas column should be replaced. The key can be easily removed. Depending on the model, the housing is secured by a lock nut or several bolts. The wire from the electrode is folded back by removing the terminal. Works with certain skills take 10-15 minutes of time.

Present in fully automatic boilers. The principle of operation of a continuous gas water heater with electric ignition eliminates the need for a constantly burning wick. The main burner ignites immediately. The source of electricity is a 220 W household network, batteries or a built-in hydrogenerator.

Automatic electronic ignition of the geyser occurs when the hot water supply tap is opened. After closing the DHW point, the burner goes out on its own.

The device of the electronic unit for the ignition of gas water heaters is used in fully automatic water heaters. In the factory configuration, batteries are used as batteries.

Electronic ignition of a gas water heater works as follows:

  • the rod in the water reducer has special legs connected to the electric ignition;
  • when DHW is turned on, the membrane presses on the stem, opens the gas valve and at the same time gives a signal to generate a spark;
  • after ignition of the flame, the battery-powered spark generation unit is switched off.

Battery power has one major drawback. Replacement of elements is required every six months. If you wish, you can install an adapter and connect the speaker to a household power supply through it. This solution will eliminate the need for constant and frequent battery changes.