Possible malfunctions and how to repair them

It is important to remember that any actions aimed at repairing a water heater must be carried out on an apparatus disconnected from the water, gas and electricity supply.

The appliance does not ignite, but a spark is present

1. No gas supply. It needs to be restored by opening the valve.
2. Weak water supply to the system. It is necessary to contact the utilities and file a complaint about insufficient water pressure. If this does not solve the problem, you will need to install an additional pump that normalizes the water supply pressure.
3. Although the water is supplied to the system with good pressure, the pressure at the outlet drops dramatically. It is necessary to inspect all filters installed in the system. Most likely they are hammered. Also, similar problems can be caused by a heat exchanger overgrown with scale. To repair it, it is necessary to dismantle it and wash it using special acidic agents. If you cannot buy reagents, you can use citric acid.

The Vektor Lux gas water heater does not start, there is no spark

1. It is necessary to check in which mode the relay that controls the water pressure is installed. Perhaps it is set to a minimum. Switch it to maximum.
2. The batteries may need to be replaced. Buy and install a new one.

Column jsd20 w turns off, some time after starting work

1. Very poor traction. The sensor is triggered. You can verify the presence of traction using a burning match. If there is a problem with the chimney, you need to clean it yourself, or call a specialist from the service department.
2. Leak at the junction of the gas outlet pipe. It is necessary to check and, if necessary, restore the tightness by laying heat-resistant sealing material at the joints.
3. The water heating control sensor has been triggered. Use the handle on the left to lower the temperature.

Video (click to play).

The water temperature does not heat up to the desired level, while the gas supply is maximum

1. The heat exchanger is heavily clogged. It is required to rinse it. To clean the outer surface, it is necessary to dismantle and place the heat exchanger in hot soapy water for half an hour. To improve the result, it is allowed to use a brush. For internal flushing with a heat exchanger, it is necessary to soak it for one hour in warm water with acidic solutions added to it. Next, you need to thoroughly rinse with running water and install in place.
2. Weak gas pressure. It is necessary to write a statement to gas workers.
3. If during the operation of the device, after a while the fire goes out, then most likely the membrane is clogged or damaged. For repairs, it is necessary to disassemble the water-gas unit, remove the damaged elements, install new ones. It is desirable that the membrane is made of silicone.
4. If the flame turns yellow instead of blue, it is likely that a lot of dust and soot has accumulated inside the burner. To fix this problem, you need to clean it. Before that, you need to dismantle, and use a brush to clean the dust and dirt. The use of a soap solution is allowed. Thoroughly flush all channels and inner sections. After the performed actions, you can put everything back.

Reasons for the lack of ignition

There can be many options why the Vektor Lux Eco gas water heater does not ignite: There is no spark. The spark is present, but the ignition does not go on. Water supply pressure too high. Other reasons.These and other possible breakdowns, and repair options will be considered on the example of the jsd20, jsd 20 w model with automatic ignition.

Gas water heater Vector does not ignite. The spark is missing

This malfunction can be caused by several reasons:

1. No cravings. Most likely the airway is clogged. It is checked with a lighted match or a sheet of paper. In the presence of draft, the flame will deflect towards the duct or go out. If this is the problem, you need to clean the chimney.

2. The pressure of the water supplied to the unit is too low for correct operation. It is necessary to check the filters, they may be clogged. The main filter is located in front of the water heater block. It can be removed easily, just unscrew the nuts. If the filter is heavily contaminated with lime deposits, you will most likely have to buy and install a new one. The second reason may be too little pressure in
supply line. You can try contacting the service provider, or install an additional pump. You can also try buying another column that can handle this pressure. You also need to check the mixer, perhaps the reason for the blockage in it. The flow of water in the heat exchanger may be impaired. To eliminate the cause, it is necessary to dismantle the
water tap and gas valve. Carry out descaling using special chemicals, or ordinary citric acid.

3. Breakage of the membrane. It is located inside the water tank. To get it, you need to remove the cover. After gaining access to the membrane, it is necessary to carefully inspect. If it works correctly, it should be properly stretched, there should be no holes or deformation. Better when a membrane made of silicone is installed. When installing, at the beginning, screws are placed opposite each other, and then all the rest are attached.

4. Inoperative batteries. The most common reason for this breakdown. Battery life does not depend on what is written in the instructions. They change as they fail.

5. The contacts of the battery pack are oxidized. Their cleaning is required.

6. The handle is not installed correctly. The handle of the water regulator is moved to the extreme left position. For a spark to appear on the Vektor jsd 20 w column, you need to switch the handle to the far right.

7. Oil seal leaks inside the device. If, when removing the cover, you can see that water is dripping from the valve, the problem is in the gland. Its replacement is required. It is also necessary to install a new microswitch.

8. The stem of the machine has lost its mobility or has oxidized. To fix it, the switches are dismantled, allowing the pieces to be released. If it turns sour, cleaning and lubrication is required.

9. Broken microswitch. Determined by short-circuiting it. In the event of a breakdown, replacement is required.

10. Damage to the electrical circuit between the microswitch and the control unit. Make sure that all contacts and wires are in good condition and not oxidized. Clean or replace if necessary.

11. Malfunction of the solenoid valve. Replacement required.

12. Breakdown of the control unit. Replacement required.

Instantaneous water heater Vector does not turn on, despite the fact that there is a spark

1. There is no gas, as the tap is closed. To fix the problem, you need to restore the gas supply.

2. Insufficient water pressure. To solve this problem, it is necessary to install an additional pump.

3. The water comes out of the device with insufficient pressure. The problem most often lies in the fact that all filters that are installed at the inlet of the device are dirty, or the mixing valve is clogged. Use a special brush to clean them. Replacement is required if there is a very large scale layer. To increase the service life of the filters, it is necessary to periodically inspect and wash them.

4. Limescale has formed inside the heat exchanger. It is necessary to wash it both inside and outside.For external washing, it is necessary to dismantle the heat exchanger and place it in a container that is much larger than it (it is important that the heat exchanger is completely covered with water). If during installation it turns out that the nuts cannot be unscrewed, since they are clogged with scale, you can use special components. The inside of the heat exchanger is flushed with citric acid solution. It is prepared like this: 100 g of powder must be dissolved in one liter of water. The heat exchanger is kept in the solution for 15 minutes. Then you need to rinse everything thoroughly. If the rinsing quality is poor, part of the scale, not flushed out the system, can block the passage in the heat exchanger. Do not use hydrochloric acid as it can decompose the metal.

5. Batteries installed too low. Install the batteries according to the instructions.

6. The burner is heavily soiled. A very common reason why the burner does not light up. It is not recommended to clean this part yourself. It is possible to remove soot from the inside of the burner nozzles using a thin copper wire or using a wire brush. After that, you need to make sure that there is no gas leak anywhere using a solution of soap applied to the joints of the joints. It is recommended to clean the burner regularly.

The Vektor Lux Eco gas water heater ignites, but after a while it stops working

There are several reasons for this behavior of a gas burner. Below are some of them.

1. Poor draft as there is no indoor air circulation. This usually happens with doors and windows tightly closed. Accordingly, the protective relay overheats and the overheating protection sensor is triggered. To eliminate the problem, it is recommended to open a window or window, providing a supply of fresh air. This is necessary, since the device burns a lot of air during its operation.

2. Too short activation time of the ignition button. It must be held for more than 20 seconds.

3. Breakage of the sensor for the removal of combustion products. It is necessary to measure the resistance on it, normally it should show to infinity. If not, replacement is required.

4. Cold water is supplied under too much pressure, and hot water is too low. This happens if, while using hot water, a cold tap is opened at the same time. To eliminate it, it is important that the hot water supply is adjusted so that hot water does not need to be diluted. Dilution of hot water is a violation of the operating instructions.

5. Water supply pressure too high. This problem most often occurs on Lux Eco gas water heaters, which are structurally designed to work with low pressure. If the water supply pressure is higher than the norm, the membrane of the water unit sags in the column, and thereby moves the stem, blocking the gas supply. To eliminate it, you need to adjust the gas supply, or reduce the water pressure.

6. The temperature sensor is triggered. Its main function is to protect against overheating. The device works for some time, but gradually turns off. If you then try to turn it on, it will not work. It is possible to start the device only after 25 minutes, but it goes out very quickly again. In such a situation, the sensor is too sensitive. It needs to be replaced.

7. Poor contact between thermocouple and solenoid valve. After making sure that the thermocouple is in working order, it is necessary to check and, if necessary, clean the contacts and the automation unit. And also the igniter itself, and the device for the formation of an electric spark. The design of the electrode assumes that the spark hits a comb welded to the edge of the gas burner at a distance of about 12 mm from the inlet.
If the Vector instantaneous gas water heater is set to operate at low water pressure, gas is supplied to the burner in small portions.As a result, a slight reverse thrust is almost always formed, and part of the gas is pulled away from the spark. To solve this problem, it is necessary to slightly move the electrode away from the comb. Position it so that the spark goes through the center of the burner. After carrying out these manipulations, the device will always be kindled, its work will become more constant and soft.

8. Holes have formed between the gas outlet pipe, the connecting branch pipes of the outlet device, the chimney and individual sections of the gas outlet pipe. This can be determined by looking closely at the system. For further work, it is necessary to close these holes with a special self-adhesive heat-resistant tape, but it is possible to use other materials, the main thing is that they are heat-resistant.

Instantaneous water heater Vector starts up after a while

This problem has several options for malfunctions, and, accordingly, several options for solutions.

1. The internal structures of the unit are dirty. Requires cleaning, paying particular attention to the nozzles and jet.

2. If cleaning did not help, it is not necessary to check the following items: electronic ignition unit, draft sensor, microswitch and solenoid valve. The problem is in which of these nodes.

3. If, when trying to start the unit, a crackling sound is heard, but the spark does not appear, then most likely the problem is in the microswitch. This can be determined by measuring the resistance on it. For diagnostics, it is necessary to remove the cover. To do this, pull both handles towards you and remove them. Next, it is important to unscrew the two screws located at the bottom of the device. Pull the lower part of the casing towards you, and lifting it, remove it from the pins. There is a microswitch under the cover in the very center. When a request for hot water comes in, the switch button should be released, since the special rod will come out of its place. If this does not happen, it should be pushed with a screwdriver and lubricated. After that, the device should ignite. If this does not help, a new microswitch must be installed.

4. If there is a spark, a click is heard, but the device does not ignite, the solenoid valve is broken. It is not being repaired. It is required to install a new one.

5. If you do not hear clicks and crackles, there is no spark, and the microswitch is working properly, then most likely the problem is in the electronic ignition unit. And it is very difficult to mount it, therefore it is recommended to buy and install a new one.

Image - DIY gas water heater repair vector

There are two complete sets of geysers Vector: JSD 20-W and Lux ​​Eco. The difference between the two is pretty minor.

Consumers note many positive aspects of Vector gas water heaters. The first is their cost. Water heaters under the specified brand are classified as relatively cheap equipment.

Image - DIY gas water heater repair vector

Secondly, buyers are attracted by the compact size and stylish design of Vector geysers, thanks to which they will perfectly fit into any interior.

Thirdly, the presence of a digital display, ignition in automatic mode and a copper heat exchanger greatly facilitate the control of gas equipment.

Fourth, the latest models of Vector columns are equipped with a temperature control system. The main criterion in this case is the season. It is also necessary to note the protection against overheating, the smoke exhaust system, ease of installation and power.

The main components of the Vector column include:

  • gas outlet device;
  • heat exchanger;
  • gas burner;
  • safety valve and overheating sensor;
  • water and gas unit.

Image - DIY gas water heater repair vector

This design is considered to be quite simple. Automatic ignition is switched on with a rotary valve. After opening it, the safety valve starts to gradually feed gas into the burner.

After the gas goes through all the stages of combustion, a certain amount of energy is released. It is designed to quickly heat up the liquid. This process occurs during the passage of water through the heat exchanger.By the way, the chimney is not always an obligatory addition to the Vector gas water heaters.

The equipment is capable of operating on both liquefied and natural gas. This circumstance is necessarily prescribed in the operating instructions.

For those who wish to purchase a Vector gas water heater, there is a useful bonus. It consists in the availability of services such as maintenance. In the event of a water heater breakdown, its repair will be carried out by a qualified technician as soon as possible. This will be facilitated by the absence of difficulties with the purchase of spare parts, the price of which is quite reasonable.

Problems with the Vector gas column can be as follows:

Independent repairs should only take place with similar experience. If it is not there, you should definitely call a specialist, and not try to fix everything yourself. Such recklessness is fraught with an explosion or spontaneous combustion. Image - DIY gas water heater repair vector

According to experts, the likelihood of the above problems arises due to the poor quality of the parts that make up the water heater, the lack of automatic maintenance of the required temperature regime, insufficient thickness of the walls of the heat exchanger and the power of the apparatus.

By the way, self-installation of a gas water heater is considered the basis for refusing to provide warranty repairs. The warranty period for Vector equipment is usually 12 months.

Image - DIY gas water heater repair vector

For a longer and more efficient use of the gas column, you must follow the instructions for its operation. It describes the procedure for turning on the unit, protecting it from freezing and cleaning. When using this equipment, it is necessary to take into account the external conditions, for example, if the water is hard, then the gas water heater must be cleaned at least once every 6 months. It is advisable to heat water no more than +60 degrees Celsius, since in this case there will be much less scale.

Malfunctions in Vector gas columns and methods of their elimination should be determined only by specialists. The procedure for diagnosing a water heater can be viewed in the video.

The most popular models of gas water heaters are the Chinese product - "gas column Vector". The orders of this product are controlled by customers from Russia.

Testing and quality control of gas water heaters is carried out at the factory. All this is done by qualified specialists.

Gas water heater "Vector" is a popular model among consumers in the Russian market. But the reviews about the gas column "Vector" are contradictory.

The Chinese product is very well thought out in the security system. The craftsmen took into account all the details of the work of the gas column. The safety system prevents the column from burning without water supply, an automatic shutdown is triggered here when the column overheats, or if water boils.

It was also provided for automatic shutdown of the device in the absence of chimney draft. The geyser "Vector jsd20 w" was equipped with a built-in automatic electric ignition. There are also many more positive aspects when using this product.

If you look at the Lux Eco vector gas water heater model, then such models are equipped with a clock on the displays that give information about the temperature of the water in the tank. This is a very handy feature. And the installation of a gas water heater also does not require exorbitant knowledge.

"Vector Lux" has good power, which can easily provide several points of water intake, such as in the kitchen and bath. And this is all important. It should be noted that this product is easy to manage.

Gas water heater Vector in a private house

An important point is the price of repairing the Vector gas column. You can also purchase the unit at any heating appliance store at an affordable price in any color option.Many consumers liked the "winter-summer" function, but many users have an opinion that this mode is no different from each other. The control unit of the geyser Vector is convenient and bright. The stores selling the Vector Lux gas water heater always have spare parts for it, as well as good service.

A qualified technician will always explain and find the reason for the breakdown of this product. The prices for spare parts and cleaning of Vector gas water heaters are below average, which allows for repairs, and this will not cost much.
to the menu ↑

When using the device, the most frequent malfunctions of the Vector gas column are weak batteries, which provide automatic ignition - they should be changed frequently.

In this case, you need to use expensive high-quality batteries. Also, the disadvantage is that the protection system is configured too tightly in the device. Stable water pressure and good water flow are required for normal operation.

There are drawbacks in changing the outlet water temperature, and this happens if there are large pressure drops. In these cases, automatic temperature setting is used, and the Vector gas column does not have it.

It looks like a gas water heater Vektor

It will be difficult to manually set these settings. The most common breakdowns are as follows:

  • gas column Vector does not light up;
  • no spark on the gas column Vector.

These are the most common breakdowns. Also, breakdowns are less common, like a cracked heat exchanger tube. The device of the Vector gas column is not convenient, since when removing the heat exchange unit to clean the unit, you will encounter many difficulties.

Attention! If your Vector gas water heater does not light up, then you need to immediately call the wizard, since fixing a breakdown in such models with your own hands is a great danger (explosion, fire).

It should be noted that not every store has a complete list of spare parts for the unit. There are also cases that even "GORGAZ" refused to repair this unit, since the employees are not familiar with the device of the column.

They demanded a Vector gas water heater scheme, but the consumer often did not find it. A significant drawback of this unit is that, with prolonged use, the process of turning it on often breaks down. Explosion may occur due to untimely ignition of the gas. At the same time, consumers experience fear when they turn on the column. If your Vector gas water heater does not turn on, then it is better to call a qualified technician.

If you listen to numerous reviews, you can come to the conclusion that the Vector gas water heater is not operated as easily as it seems at first glance. Such a device requires understanding several basic principles of this unit. Even experienced specialists have the question of how to disassemble the Vector gas column?
to the menu ↑

The design of the unit is very simple. In principle, she is no different from her fellows. Consists of:

  • Main burner;
  • Ignition;
  • Heat exchanger.

The Vector Lux gas water heater consists of a painted metal frame, which is very similar to an ordinary kitchen cabinet. The above elements are located inside this frame. Two pipes emerge from the bottom of the frame. One for gas supply, the other for water.

Gas column device Vektor

The principle of operation of the unit is also simple. All models have automatic ignition type. This means that the column turns on after you turn the jib crane.

After you open the rotary valve, a valve is triggered in the column system, which slowly passes gas into the pilot burner, and then into the main burner. After that, the gas burns out and the column releases heat and energy to quickly heat up cold water. Cold water flows through a spiral tap (heat exchanger) and hot water is supplied to the tap.It should be noted that the Vector gas water heater can work without a chimney, and this affects the low cost of installation.
to the menu ↑