Let's say right away that repairing a gas water heater, like any other gas equipment, is a matter exclusively for professionals. But, although repairing speakers with your own hands is not allowed, knowledge is not superfluous. The ability to determine on your own what exactly has broken down, how this breakdown threatens, and what the repair can be will not interfere with anyone. What breakdowns of gas water heaters are there, and what "symptoms" are they accompanied by?
At first glance, repairs may seem difficult
To begin with, before getting acquainted with the basics of troubleshooting, it is not out of place to find out how the gas water heater is arranged, the repair will largely depend on the device. We will not delve into the intricacies of the device of many speaker models, we will limit ourselves only to acquaintance with the general principles.
Centralized hot water supply appeared relatively recently by historical standards. The issue of heating water at home was solved in various ways, but the most common one we had was a storage solid fuel heater - the so-called titanium. Titanium was fired with coal, less often with wood or fuel oil. The water in the boiler had to be warmed up in advance. So taking a bath had to spend at least an hour. Of course, using such a device was very inconvenient. The problem of fast heating of water was solved in gas water heaters.
Gas water heater device
The work of the geyser consists in heating tap water with gas from the city main. To speed up the heating process, a heat exchanger serves, in which the water flow is distributed through a system of thin tubes located directly above the gas burner. Due to this, it is possible to heat the water quickly enough, right in the process of use, there is no need to pre-accumulate the heated water in the tank.
Video (click to play).
This is the fundamental device of the gas water heater, all the rest of the filling serves to ignite the gas, regulate the heating of the water, and also ensure safety.
The main burner is ignited:
From the igniter. The constantly burning igniter, in turn, is turned on by piezo ignition (automatic or manual from a button) or manually ignited from a match. Unless, of course, you are lucky enough to get ownership of such a rarity.
Piezo ignition without igniter.
Electronic ignition. By its structure, electronic ignition is similar to the ignition of a car.
Security systems are:
Mechanical. Almost any column, even stuffed with electronics, is equipped with a simple device - a mechanical connection between a membrane in a water intake device and a valve in a gas pipe. The gas valve only opens when the water pressure pushes against the diaphragm with sufficient force. The principle is simple: no water - no gas is supplied to the burner, turn on the water - the burner turns on.
VIDEO
The column may not work for many reasons. Now we will tell you about the most common ones.
There may be several reasons why the gas column does not light up. First of all, make sure the pilot is on. If the igniter does not work, call the gasman from the public service, he will replace or clean the igniter jet.
In columns with electronic ignition, if ignition has not occurred, the gas supply is cut off by a valve, which the user is informed about by the corresponding indicator. Study the instructions (which you should have studied before turning on the column for the first time), perhaps the problem can be solved with your own hands by simply replacing the battery. Otherwise, contact the manufacturer.
Another reason that the gas column does not ignite may be the lack of draft in the ventilation shaft. You can check the draft by holding a sheet of paper or a lighted match to the ventilation grill. If there is no draft, you can eliminate the blockage of the ventilation well with your own hands, or by contacting the utilities.
Warm water will not give a lighted column
Another reason for burner failure is deterioration of the water diaphragm. The membrane deforms over time from constant loads, the burner switching device loses sensitivity when water is supplied and does not work. Unfortunately, nothing can be done about this, even in the columns of serious Western manufacturers, the membranes have to be changed every 5-7 years.
Try to open the water tap to the maximum, if the column is turned on at maximum pressure, then it is the membrane that will have to be replaced. It is also necessary to check the filter that is equipped with the water intake of the column. Insufficient water pressure to open the gas valve may be due to a clogged filter. The water filter does not belong to gas equipment, and you can replace it yourself.
VIDEO
Finally, the column may not light up due to improper operation of the bimetallic sensors. They will be discussed below.
If the column ignites, but goes out, the culprit is most likely a bimetallic temperature sensor, designed to protect the column from overheating. A malfunction usually has two manifestations:
The burner lights up, the column works normally for a while, after which it goes out and does not work for some time - attempts to ignite the results do not give results. After 15-20 minutes, the column can be turned on again, the burner lights up, and then again, after about the same period of time, it goes out again. This happens due to the "innate" increased sensitivity of the sensor.
It also happens that the column goes out at the most inopportune moment
In principle, this is a warranty case, but the fact is that the problem is seasonal in nature and arises during the heat of summer or winter, when the windows in the kitchen are constantly closed. In both cases, the air temperature is elevated and the column is not cooled properly. It may happen that the problem will manifest itself when the warranty period expires. Alas, in this case, the repair will have to be done at your own expense.
Disconnections of the column are chaotic, the device sometimes does not light up at all. Such behavior of the heater may indicate deterioration of the insulation of the sensor conductor. A short to the body occurs, causing the safety valve to operate. It is useless to call the gasman - the problem is not in the gas part, you should also not try to fix it with your own hands. For repairs, it is better to contact the manufacturer of this model or to the service center.
If gas is supplied, it means that the water pressure in the water intake is normal, the problem is in the blockage of the heat exchanger with scale. One of the reasons may be "idle" combustion of the igniter for a long time. The igniter has enough time to heat the heat exchanger, causing active evaporation of the remaining water. The formed scale is not washed out due to the lack of water flow and until the next turn-on of the column has time to "grab", the result - the column does not work. Repair consists in cleaning or replacing the heat exchanger.
Scale-clogged heat exchanger Reduce water pressure
Possible reasons are as follows:
The gas pressure is too high, the burner ignites too actively, as a result of which the flame breaks out.
The gas pressure is too weak, air gets inside the burner, which is accompanied by a microexplosion.
The burner needs cleaning and adjustment. In principle, nothing complicated, but you do not need to take on this work with your own hands, the repair of the gas water heater should be carried out by a specialist.
Insufficient heating of water can be associated with a low power of the column.Do not turn on the hot tap in the bathtub, sink and kitchen at the same time, or buy a more powerful unit.
An incorrectly selected column will not have time to heat the water
Another possible cause could be a clogged burner, as indicated by a yellow flame. Call a gasman, a specialist will solve this problem in an hour.
This is already serious and threatens with the most dire consequences. Turn off the column immediately, turn off the gas supply valve, provide constant ventilation in the room, call the emergency service (104) and wait for the arrival of the brigade.
In conclusion, once again I would like to remind you of security. Do not attempt to disassemble, clean or repair gas equipment yourself. This is a job for qualified professionals only.
To understand in detail how to repair a gas water heater with your own hands, consider the most common breakdowns, their causes and remedies.
All repair work must be performed with the gas valve closed (read how to repair the Oasis gas water heater in this article), even if you do not plan to disassemble the gas part. There is a chance that you accidentally unscrew the wrong nut and gas will start to come out.
The heat exchanger consists of a casing and pipes, into which cold water enters and heats up there. In any case, over time, a small layer of scale appears inside. The main reasons for its occurrence are the high hardness of the water and the operation of the water heater at temperatures above 80 degrees.
It is possible to determine that the pipes of the column are clogged with scale by the fact that cold water flows from the tap actively, and hot water from the column in a thin stream.
The column can be repaired without removing the heat exchanger. The gas is turned off and the water valve is closed. It is necessary to remove the cover from the device and drain the water. To do this, unscrew the union nut from the water inlet to the water heater and turn on the faucet located below everything in the system, usually a faucet in the bathroom. Termaxi geysers have a special tap for draining water from the system. In this case, it is easier to drain the water into a substituted container.
After that, the nuts at the inlet and outlet of the heat exchanger are unscrewed and a special anti-scale liquid is poured into it through a hose, which can be bought at hardware stores. You can also use a vinegar or citric acid solution.
The column is left in this form for several hours. Then everything is connected back and the water valve is turned on. You need to slowly turn on the hot water tap. A dirty liquid should pour out. If after this the head has increased, then the heat exchanger pipes are cleaned. If necessary, you can repeat the entire cleaning procedure several times.
In order to avoid this breakdown, you need to use a water heater at temperatures of the order of 40-50 degrees. You can also install a filter at the inlet, which will purify the water from salts, which form scale.
The heat exchanger radiator consists of pipes and metal plates closely spaced to each other. The plates are in direct contact with the flame, so over time, soot collects on them.
You can determine that the problem is in this by the following indicators:
Flame yellow.
The fire does not tend upward, but to the side, heating the case.
When operating at full power, the water heats up slightly.
Soot is pouring out from under the column.
In order to clean it, you need to remove the heat exchanger. For this, the casing is removed, and all the elements that hold it are unscrewed. During parsing, cover the burner with a rag so that soot does not get into it.
After removal, the unit rushes to the bathroom and washes there. It is best to leave it in a container with high sides for a few hours to allow the soot to deteriorate. Further, the space between the fins of the heat exchanger is cleaned under running water using a long-bristled brush and detergents. At the end, dry and install in the reverse order.
If water begins to drip from the column, the reason may be that fistulas have formed on the copper pipes. In order to find the place of leakage, you need to carefully inspect the heat exchanger with the water turned off. Some fistulas are easy to find, you will see how water comes out of these places. Small holes can be seen by green spots and rust all around.
There are three ways to eliminate the leak:
Fit a clamp with a rubber gasket. If space allows, and the pipe does not fit snugly against the casing, the simplest, fastest and most effective is to install a metal clamp with a rubber gasket. Despite its simplicity, this method allows you to eliminate the leak without damaging the structure.
Solder the fistula. Having previously cleaned and degreased, the leak is covered with a flux. After that, using a powerful soldering iron or a torch with a gas cylinder, the fistula is soldered. In this case, it is necessary to ensure that the solder covers the desired section of the pipe with a layer of 1-2 mm.
After the end of the soldering, water is run into the water heater to check it. It is advisable to additionally clean and solder all areas of a greenish tint. Perhaps, after a while, new fistulas will appear there.
Also, leakage can form due to the fact that the gaskets are worn out. If water flows out of the pipe joints, you should simply replace the gaskets there with new ones.
a - good traction, b - no traction, c - reverse
The fact that the pull is not strong enough can be seen in the following attributes:
The column lights up and then goes out. This triggers the flue gas sensor.
The water heater works only when the window is open. If the window is closed, then the flame goes out after some time.
To check if the problem is really weak draft, you should bring a hot match to the chimney. The flame on it should deviate to the side. It is also noticeable in the direction of the flame in the igniter.
There may be several reasons for poor traction:
The chimney is blocked. It may have accumulated a large amount of soot or a foreign object. In this case, you need to clean it. If you live in an apartment building, then the chimney shaft can be clogged much higher. In this case, you should contact the utilities.
Powerful hood. If an active hood is switched on in parallel in the kitchen, then the exhaust gases can be drawn into it, instead of going straight up. Then the exhaust gas sensor will work and turn off the column. You should turn off the hood fan while the column is in operation, or change it to a less powerful one.
Insufficient height of the chimney. If the column works in your home, it is possible that the chimney is not high enough. Its end must rise at least 50 cm above the roof ridge.
The chimney is covered from above. Installation of satellite dishes over chimneys is prohibited. Also, umbrellas, weather vans and caps should not be set too low.
For prophylaxis, the chimney draft itself should be checked every three months.
The membrane is located in the water regulator. When water enters it, the membrane bends under pressure and presses on the stem, which is connected to the gas valve and opens the gas. Over time, the membrane can stretch or break. If the gas switching system breaks down, the water heater will either stop switching on completely, or the flame will be very weak.
New Chinese water-gas systems have been installed in the Neva Lux, Oasis and Termaxi dispensers. They are located horizontally, there is a gas unit on the left, a water unit on the right.
To replace the membrane, you need to remove the casing from the column and drain the water from it. To get to the membrane, you need to disconnect the water supply pipes with a 19 wrench. Then the entire water-gas system with the burner block is unscrewed and pulled out. And at the end, the four screws on the water regulator are unscrewed.
For replacement, you need to take a silicone membrane, it will last longer. Also on sale are repair kits that additionally contain gaskets and spare parts.It is important to correctly align the water regulator and diaphragm by-pass orifices, otherwise the unit will not turn on.
After replacing the membrane, the column is reassembled and tested.
Also, in addition to fundamental breakdowns, there are a number of problems that can be solved without much difficulty:
Clogged strainers. Since the water in the taps is hard with a high salt content, over time, simple strainers at the inlet to the column become clogged. They should be changed from time to time.
Weak water pressure. If the water pressure is not enough, the column simply will not turn on. You should check how the water flows from the cold tap. If the pressure is weak there, you should wait or call the utilities. You can find out where to call in the help desk or on informational announcements at the entrance. This can also be eliminated by adjusting the pressure regulator on the column itself. You need to put it on a lower pressure.
The batteries are empty. If you have automatic ignition from batteries, then they should be replaced (read how to do this in Neva gas water heaters here). It is sometimes difficult to tell when the batteries are running low because the spark continues to crackle but is not powerful enough to ignite the gas. Some speaker models have a battery indicator on the screen or a special light. In modern models, two batteries marked R are installed. You should take expensive alkaloid ones. Usually the cell with them is located at the bottom of the case.
The igniter is clogged. If you have a model with piezo ignition, then the igniter is located above the burner. Once a year, it should be cleaned of dust. The protective washer is removed and it is carefully pulled out in the upward direction. The toothbrush cleans its location on the device. The igniter itself is a tube, which is also carefully cleaned with a thin wire.
The electrical part of the device may be damaged. In this case, you should call specialists. Possible malfunctions of the Power gas water heater are described at the link: https://my.housecope.com/wp-content/uploads/ext/830/gaz-kolonki/firma/neispravnosti-gazovoj-kolonki-power.html.
Also, turbocharged columns (for example, Termaxi JSG 20R) and columns with a hydraulic turbine are distinguished by a complicated device. For their repair, it is also advisable to call specialists.
If you smell gas, then you should immediately turn off the column, close all gas valves, turn off electrical appliances, open a window and call the gas service.
Below, see 3 videos on repairing a Bosch gas water heater.
VIDEO
VIDEO
VIDEO
Any professional will tell you: "a gas water heater is a potentially dangerous equipment, so you can only entrust its maintenance and repair to a qualified specialist." However, the ability to understand which element is out of order and what it can lead to will definitely not hurt.
DIY geyser repair
In addition, you can deal with the elimination of some malfunctions that do not specifically affect gas equipment on your own. Read the description of typical breakdowns and recommendations for action in case of their detection.
Gas column device
Equipment can stop igniting for several reasons.
Gas column device
First of all, you must make sure that the igniter is working properly. If it does not light up, contact your gas service. A specialist will clean or replace the failed element. You cannot touch it yourself - it is dangerous.
Gas column device diagram
In modern units with electronic ignition, in the absence of ignition, gas ceases to be supplied - it is cut off by a valve. The user becomes aware of this through the corresponding indicator. In some situations, this problem can be solved by simply replacing the battery. Check this point in the instructions.If the manufacturer does not give such recommendations, it is better to immediately contact the gas service or a third-party repair service.
At one point, the column may not light up
Battery pack for igniting the column
The column will not light up if there is no ventilation draft. To check the level of traction, we bring a strip of paper to the ventilation grill. If the leaf does not change its position, or if it does not change it sufficiently, there are obvious problems with craving. In apartment buildings, utilities are engaged in cleaning ventilation wells - contact them. You can do this yourself with the help of a metal brush tied to a flexible wire (hose, etc.) of a suitable length, however, utilities usually do not approve of such unauthorized actions.
Burners often fail to fire due to diaphragm wear. This structural element deforms rather quickly, the burner starting mechanism becomes less sensitive and does not work when the water is turned on. Even in expensive heaters, membranes wear out in 5-8 years - unfortunately, nothing can be done about this.
Often burners do not fire due to diaphragm wear
To check, turn on the water to maximum. If the column turns on with a strong pressure, the problem is definitely in the membrane. Replacement of this element can be done on your own.
To do this, do the following:
unscrew the fastening nuts from the water unit (usually there are 2 of them);
unscrew the fastening screws, due to which the water unit is held in the gas unit (usually 3 screws);
detach the halves of the assembly and you will see a rubber membrane. If it is not flat but noticeably deformed, replace it. To do this, buy a similar product from a specialized store. If possible, give preference to a silicone membrane - it will last much longer than its simple rubber counterpart.
At the same stage, you can check the condition of the water intake filter. If it is clogged, clean it or replace it with a new one. To clean, simply unscrew the nut from the water supply side, take out the mesh and rinse it or replace it with a new one, depending on the condition.
If the heater turns on but goes out, the problem in most situations is the bimetallic temperature sensor needed to protect the equipment from overheating. Also, due to malfunctions of this element, the heater may not turn on at all.
This problem has 2 main development scenarios.
According to the first scenario, the burner lights up properly, the equipment functions for some time without any complaints, and then goes out and for some time does not show any signs of life - attempts to ignite the heater do not lead to anything. Usually, after 20-30 minutes, the equipment turns on again and history repeats itself. This is due to the excessive sensitivity of the sensor. As a rule, it is "congenital", i.e. this is a factory defect. It is extremely difficult to do something on your own. It is better to immediately contact the manufacturer's service for warranty repairs.
According to the second scenario, the column may turn off randomly, and sometimes not turn on at all. The reason usually lies in the wear of the insulating material of the conductor of the bimetallic sensor. There is a banal short circuit to the case, as a result of which the safety valve is triggered, and the column begins to behave abnormally.
Contact the service center for warranty repair
It makes no sense to turn to gas workers - the defect is clearly not a "gas" one. You also don't need to try to get rid of the breakdown yourself - you can only break the unit. Contact the service center for warranty repairs.
Water comes out with a weak pressure
Most often this happens due to clogging of the column heat exchanger with scale. Prolonged “idle” ignitions of the igniter are usually the cause of clogging.The device heats up the heat exchanger to a temperature sufficient to cause the remaining moisture to evaporate.
There is no water flow, scale is not washed out of the heat exchanger, until the next turn on of the equipment, it sets, as a result of which the column ceases to function normally. Cleaning the heat exchanger usually saves. In advanced cases, it has to be changed.
For replacement, it is better to immediately contact the professionals, but you can handle the cleaning on your own. Prepare screwdrivers, rubber hose, open-end wrenches and paranite gaskets. Purchase a descaling mixture from a hardware store. Usually it is called that - antiscale. A more budgetary option is rinsing with vinegar essence. Work in this order.
First step. Remove the fittings and the casing from the heater one after the other.
Second step. Turn off the inlet water and open a hot water tap, preferably as close as possible from the column.
Step three. Unscrew the water supply pipe from the heat exchanger and then move it to the side. After unscrewing the nut, the column heat exchanger will begin to release water. In total, about 1 liter of it will be drained.
Fourth step. Place a hose of a suitable diameter on the inlet of the heat exchanger and lift it just above the heater. Insert an ordinary funnel into the fixed hose and start slowly pouring in the prepared solution in a thin stream (instructions for preparation are given on the package). There is no need to rush. If you pour it too quickly, the antikipine will simply push it back out, and you are unlikely to like it.
Flushing the gas column heat exchanger
Leave the cleaning agent in the heat exchanger of the heater for 2-3 hours (usually the required time is indicated on the packaging).
Place a suitable container under the water tap and carefully re-feed the heater. Observe what comes out of the hose. Was there a lot of slurry coming out, and then the head returned to normal? Things are good. Otherwise, flushing will have to be repeated. Usually, the need for re-rinsing arises only when using vinegar essence. Anti-scale in most situations copes with the first time.
In such a situation, it is better to immediately contact a professional. He will perform the adjustment, which is extremely difficult to make without knowledge of the matter, and the column will start working normally.
You can find out the reasons for the appearance of such a malfunction for general development. There are two main reasons:
the gas comes under too much pressure. The heater ignites too actively, which leads to the breakdown of the fire;
the gas flow is too low. Air enters the heater burner, resulting in a microexplosion, which is interpreted by human hearing as cotton.
The column does not heat up the water sufficiently
This usually happens due to the insufficient power of the gas column. The user begins to demand more from the equipment than it can do.
There are two options for solving the problem:
we stop abusing and do not open hot taps at the same time at all points of the water intake;
buying a more powerful speaker.
Also, inadequate heating of the liquid can occur due to the clogging of the burner. Look at the color of the fire. Under normal conditions, it is bluish. If the flame turns yellow, contact the gas industry. Such repairs can only be entrusted to a professional, tk. this is already a "gas" breakdown.
The problem is more than serious. Don't even think about any hand-made repairs. Turn off the heater, turn off the gas cock, ensure that there is adequate ventilation at all times, and call the gas service immediately. The arriving team will assess the problem and take appropriate action.
Now you know the main malfunctions of the gas column, and you know how to behave when they appear. The main thing is to remember about safety.There is no need to try to fix breakdowns for which you do not have enough qualifications - this can lead to irreparable consequences.
VIDEO
Despite the widest range of electrical heating appliances on the market, the gas water heater is still one of the most popular means of heating a house and providing it with hot water. This is a fairly economical option, since it allows you to simultaneously provide several drainage points in the house. Another advantage of gas water heaters can be considered the fact that they allow you to use hot water, practically unlimited, without any restrictions.
The geyser device looks like this.
Water flow regulator.
Chimney connection.
Power control.
Heat exchanger.
Water node.
Exhaust hood.
Switch.
Rear panel.
Diaphragm gas valve.
Ignition.
Gas unit.
Perhaps you will also be interested in an article about gas heating boilers, read more about them here
Two pipes are connected to the gas column. The first of them is designed for gas supply, the second - for cold water supply. In addition, a pair of burners is located at the bottom, one auxiliary and one main.
Important! The device of the gas column can be different, depending on the method of ignition - it (ignition) can be electronic, manual and using a piezoelectric element.
Such devices are designed to provide domestic and industrial facilities with hot water. The essence of their work is quite simple: cold water from the pipeline enters the column heat exchanger, where it is heated by burners (they are located under the heat exchanger). As you know, fire needs oxygen, therefore, so that the burners do not go out, the column is connected to the ventilation system of the house / apartment. The exhaust gas is eliminated by means of a special chimney, which is combined exclusively with a gas water heater.
Read about what to look for when choosing a water heater here
All the described types of columns function somewhat differently.
So, if the device is turned on manually, that is, the gas has to be ignited with matches, the burner will ignite from the fact that you turn the fuel supply valve. Although it is worth noting that such designs have become outdated a long time ago. Modern designs are equipped with either an electronic ignition or a piezoelectric element.
New models are activated at the touch of a button located on the front panel of the device. Piezo ignition creates a spark that ignites the pilot. In the future, everything happens in automatic mode - the tap opens, the column lights up, hot water begins to flow.
If the gas water heater is fired up electronically, then it is perhaps the most reliable and durable device. The system is turned on by means of a pair of batteries supplying the charge necessary for the formation of a spark. No buttons, no matches, the only thing you need to do to turn it on is to turn on the tap. In most cases, batteries last a very long time because the energy required to charge is minimal.
How to calculate gas consumption for heating a house - read here
The use of gas water heaters, however, like any other equipment, is accompanied by malfunctions, frequent or rare. At the same time, there are such malfunctions that can only be eliminated by specialists who have the necessary knowledge and admission for this. But there are those that can be easily eliminated with your own hands, so we will consider them.
Video - sensor malfunction
VIDEO
VIDEO
The most "popular" type of failure is that it simply does not turn on. If it has an electronic type of ignition, then you can easily solve a similar problem - just check the batteries and, if necessary, replace them with new ones. Often, such troubles overtake the owners a year after the purchase, since the batteries last mainly so long.
Also, when using a gas water heater, it may happen that the water in it does not warm up, or it warms up, but not well enough. Often the cause of such problems is the water unit, or rather, its defect. As a result, the membrane stops responding to pressure changes in the water supply system. And if this membrane stops stretching under the pressure of water, then, as a result, the gas valve will not open, or it will open, but not completely. To solve this problem, you should at least in general terms know the device of the gas water heater, because the defect can be of several types.
If salt deposits have accumulated.
If the system is clogged.
If cracks have formed, etc.
To eliminate such a problem, you must first of all disconnect the column from the gas supply, then clean the water block and check the membrane.
If the internal elements of the device are covered with soot or dirt, then this can also lead to failure. To solve this problem, you must remove the outer casing of the device, then clean each of the elements using a vacuum cleaner.
The next sign that the gas column has stopped working correctly may be the burner decay immediately after switching on. This happens due to the fact that the ventilation channel is clogged. Modern models of gas water heaters are equipped in such a case with special sensors that will inform the owner if there is no traction. After that, immediately turn off the gas supply. Next, the chimney should be checked. For this, the plug is dismantled and everything that has accumulated there is removed.
Important! You can check the draft of the chimney in the old "old-fashioned" way: bring a lighted match to it. If the fire on the match deflects in the direction of the chimney, then everything is in order with it. If this did not happen, then he needs a complete cleaning.
It is for this reason that the gas water heater should be inspected annually - this is the only way it will work correctly.
We also advise you to familiarize yourself with the basic requirements.
Modern gas water heaters are small and compact, so they can be placed in almost any convenient place. Their service life depends largely on how correctly they are installed and used in the future.
As you know, the device of the gas water heater is such that it has to work with a rather dangerous fuel. For this reason, during installation, make sure that, God forbid, there is no gas leak. If you cannot, for one reason or another, take care of this, or, even worse, cannot eliminate all the leaks, then further operation will turn into a dangerous activity, which sooner or later can lead to an explosion.
For this reason, it is categorically not recommended to install a gas water heater with your own hands. It is better to have professionals who have all the necessary skills, experience, and the appropriate equipment to do this.
So, for installation, you need the following tools:
dowels;
magnet and salt filter;
drill;
the required number of taps;
pipeline;
chimney corrugation;
gas pipe;
Mayevsky valve;
actually, the column itself.
The device is installed only in the kitchen and only on the wall, which is made of refractory material. The distance from the column to the wall surface should be at least 2 centimeters, if it turns out more, then this is even better. An asbestos sheet should also be laid here, which must have a minimum thickness of 0.3 centimeters.
Important! The apartment / house must have a chimney that will remove the products of gas combustion. It will consist not only of vertical, but also of horizontal sections, and on them it should go at a slope (approximately 0.2 centimeters per each running meter).
So that the pipeline does not accidentally burst, the gas column should be installed only when the water is completely drained from the system.
But editing, as we have already said, is not the most important thing. It is also important that the device is used correctly, for which certain operating rules must be followed. If you do not do this, then even the most expensive and high-quality model will soon break down. So we want to prevent this from happening. Firstly, we must not heat the water to a temperature that would exceed 60 degrees. The fact is that too high a temperature will lead to the formation of salt scale on the walls of the heat exchanger. The result is more frequent cleaning or, even worse, replacement of the heat exchanger.
In addition, we can damage the structure of the heat exchanger by using too hard water. To avoid this, the water should be softened using special means, or a special filter should be installed in the system.
Finally, it is not recommended to dismantle and clean the gas water heater with your own hands, because, as we have already said about this, professionals should deal with this procedure. Doing this with your own hands is extremely dangerous.
If you decide to purchase a geyser device for yourself, then pay attention, first of all, to the power of the model you have chosen. It should be enough to provide all your family members with hot water. The power of almost all modern models fits into the range from 3 to 60 kilowatts.
Important! The more powerful the gas water heater, the more water it will be able to heat up within a certain period of time.
The average “cell of society”, consisting of four people, needs a device with an average capacity of 16-24 kilowatts. It is more than enough for the dishes to be washed and everyone was able to take a shower. Even if the device has a low power of 16 kilowatts, it will be able to give 10 liters of hot water, which is enough to be able to wash and wash dishes at the same time. Of course, if you can, then buy a column with a capacity of 24 kilowatts, since it can provide 24 liters of heated water.
In addition, it is advisable to take into account the water temperature that a specific model can provide. For its designation, the Latin letters DT are used. For example, if water is already supplied to the heat exchanger at a temperature of 12 degrees, then it will heat up to 24 in it. therefore, it can be used even without preliminary dilution.
Today there are models that are capable of heating water even up to 50 degrees. Their power, as well as the cost, is an order of magnitude higher than conventional models. For this reason, if several plumbing elements are simultaneously connected to the system at once, then it is better to purchase a more powerful column so that it can provide them all with hot water at the same time.
Also, when buying a gas water heater, see if it is equipped with safety sensors. They are of the following types:
overheating;
damping of the burner;
burning;
reduced pressure;
temperature;
sudden interruption of water supply.
And remember: gas water heaters are only allowed to be installed in the kitchen! Installation of a gas water heater in the bathroom is prohibited! Unless she (the bathroom) meets all existing requirements.
So, we have analyzed what a gas water heater is, what are its features, what malfunctions may arise during operation and how to fix them later. We only note that such devices are extremely economical, especially in light of the ever-increasing utility rates. And the last thing: do not forget that prophylaxis of the column's performance should be carried out annually.
I wrapped the microswitch, which is under the flow sensor rod, in plastic wrap and now it is not afraid of leakage.And my leakage is so small that I couldn't see the drop nirazu, and the dampness still limescale the microswitch button, so that it did not come out of it and did not turn on the electronics. The microswitch can be easily removed from the bracket with two small screws.
I have a problem with a Selena gas water heater. As soon as the lid in the battery compartment is closed, the gas immediately ignites even when the water is closed. To heat the water, I first open the tap with water, then close the battery compartment lid. To turn off the gas in the column, I open the battery compartment cover. I called the master, changed the microswitch, but it did not help. The foreman cannot determine the breakdown. Who knows how to fix it, leave a comment, please.
tell me why there is a very weak water pressure in a turbocharged selenium gas column
after the column lights up, after a few seconds, the piezoelectric element is triggered and it goes out
Cac saedeniti provodchi U menea sieli v siu provodcu crisi
amine column. lights up and the temperature rises to the maximum (70) and does not fall, the gas pressure is not regulated (gas at minimum). What could be? Thank you
put a new column RODA-20 A-6 started right away but after a minute it went out. after half a minute it caught fire by itself. and so until I typed in the bathroom, no matter what I did or did not regulate, it didn’t work. What could be? Thank you
column ross burns error her
As soon as the lid in the battery compartment is closed, the gas immediately ignites even when the water is closed. Tell me what to do, it's a piez.
what needs to be changed if the temperature is not regulated heats 27 no more.
Rod's gas water heater gets water on the batteries, what is the reason
what to do if you have to turn on the water both in the bathroom and in the kitchen so that the automatic column works is not very convenient
Video (click to play).
When water is supplied to the column, the lamp does not turn green. There is a spark that clicks, but the column does not ignite What could be the reason, not serviceability.