The unit of the two-chamber refrigerator Stinol RF 345A is assembled according to the classic single-compressor scheme. A cyclically operating cryogenic evaporator is installed in the refrigerating chamber, and a classic static evaporator without an automatic defrosting function in the freezer. The electrical wiring diagram of the refrigerator is also simple and reliable - nothing more.
L - Phase
N - Neutral
M - fan motor
SK - thermostat
SB (S) - push-button switch
CO - compressor
EL - lighting lamp
HLG - indicator lamp
The diagram conditionally shows:
The position of the contacts of the pushbutton switch SB (S) is when the door of the refrigerating chamber is open.
The position of the temperature-sensitive contact of the SK thermostat is when the shutdown temperature is reached.
1 - compressor
2 - discharge pipeline
3 - capacitor
4 - filter drier
5 - capillary tube
6 - evaporator of the refrigerating chamber
7 - freezer evaporator
8 - suction pipeline
It's no secret that STINOL refrigerators are widely used in Russia. High technical and consumer characteristics, as well as low price have made this brand truly popular. However, the experience of operating such refrigerators shows that after 5-7 years temperature regulators (or thermostats) fail in them. The most common reason for this is a violation of the tightness of the bellows (thermosensitive element in the regulator). The reason is that the service life of these devices, produced by the German company RANCO, is about 5 years. In this article, we will focus on troubleshooting the K series thermostats in Stinol-101/103 refrigerators, as well as the procedure for replacing them.
Video (click to play). |
Possible defects of refrigerators, in which a check is required, and, if necessary, replacement of temperature controllers
2. The compressor of the refrigerator runs continuously even when the temperature control knob is OFF. The temperature in the freezing and refrigerating chambers (MK and HC) is significantly below normal.
3. The temperature in the MC and HC is above normal even at the maximum position (extreme clockwise) of the temperature control knob.
Using the example of the "Stinol-103" refrigerator, we will consider the procedure for replacing the XK type K-59 thermostat (the type marking and pin numbers are printed on its body). The replacement steps are shown in Fig. 3-9.
Using an awl or a thin screwdriver, pry off the temperature control knobs and remove them (Fig. 3 shows the left knob).
The "Stinol-101" refrigerator has only one temperature control knob.
Then remove the decorative strip 2. The strip has 6 projections that hold it in the dashboard. Two protrusions are located on the sides of the lining and two (bottom and top) at a distance of 17 cm from its edges. Since the cover is made of a fragile material, be careful when removing it. Having removed the cover, unscrew the nuts 1 for fastening the temperature regulators (Fig. 4). Then, the hex screws securing the dashboard are unscrewed. It should be noted that when removing the panel, the last to unscrew the fastening screws of the door hinge plate 1 (Fig. 5). In this case, the door must be supported. After unscrewing all the screws, raise the panel and remove the door. Then, on the back of the refrigerator, the fastening screws are unscrewed and the top cover is removed.
Take out the thermostat from the dashboard (Fig. 6), having previously disconnected the contact connectors from it. In order not to confuse the connectors when
connecting a new regulator, they should be marked.
In HK, unscrew the plastic cover 1 (Fig. 7) and release the capillary tube 2. Remove the lighting unit 1 (Fig. 8), having previously unscrewed the screw recessed in its housing. Pull the capillary tube of the thermostat outward through hole 2.
Install and connect a new thermostat. When doing this, pay special attention not to damage the capillary tube. There is a section at the end of the tube where there is no insulation material. When installing the tube, make sure that this end is completely hidden under the decorative strip 1 (Fig. 7). To maintain the tightness of the HC, close the hole on the back of the refrigerator, formed during the installation / dismantling of the capillary tube, with plastic mass 1 (Fig. 9). Since the length of the capillary tube is much longer than necessary, it is carefully placed in the free cavities under the top cover of the refrigerator.
It is clear that it is impossible to check thermostats at home; this requires special equipment. However, there is a simple way to check these devices by eye. At room temperature, contacts 3 and 4 of the "K" series thermostats must be closed. If there are signs of malfunction 1 (see at the beginning of the article), close with a jumper its contact. 3 and 4. If the compressor then turns on, it can be concluded that the thermostat is defective and must be replaced.
It should be noted that the thermostats have adjustment screws. They are usually painted over and adjusting them without special equipment is not recommended.
The table shows the technical characteristics of the "K" series thermostats.
Stinol refrigerators are the brainchild of perestroika. Novolipetsk plant began production in 1993, in 1995 a line with an electronic control system was introduced. Later, in the same area, they organized the production of refrigerators of another Italian brand, Indesit, but spare parts for Stinol continue to be produced. This is important, the refrigerators have worked for more than 10 years, the units need to be replaced.
All devices have a standard metal case and an inner chamber. A heat-insulating layer of polyurethane foam is laid between them. There is also a capillary pipeline and a filter drier. The system is moisture and pollution dependent. Possible malfunctions of the Stinol refrigerator are often associated with this circumstance.
The number of compressors is 1 or 2. A vertical shaft is used. Static evaporators are in the form of tubes attached to the shelves. The Know Frost system is located behind the chambers, heat transfer is carried out by an air flow directed by a fan.
They characterize the normal operation of any Stinol refrigerator, the ratio of the temperature in the freezer, close to the back wall of the cabinet and the power consumption. To detect a malfunction of the Stinol 102 two-chamber refrigerator, it is necessary to examine it for corrosive wear and the integrity of the case. The tightness and strength of the fastening of the assemblies will prevent vibration, which means the destruction of the overall structures. For the 102 series with two compressors, a frequent malfunction is the failure of the TH1 and TH2 thermostats.
Malfunctions in the electrical circuit and automation in any models, including the Stinol RF 305A 008 refrigerator, are eliminated after troubleshooting - searching for the causes of equipment failure. RF 305A 008 is a single compressor model with two evaporators. A typical breakdown of the device is a refrigerant leak in the door heating circuit. The repair consists in laying a new circuit to replace the worn one.
It is known that part of the freon evaporates from the system during a year of operation. After many years of operation of the Stinol two-chamber refrigerator, a shortage of refrigerant will become a guaranteed malfunction. An excess of it is as harmful as a lack. If a fistula appears in copper pipes or in the evaporator, an oil stain is visible from the leak.
The Stinol 101 series of two-compartment refrigerators has one compressor for the cold cabinet and the freezer compartment. If the refrigerator does not turn on, there are possible reasons:
- malfunction in the wiring or lack of power in the network;
- open circuit of the fuse;
- the compressor does not work;
- low voltage in the network.
You can make sure that there is no voltage if the indicators do not turn on, the inner light does not light up when the refrigerator door is open.
If one of the cabinets of the Stinol 101 refrigerator does not work well, the reason is a malfunction:
- thermostat of one cabinet;
- lack of refrigerant;
- air leaks into the chamber;
- the quick freeze button is jammed (the refrigerator is freezing).
The freezer is located at the bottom, with a lack of freon, it maintains a minus temperature, it rises in the refrigerator.
A drip system for defrosting the refrigerator compartment is used, if the drain hole is clogged, water can collect. The freezer needs to be thawed regularly. With ice build-up, the temperature will begin to rise, and electricity consumption will increase.
Refrigerators Stinol 102 and 103 are similar in design, have 2 compressors, electronic control and drip defrost for a cold cabinet, the freezer is cleared of ice manually.
A typical reason for the malfunction of the Stinol 103 refrigerator after 5-7 years of operation is the exit from the standing thermostats TH1 and TH2. The manufacturer has put a 5-year resource in these nodes. Signs of a malfunction of the thermostat of a two-chamber refrigerator are:
- the compressor does not turn on at any position of the regulator, when it is turned to the "off" position there is no relay click;
- the motor is constantly running, with any switching on and off of the thermostat;
- the temperature in the chamber does not drop even at the maximum setting.
Replacing the thermostat in this case is the only way to restore camera operation.
Often the reason for the failure of one of the chambers of the Stinol refrigerator can be a compressor malfunction. If, after starting, the power unit turns off immediately, you need to check the condition of the motor winding, the starting relay. Eliminate the problem by replacing the motor compressor. After that, you will need to check the system for leaks and fill it with freon.
The model of the Stinol 104 KShT-305 (NF3304T) refrigerator is three-chamber, a drawer has been added to the refrigerator and upper freezer. Defrost No Frost is used only for the upper chamber. The cooling system has one compressor, independent evaporators for the chambers.
Typical refrigerator malfunctions include:
- Freon leakage from the unit circuit with accompanying signs - ice freezing in the upper corner of the refrigerator, temperature rise, non-stop compressor operation and cold condenser.
- Clogging of the capillary pipe of the refrigerator will let you know with similar signs with a freon leak, but the first knee of the condenser will be hot, the rest will be heated to room temperature. If the refrigerator is turned off in the first seconds, the temperature of the filter drier will drop.
- The filter drier is clogged - the symptoms are the same as if there is no refrigerant in the system - it does not pass.
- The compressor can run idle without liquefying the gas, the signs of this malfunction are an increase in temperature in the cold chamber, the residual resource may be enough for the freezer.
- Defective thermostat - the temperature does not hold in the chambers, the mode adjustment remains unaffected, the compressor works without stopping or does not turn on.
Determine the malfunction, carry out diagnostics, the master must use the devices, removing the decorative panels. You can change the light bulb yourself, clean the condensate drain hole or replace the seal on the door.
Refrigerator single-compressor, two-chamber with Know Frost for the freezer and a "crying" wall for the cold cabinet. The unit has a complex electrical circuit due to the use of two defrosting systems.
Diagnostics of malfunctions of the Stinol 107L refrigerator and creation of conditions for their elimination. The temperature in the refrigerator depends on the thermodynamic balance of the system that contains the components of the dual refrigerant system. The balance will change if it happens:
- Freon leak from the refrigeration unit.
- Clogged capillary piping of the refrigeration unit is a problem for all refrigerators of this brand.
- Clogged filter drier.
- Loss of compressor motor performance.
Typically, the hot coolant circuit around the door is made of rusting steel. Over the years, the problem manifests itself as a freon leak, a new circuit is created during repairs. Rinse the capillary tubes, determine the functionality of the assemblies and carry out repairs by specialists.
In the Know Frost system, a malfunction or an open in the evaporator defrost circuit, fan defect may occur. Incorrect timer operation and clogging of the drain hole can lead to freezing of surfaces and a violation of the temperature regime in the chambers. Defects are found and corrected by the master.
The reason for the incorrect operation of the Styrene 107L refrigerator may be the failure of the thermostats. This is one of the most common faults. Sensor failure accompanies and is similar in signs to the absence of freon, faulty heating element Nou Frost, compressor malfunction. You can preliminarily determine the malfunction of the temperature sensor yourself, the device does not respond to commands, there is no click when setting the "off" mode.
We offer you to watch a video about malfunctions and their elimination in Stinol 107L refrigerators.
The model of Stinol 110 refrigerators with an overhead freezer compartment turned out to be the most reliable of the entire line. One compressor circulates the refrigerant through two evaporators, the thermostat is an electromechanical timer, providing the mode and turning on the heater between cycles.
A common cause of malfunction in the Stinol 110 refrigerator, after many years of operation, the craftsmen determine the clogging of the capillary tubes. As a result, the temperature in the refrigerator compartment is high. A characteristic feature is that the unit turns off spontaneously, it has to be turned on forcibly. For the same reason, a "fur coat" can form. A specialist can fix the problem by eliminating the plug.
Failure of the thermostat is the main cause of equipment failure. This is the reason why the constant alarm on the control panel can be explained. The lamp is on because the temperature in one of the chambers is not low enough. A defective thermostat could be the cause. As a consequence, the compressor cycle changes.
Refrigerators Stinol 110 are venerable age, the last one was released in 2005. Therefore, temperature incontinence may be dependent on the seal, it must be washed off with boiling water or replaced - elasticity and tightness are lost. If there are traces of rust around the seal, the circuit will soon need to be replaced due to the leakage of freon through microcracks in the tubes.
Refrigerators of the domestic brand Stinol with Italian origin are reliable equipment of the European level with excellent characteristics. Users noted such distinctive features of these household appliances as high-quality assembly, reliability, durability and democratic price. Despite the fact that the devices of this brand are no longer produced, Stinol units are still operating in many Russian families. But even with careful operation, over time, various malfunctions arise in the Stinol refrigerator. In this review, we will consider what difficulties the owners of different models of these kitchen units face.
Refrigerators of this brand consist of a metal cabinet of a standard rectangular shape with a built-in inner chamber. The freezer is made of durable polystyrene. Between the two blocks is filled with polyurethane foam, which is a powerful thermal insulation material. The capillary pipeline plays the role of throttling device... Thanks to this part, the refrigerator becomes sensitive to high humidity and dirt.
Depending on the line of the model range, there are 1-2 compressors installed in the equipment, which have a vertical axis of rotation. The part is located in the lower block of the cabinet. The device is a steel tube coil fixed in metal plates.
Exists two types of evaporator:
- Static device. It is located on the shelves.
- NoFrost system. It is located in a special compartment.
To find out the possible cause of the malfunction, it is necessary to carefully examine the unit for the operating condition of the elements:
- check the main nodes for corrosion of parts, deformation, mechanical damage to components, violation of protective coatings;
- examine the apparatus for tightness, strength of fastening of parts and automation devices;
- check 3 functional parameters of the device: temperature in the freezer and near the back wall of the cabinet, power consumption.
The entire model line of refrigeration units is distinguished by reliability, functionality and high build quality. However, they, like the kitchen appliances of other brands, are not immune to various breakdowns. Let's consider typical malfunctions typical for the Stinol line.
If the cabinet is defective, a thin layer of frost will build up on the static evaporator. As a result, a significant amount of liquid accumulates in the condensate container.
The defects of this condition of the refrigerator are explained violation of the tightness of the chamber due to:
- rupture or loose fit of the seal;
- deformation of the structure of the refrigeration unit;
- the presence of gaps between the rubber door seals and the surfaces of the freezer cabinet.
Possible malfunctions with sealing rubber restored with a hair dryer for drying and styling hair with a power of 1-1.5 kW. To do this, warm up the rubber seal in the place of contact with a hot stream. Then stretch it so that the shape of the part changes. After manipulation, the door must be closed. The refrigerator can be used after the seal has cooled down. If the protective layer is torn, it must be replaced.
Loose seal
Very frequent breakdowns occur with automation devices and electrical circuit components. These include:
- faulty starting or thermal relay;
- breakdowns of the compressor, fan and other components;
- reducing the insulation resistance of the electrical circuit;
- malfunction of the thermal fuse or defrost heater in equipment with the Nou Frost system;
- defect of the freezer, timer;
- breakdown of the evaporator pan heater;
- clogging of the drainage system with small particles.
Troubleshooting automation in the Stinol refrigerator consists in identifying the defective element, repairing, and if it is impossible to repair the breakdown, replacing the part with a new spare part.
If the amount of refrigerant is overestimated when filling the device, then the temperature in the freezer is less than -18 0 С, the refrigerating chamber is cold, the return pipe is covered with condensate or a layer of frost. To normalize the working process of the device, after a two-hour run-in adjust the dose of freon.
If the filling dosage, on the contrary, is underestimated, the refrigerator is warm and the temperature is reduced by more than -25 0 C. At the same time, frost may partially form on the back wall. As in the previous case, it is necessary to dose the lack of refrigerant to the norm.
If happened freon leak, oily spots appear in these places. The elimination of this problem consists in filling the unit with freon or in replacing the assembly component with a new part.
Warning! Freon vapor is a poisonous gas, so it is taken from the refrigerator to special refrigerators. After any work with the refrigerant, the room is ventilated for at least 15 minutes.
There are several typical breakdowns of Stinol units, which manifest themselves according to certain signs. In the table, we will consider the main problems with refrigerators of this brand, and how they manifest themselves:
breakage of the compressor windings;
the thermostat or start-up relay does not function;
open circuit of the thermal fuse;
jamming of the timer in defrost mode;
there was a violation of contacts in the connection of the electrical circuit due to oxidation
the bimetallic plate of the protective relay or the coil of the starting relay does not work
the rubber of the seal has lost its elasticity and shape;
the compressor has reduced performance;
the capillary line or filter drier is clogged;
the integrity of electrical circuits is broken
thermostat knob not adjusted
there was a depressurization of the system
clogging of the discharge tube with small particles
Consider the most common malfunctions of some models
- Two-chamber refrigerating device Stinol 102. The device has two compressors with a unique defrosting system for the NoFrost freezer. The front panel is equipped with two thermostats. A feature of the model is the circulation of air between the freezer and the fins of the evaporator due to the electric fan. Frequent breakdowns of equipment include a malfunction of a thermostat (in the TH1 or TH2 circuit). To make sure that the part is defective, it is necessary to remove the wires from the contacts numbered 3, 4 and short them with a jumper. If, after manipulation, the compressor starts up, there is a breakdown in the relay. It may be that the equipment does not cool when the compressor is running and the condenser is cold. In this case, there may be a freon leak.
The temperature regulator often fails. This is due to the fact that the thermostat of the German company Ranko, which were installed in a refrigerator, have a small working resource - about 5-6 years. If the temperature regulator in the refrigerator is not working, the compressor will not start. To exclude other breakdowns, it is necessary to check the serviceability of this part.
At home, it is difficult to check whether a device is working or not. However, there are 2 ways to determine the working state.
- Regulator contacts numbers 3 and 4 (in the diagram of the 103rd model they are designated as TH 1 or TH 2) must be closed. This maintains the integrity of the electrical circuit and the supply of mains voltage to the compressor input (in CO 1 or CO 2). It is necessary to determine whether the supply voltage goes to the regulator contacts. If it is not there, then the integrity of the entire circuit from the electrical outlet is checked, if there is, the power is turned off and the contacts are called. In case of breakage, the part must be replaced.
- Can also be shorted with a jumper thermostat input contacts... If the compressor works, then the regulator is defective. Otherwise, the failure did not happen to him. The malfunction is also determined by ear: when the thermostat switch is mechanically turned, a click occurs. If it is not there, then the probability of a part malfunction is high.
Any malfunctions of a refrigeration unit, whose service life is more than 10-15 years, requires a thorough examination by a specialist. Repair of Stinol refrigerators most often consists in replacing a worn out part. If you buy high-quality original spare parts and have experience in electrical work, you can replace the spare part yourself. If breakdowns occur too often, you should think about buying a more modern version of the refrigeration appliance.
Two-chamber Stinol 110L with No Frost and drip system. The signal light on the top panel next to the thermostat is on, but the refrigerator itself does not respond, it worked properly, please help.
If the warning indicator is on, this means that the temperature in one of the chambers is insufficient, the malfunction may be in the leakage of freon from the system or in the breakdown of the thermostat.
I have a Stinol 205 refrigerator. What can be? The freezer is working, but it's warm in the cold room itself.
First, check if the door in the refrigerator compartment is tightly closed and in what condition the seal is. If the seal is damaged or the door is not tightly closed, then it is cold in such hot weather. the camera does not work well. In your case, the following malfunctions may be: Burned out motor-compressor for models with 2 compressors; The thermostat (thermostat) of the refrigerating chamber is faulty; The temperature setting is incorrect. For units with thermostats (mechanical control), the norm is that the regulators are set in a position between
divisions 3 and 4.
Refrigerator Stinol-110 1995. After replacing the compressor, thermostat, dryer filter, replacing the freon, the cold-to works for three days. In the refrigerator compartment, the temperature is normal, but in the freezer the arrow is exactly in the middle (between red and blue), and the food is not frozen (chilled). Behind the tube leading to the compressor, it is all covered in ice. The master says that he poured more freon and it is necessary to bleed a little, and everything will be restored. I played it off a little (5 seconds) four times during the day. I'm afraid to play off the whole thing. There is less frost on the tube, but the temperature in the freezer has not dropped yet. Can I wait a little longer or is there another problem?
If the “return” (back tube) freezes, it is as if ice is clogging up, as if a lot of Freon has been flooded and it is necessary not only to bleed it off, but to refill it again. There is a lot of Freon and it freezes in the wrong place.
Please tell me the possible causes of breakdowns in the single-chamber refrigerator Stinol 205. Cold. the camera works very badly, but the freezer freezes well. At the same time, he is gaining a fur coat very quickly. On the back and on the side, and above and below, even the products are all covered in snow, and the freezer door itself is covered with ice. Defrosting didn't help. The light bulb is on. Although the motor rumbles loudly, it turns off and on as before.
If the cold does not work. camera, the following malfunctions are possible: Leakage of freon in the system. An indirect symptom of a leak is a loud compressor sound; Clogged capillary system; Failure of the thermostat.
How to defrost Stinol 116 EL two-compartment refrigerator?
Refrigerator Stinol 110 (with one compressor, 8-10 years old) in the upper part (2/3) of the HC a "fur coat" began to form, the freezing contour is clear. Repairs were made - replacement of the thermostat, removal of the circuit, refueling 134A. After the repair, the "fur coat" is also formed in the same place, the temperature in the HC remains +2 degrees at any position of the thermostat (from 1 to 5). Near the back wall -8. What could be the reason and how to fix all these malfunctions? The master is going to change the thermostat again.
The reason that, after the repair, a fur coat is formed again, may be in a defective relay. But, also, there may be a blockage in the capillary system. A clearer diagnosis from the master is needed. The blockage can only be determined by opening the system.
The Stinol 110 ER No Frost refrigerator works in 10-12 hours mode, then it turns off, then you have to turn it on forcibly through a timer. Why does the protection work?
If the unit turns off within 10-12 hours, then it is necessary to check it for clogging in the capillary system and freon leakage. The leak is checked by turning off the x-ka for a day. If after that both chambers do not work, then this is a freon leak.
I have a two-compartment refrigerator Stinol 116 EL with one motor-compressor stopped turning off. After replacing the thermostat, the unit turned off only after 14 hours of continuous operation (all drops froze in the cold chamber on the back wall). Did I buy a defective thermostat, or what else can I check? Tell me please.
It depends on which thermostat you have installed. If a thermostat for sub-zero temperatures is installed, then this may be the reason. If you installed a TAM-133 thermostat or an analogue, then in addition to the breakdown of the thermostat, you may also have a freon leak from the system. If the back wall is cold. the chamber is completely covered with frost and the compressor does not turn off, then, most likely, there are problems with the thermostat.
Hol-to stinol 116 er, two chambers. In the freezer minus 22, the refrigerator is warm. The compressor does not shut down at all. The light in it does not light (the spiral is intact), the light next to the temperature regulator also does not light. Help advice, what to make out?
Freon has leaked. This defect cannot be eliminated by itself. Regarding the light, the FOK switch is to blame.
Two-compartment refrigerator Stinol 205 E with one motor-compressor, the freezer is working, but the refrigerator is not.
Most likely, there was a leak of freon from the system. There is still enough freon for the freezer, but no longer for the refrigerator.
Refrigerator Stinol 110 L with one compressor, in the freezer the temperature is -20, -25, in the cold room +15, +20, it works constantly, without shutdown. 3 masters cannot find the cause of the malfunction. Freezer at the top.
Either a blockage in the capillary system, or a freon leak.
Kh-k Stinol 116 periodically begins to “growl”. If you hit it with your fist, it stops. Three-compartment refrigerator, year of manufacture around 2001 What to do? How long does he have to work? Can it be repaired or not worth touching?
If strong sounds periodically occur in the unit, then the reason may be that the compressor touches one of the tubes, or the evaporator inside twitches and touches the dried foam. This does not affect the operation of the unit in any way.
Refrigerator stinol 205 single-compressor. After turning on, it works for about 20 minutes, and the compressor does not turn on anymore. Replaced the thermostat - it did not help. Can a relay on the compressor be affected?
The relay, which is installed on the compressor, is protective. It breaks very rarely due to its simple design. Most likely, we are talking about either a malfunction of the compressor itself, or a failure of the thermostat.
What thermostat is needed for the Stinol 110l No Frost refrigerator? Ranco thermostat K59-L1275 or K59-L1955?
Refrigerator Stinol 116 er. He worked like a clock for more than 10 years. But for no reason, no reason, he stopped freezing. Turned off from the network. When you turn it on, the light comes on in it, it starts to buzz for 5-10 seconds and that's it, then there is silence. What about him?
If the unit turns on for 5-10 seconds and turns off, then the compressor motor has burned out.
How to replace the indicator light on Stinol 110?
Unscrew the self-tapping screw that secures the plafond that covers the hall lighting lamp. cameras. Unscrew the lamp and replace it.
The Stinol 205 refrigerator broke down. I turned it off for defrosting, then turned it on, but it doesn’t work, but the light is on.
In your case, possible malfunctions are a thermostat, a motor-compressor or a freon leak. Touch the back of the condenser (black grid), if it is hot, then there is a malfunction in the motor, if cold, then the thermostat may break down.
Possible problems
Fixing a Stinol refrigerator can be more time consuming than repairing other brands of refrigerator. One of the reasons is the No Frost cooling system, which is fundamentally different from other cooling systems.
Typical faults - Failure of the thermostat. Malfunctions in the No Frost system. Fridge sensor problems.Leakage of refrigerant as a result of leakage of the elements of the refrigerant circuit. Compressor damage. Wear of the rubber door seal. In freezers with a no frost system, there are cases when the defrost of the evaporator and the droplet burn out, less often the fan, timer or defrost fuse fail.
The repair may be caused by a temporary power outage. Reconnecting to the network is allowed no earlier than 4-5 minutes after disconnection. This time is required for condensation and refrigerant pressure drop. Otherwise, the starting load on the compressor motor is too high, which causes overheating of its windings. It is in this situation that engine failure is most likely. In such cases, it is necessary to automatically delay the switching on of the x-ka for about 5 minutes after the mains voltage is restored. The on-delay timer can perform this function.
It should be noted that for the prevention of repairs, the unit should be washed and cleaned 2-3 times a year with a cloth and warm water with a small amount of detergent. In no case should you use chemicals, as well as soap.
The upper chamber of Stinol 116 ceased to cool. What to do?
If the compressor is cold. the camera works without shutting down, but there is no cold, then most likely a refrigerant leak has occurred. In this case, it will be necessary to eliminate the leak, or install a new cold evaporator. chambers with subsequent replacement of the drying cartridge and charging the unit with refrigerant. If the compressor does not work, then most likely this is a malfunction of the thermostat, and it needs to be replaced.
What to do if frost develops on the back wall?
Possibly the door is not closed properly or there is a problem with the sealing rubber. When the compressor is running, it is normal for ice to form on the rear wall as long as there is enough cold in the cold. camera.
Refrigerator Stinol 205. After replacing the K-59 thermostat, it works without shutdown. In the freezer -30, and in the main chamber -0 degrees, this is at the minimum position of the thermostat knob.
Perhaps you have got a defective thermostat or it is not connected correctly.
A "fur coat" freezes on the back wall, the compressor does not turn off, it constantly works.
If the control is mechanical, the thermostat may be out of order. If electronic control, then most likely the temperature sensor or electronic control module is out of order, or there is a micro leak of refrigerant.
Stinol, in operation for 8 years, after defrosting in two days, was turned off only twice for 20 minutes. There is a fur coat on the back wall. What went wrong during defrosting?
It is possible that the camera was damaged during defrosting - this was the reason for the appearance of the fur coat. This may cause the temperature in the chamber to rise. Diagnostics required.
Some strange noise humming with hiss. Frozen in the upper compartment, the compressor is running, hot, but the noise does not stop. For about a month, he worked at number 4, turned off the regulator and after a while turned it on to number 1, there was no noise for about 10 minutes, then it reappeared. No frost system. Tell me the malfunction?
This problem may be related to a compressor malfunction. It is also possible for a micro-leakage of refrigerant with air to enter the cooling system, which causes extraneous noise in the operation of the unit.
The freezer runs almost continuously, the compressor turns off for only 10 minutes, the fan runs non-stop, the temperature inside is 24. What is the cause of the breakdown?
Most likely, the reason is a broken temperature sensor. The sensor needs to be replaced.
Please tell me if it is possible to replace the sealing gum on the lower door of the refrigerator in model 110 (size 57x110)?
The seal on the lower door of this model can be replaced.
What kind of malfunctions are there in these models?
There is no cold in the freezer. Refrigerant leakage may be one of the causes of the defect. Sometimes the problem is solved by replacing the thermostat. Rupture of the rubber seal.This is mechanical damage that appears when the door is used carelessly. To open the unit, you need to use the special handle, and not pull on the seal. If a rupture of the rubber appears, the seal should be replaced. Best of all, this work will be done by a specialist. There is very little cold in the freezer. Such a problem can be provoked by the chamber door not closed completely. The second possible explanation for the disadvantage is that the defrost system heaters have burned out. As a result, the snow “coat” does not thaw on the evaporator of the freezer. Sometimes the source of the deficiency is a clogged drainage system. This problem can be fixed fairly quickly.
It's no secret that STINOL refrigerators are widely used in Russia. High technical and consumer characteristics, as well as low price have made this brand truly popular. However, the experience of operating such refrigerators shows that after 5-7 years temperature regulators (or thermostats) fail in them. The most common reason for this is a violation of the tightness of the bellows (thermosensitive element in the regulator). The reason is that the service life of these devices, produced by the German company RANCO, is about 5 years. In this article, we will focus on troubleshooting the K series thermostats in Stinol-101/103 refrigerators, as well as the procedure for replacing them.
Possible defects of refrigerators, in which a check is required, and, if necessary, replacement of temperature controllers
2. The compressor of the refrigerator runs continuously even when the temperature control knob is OFF. The temperature in the freezing and refrigerating chambers (MK and HC) is significantly below normal.
3. The temperature in the MC and HC is above normal even at the maximum position (extreme clockwise) of the temperature control knob.
Using the example of the "Stinol-103" refrigerator, we will consider the procedure for replacing the XK type K-59 thermostat (the type marking and pin numbers are printed on its body). The replacement steps are shown in Fig. 3-9.
Using an awl or a thin screwdriver, pry off the temperature control knobs and remove them (Fig. 3 shows the left knob).
The "Stinol-101" refrigerator has only one temperature control knob.
Then remove the decorative strip 2. The strip has 6 projections that hold it in the dashboard. Two protrusions are located on the sides of the lining and two (bottom and top) at a distance of 17 cm from its edges. Since the cover is made of a fragile material, be careful when removing it. Having removed the cover, unscrew the nuts 1 for fastening the temperature regulators (Fig. 4). Then, the hex screws securing the dashboard are unscrewed. It should be noted that when removing the panel, the last to unscrew the fastening screws of the door hinge plate 1 (Fig. 5). In this case, the door must be supported. After unscrewing all the screws, raise the panel and remove the door. Then, on the back of the refrigerator, the fastening screws are unscrewed and the top cover is removed.
Take out the thermostat from the dashboard (Fig. 6), having previously disconnected the contact connectors from it. In order not to confuse the connectors when
connecting a new regulator, they should be marked.
In HK, unscrew the plastic cover 1 (Fig. 7) and release the capillary tube 2. Remove the lighting unit 1 (Fig. 8), having previously unscrewed the screw recessed in its housing. Pull the capillary tube of the thermostat outward through hole 2.
Install and connect a new thermostat. When doing this, pay special attention not to damage the capillary tube. There is a section at the end of the tube where there is no insulation material. When installing the tube, make sure that this end is completely hidden under the decorative strip 1 (Fig. 7). To maintain the tightness of the HC, close the hole on the back of the refrigerator, formed during the installation / dismantling of the capillary tube, with plastic mass 1 (Fig. 9).Since the length of the capillary tube is much longer than necessary, it is carefully placed in the free cavities under the top cover of the refrigerator.
It is clear that it is impossible to check thermostats at home; this requires special equipment. However, there is a simple way to check these devices "by eye". At room temperature, contacts 3 and 4 of the "K" series thermostats must be closed. If there are signs of malfunction 1 (see at the beginning of the article), close with a jumper its contact. 3 and 4. If the compressor then turns on, it can be concluded that the thermostat is defective and must be replaced.
It should be noted that the thermostats have adjustment screws. They are usually painted over and adjusting them without special equipment is not recommended.
Video (click to play). |
The table shows the technical characteristics of the "K" series thermostats.