In detail: do-it-yourself pump station impeller repair from a real master for the site my.housecope.com.
Do-it-yourself pump station repair: a list of possible faults and recommendations for their elimination
The further from the city we live, the less accessible services of all kinds of service companies and repair shops become.
Even if a specialist agrees to come to a remote settlement, he will probably have to wait long enough, and the payment for services will be higher than usual.
Therefore, it is extremely important for the owner of a private house to learn how to fix all kinds of breakdowns and accidents on his own, at least in the systems responsible for the life support of the house.
These include water supply, which today is often autonomous. How to repair a pumping station with your own hands will be described in this material.
To organize the work of an ordinary home water supply system, pumping stations (NS) with a hydraulic accumulator are used. The start and stop of the pump in such systems is carried out by means of a pressure switch. This device, adjusted to a certain pressure range in the pipe, closes the contact group at its minimum value and opens at its maximum value.
So that the pump does not turn on every time, as soon as one of the residents opens the tap (frequent switching on will shorten the life of the engine), a hydraulic accumulator is connected to the water supply. From the name it is clear that this reservoir is needed to create a supply of water, but it accumulates not only it.
NS may differ in various ways:
- Pump type: depending on the depth of the source, self-priming pumps (up to 8 m) and submersible are used. By the type of the pumping mechanism, most are of the centrifugal type, but among the submersible models, vibration ones are often found.
- Automation type: if the water flow is carried out exclusively in a continuous mode, for example, for irrigation, instead of a pressure switch, a flow sensor is installed on the HC. It turns on the pump with the beginning of the parsing of water (reacts to the movement of the medium in the pipe) and turns it off at the end. A hydraulic accumulator is not used in such an HC. Some HC models with flow sensors and without a storage device can also be used in ordinary household water supply. They are equipped with advanced automation, which is "able" to smoothly start / stop the pump motor and change its power. In the presence of such functions, frequent switching-ons become not terrible for the unit.
- Accumulator type.
Video (click to play). |
Pumping station in operation
In NS, two types of accumulators are used:
- balloon: water is pumped into a rubber "bulb";
- membrane: the volumes for air and water are separated by an elastic membrane.
Also, drives may differ in size. It should be borne in mind that the specification indicates the volume of the entire tank, and not the volume of the water tank in it.
Autonomous water supply in the house is an important component of a comfortable stay. Well or well - which is better for a country house and a summer residence? We will help you figure it out.You can familiarize yourself with the principle of operation of a dry closet for a summer residence here.
For tips on making a DIY vacuum press, read this publication.
Let's mentally walk through the NN and see what can cause disruptions in its work.
After turning off the unit, it is held by a check valve installed at the beginning of the water intake pipe.
In the event of prolonged shutdowns, the pump must be refilled.
If you are looking for a self-priming pump that does not need to be primed, choose a vortex unit.However, please note that it has a very low efficiency.
The lack of water in the suction line may be due to the following reasons:
- the water in the source dropped below the intake pipe;
- the work of the check valve is broken;
- cracks or gaps appeared in the line through which air entered it (a break in the water column occurred).
If the HC is equipped with a dry-running sensor, the pump will automatically shut down. Otherwise, it will work (until the overheating protection is triggered), but water will not flow.
The following troubles can happen to the main element of the neural network:
- impeller sticking: humming is heard, but the motor does not rotate;
- the capacitor is out of order: the signs are the same;
- due to wear of the casing and impeller, the pump cannot develop a pressure in the pipeline, at which the pressure switch is triggered: the unit does not turn off even at zero water flow;
- the engine is burnt out: the unit does not start, the smell of burnt insulation is heard.
Pump station with built-in ejector
Most often, the relay stops functioning for the following reasons:
- dirt has accumulated on the contacts, preventing the electrical connection: the pump has stopped turning on;
- there was a blockage of the connecting pipe: the relay stops responding to changes in pressure in the water supply;
- the springs have weakened, as a result of which the limits of the working pressure range have "floated".
Disassembled pressure switch
Signs of pipeline clogging depend on the installation location of the relay:
- the relay is located in the house next to the accumulator, that is, a plug formed somewhere between it and the pump: pumping water into the accumulator began to take longer than usual;
- the relay is installed next to the pump, that is, it is located between it and the plug: the unit operates in jerks (frequent on / off).
- depressurization of the case;
- rupture of the cylinder or membrane (in this case, when you press the spool, water will pour out of the tank);
- decrease in air pressure for natural reasons.
In all cases, the same symptom will be observed: the pump turns on every time the tap is opened.
To resume the work of the NS, it is necessary to do the following:
Self-repairing a check valve usually consists of removing any dirt or long-fiber inclusions that are preventing the valve from closing. For more complex breakdowns, the part is changed.
If cracks appear on the reinforced hose, through which the pump sucks in air, they must be sealed with reinforced tape to repair the pipelines.
A worn casing or impeller will have to be replaced.
There are models in which a stainless insert is installed. It is much cheaper to change it than the entire body.
Cleaning the contact group and the connecting pipe from dirt usually does not cause difficulties for users.By the way, it is best to remove plaque from contacts with a soft school eraser.
The adjustment of the relay is carried out by rotating two nuts screwed onto the rods with the springs put on them.
The value of the switch-on pressure (also called the lower one) depends on the compression ratio of the large spring, and the small one regulates the difference between it and the switch-off pressure (upper). Note, not the shutdown pressure itself, but the difference between the upper and lower pressures.
If the pump, due to wear, cannot develop a head sufficient to turn off, you need to wait until the pressure gauge needle stops at the maximum mark, and then manually disconnect the unit. Then, gradually loosen the small spring nut until the contacts click.
This will mean that the upper limit of the operating range of the relay corresponds to the maximum pressure that the pump can provide at the moment. For a reserve, the small spring can be loosened a little more. On the contrary, when tightening the nut, the range will increase.
Similar actions can be performed with a large spring, if, for example, it is weakened.
A crack in the accumulator housing is a good reason to contact the service department. But if its dimensions are not large, you can try to seal the hole with a compound of the "cold welding" type. If the membrane or cylinder ruptures, the part will definitely have to be changed.
Choosing NS, it is better to give preference to models with a bladder accumulator. Replacing the rubber "bulb" in such tanks, regardless of the model, is very easy. With regard to membrane accumulators, in many models of this type, only a service engineer can install a new membrane.
Old and new rubber membranes
Most often, to normalize the operation of the NS, you just need to pump air into the cavity of the accumulator. This is done using a conventional pump with a spool hose. In this case, the pressure should be monitored with a pressure gauge.
The change house, equipped with a bathroom and a shower, makes your stay at the dacha construction site comfortable. Two-room country cabins with toilet and shower - everything from materials to final finishing.The rules for the manufacture and installation of Zolotukhin's cages for keeping rabbits are described in this publication.
Its recommended value is indicated in the characteristics of the accumulator (usually 1.5 atm.), But it is not necessary to adhere to this value exactly. Ideally, the air pressure in the tank should be no more than 10% of the pump activation pressure.
Avoid using cheap Chinese pressure gauges in plastic cases, as these instruments give a large error.
Do-it-yourself pump station repair is one of the best options for getting out of a situation when some problems arise in it. Today the water supply equipment market is oversaturated with offers for every taste. Two water supply systems have positive reviews about reliability - the Marina pumping station and the Jileks station, the structure of which is identical.
Owners of their own water supply system on the territory of a private house or summer cottage often face various kinds of malfunctions. Basically, pumping stations contain the following elements:
- water pump;
- hydraulic accumulator;
- relay;
- pressure gauge.
The main task of the water pump is to take water from the right source. Surface pumps installed either in special rooms of the house or in caissons adapted for this are popular among consumers. The pump must have sufficient power to lift water from the well, move it to the house and lift it to the upper water-tipping point of the housing.
An important component is a hydraulic accumulator (storage tank) with a capacity of 20 liters or more. A hydraulic accumulator is a metal container, the task of which is to maintain constant pressure in the station pipelines. A successful model of a battery in the form of a metal balloon with a rubber membrane inside. The membrane stretches and goes back to its previous position, depending on whether the pumping station is running or not.
The relay turns on and off the pump, determining the need for its operation by the water level in the tank. The pressure gauge is designed to indicate the pressure level in the water supply system. The presented set of units and equipment of a water supply station can work as a single system, and each individual element can work on its own. On the market niche there are ready-made pumping stations in the form of a pumping device installed on a pressure accumulator. The single frame also contains an automatic control device.
The operation of the pumping station is carried out according to the following scheme: receiving power from the source, the suction pump begins to draw water, the water goes into the tank, filling it to a certain level, after which the pressure switch stops the suction device.When a person consumes water, the liquid level in the membrane tank drops, the pressure switch gives the command to implement the water intake process again.
Usually, when buying a pumping station, a warranty period is indicated. And what to do when the pump does not pump water after such a period has expired? There are certain approaches to performing work related to the failure of the station, allowing you to find the cause of the breakdown, and ways to repair the pumping station with your own hands. In many cases, this does not take as much time as it might seem at first glance.
The first step is to check the tightness of the pipes and the presence of water in the system. When there is no water, the cause could be a malfunction of the check valve located between the head of the well and the inlet pipe of the pumping station. This part stops working as a result of clogging of the valve with foreign objects. The unsuitability of the spring that controls the operation of this element is also being considered.
Clogging of the valve is eliminated by cleaning it after removal, and if it breaks down, you need to completely replace the check valve, but this will require a significant amount. With a prolonged downtime of the pumping station, a situation arises of the disappearance of water at the junction of the well and the pump. A special fill hole eliminates the problem.
If there is a seasonal drop in water level problem, the solution is to place the pump inlet circuit deeper into the well shaft. Deep immersion of the inlet circuit increases the likelihood of clogging; to prevent this, a filter is installed.
Insufficient voltage in the network is also the reason for the lack of water flow when the supply system is running. This is determined by the power supply tester. The wear of the pump blades is eliminated according to the following plan:
- disassembly of the pumping device using a special tool to facilitate removal;
- inspection of the impeller condition, if necessary - replacement of a broken blade;
- if it is impossible to replace a broken part (it all depends on the manufacturer), the pump completely changes.
When the pump is turned on frequently, the water supply is jerky. The reason is a breakdown in the operation of the automation unit (pressure gauge). The pressure gauge measures the pressure. The readings of this element can drop sharply, then the water will flow in jerks. This happens if the membrane of the pressure accumulator, which changes its size depending on the volume of water, has become unusable.
Breakage is determined by pressing the nipple, which makes access to the membrane. When air leaves it, it is serviceable. In case of water ingress, the membrane of the accumulator must be urgently replaced. To change the element, it is necessary to disassemble the battery case by unscrewing the bolts.
When it was found that the pump does not pump water, one of the reasons may be that the pressure in it is not correctly adjusted. The problem is eliminated according to the following scheme:
- the pumping station is turned off from the mains;
- water is drained from the water tank;
- the air pressure in the tank is measured through the nipple by an automobile pump with a pressure gauge or compressor, its optimal value is 90-95%;
- air is pumped into the water supply system.
- water is poured into the station;
- connects to the network with pressure control.
The air in the water supply system is pumped as follows. The cover with the pressure switch is removed by removing the plastic screw and changing the tightening force of the existing springs of the assembly. By turning one nut, the lower value of the pump is switched on. Clockwise rotation increases the pressure, while counterclockwise rotation causes the pressure to decrease.
Turning the other nut adjusts the pressure range between the lower and upper limits. The boundaries of the range are changed by rotating the element clockwise to expand, counterclockwise to decrease it.After the steps taken, the pumping station is connected to the power grid, and its performance is checked.
There are several more types of pumping station breakdown. For example, there is a constant injection of water, it happens when the regulation relay stops working due to wear. To eliminate the malfunction, it is necessary to clamp the stretched springs of the relay and, if necessary, clean it from clogging.
When the pump does not pump water from the well, the first step is to check if there is electricity in the circuit. If everything is in order, the cause of the malfunction may be the winding of the electric motor. In case of breakdowns in the winding, the motor does not work, and the smell of insulation burning is felt. The elimination of the problem consists in a complete replacement of the engine.