Do-it-yourself wall-mounted gas boiler repair

In detail: we will wipe the repair of a wall-mounted gas boiler with our own hands from a real master for the site my.housecope.com.

Posted by admin in DIY repair 06.05.2018 0 114 Views

  • Floor standing gas boiler series
  • Wall heating systems
  • Conclusion

Image - Do-it-yourself repair of a wall-mounted gas boiler

On the domestic market, there is a wide selection of household gas boilers from different manufacturers and in various price categories. Frankly cheap devices are not reliable, they have a minimum of functions and safety automation.

Models of leading brands have practically no drawbacks, but they are inaccessible due to their high cost. For these reasons, many experts recommend considering installations in the middle price category, domestic or foreign manufacturers. A striking representative of this category is the Slovenian Protherm gas boiler.

A wide range of natural gas heating systems for the home are produced under the Protherm trademark. The series of stationary heating systems is opened by the floor-standing boiler Protherm Wolf, which does not depend on electricity. "Wolves" are produced in two modifications - 12.5 and 16 kW of thermal power, the efficiency is 92.5%, the highest in the series. The heat exchanger made of steel is a two-way one, that is, the flue gases before leaving it flow through it twice in different directions. A single-stage atmospheric burner is ignited manually from a piezoelectric element.

The next floor gas boiler Protherm Bear in the series has several models:

KLZ - the only floor-standing double-circuit gas boiler Protherm with a two-pass cast iron heat exchanger, which has a built-in hot water boiler with a capacity of 90 liters. The unit is equipped with two expansion tanks - for the heating system and hot water supply. The power range from 18 to 49 kW includes 4 modifications. The burner is atmospheric, injection type, modulating. This means that the gas burner device can smoothly change the boiler output within a certain range. The installation is started by electric ignition.

Video (click to play).

TLO Is a completely non-volatile gas boiler Protherm. It differs from the previous model in the absence of an expansion tank and a circuit for DHW preparation. The atmospheric burner operates in a single-stage mode, ignited using a piezoelectric element. The range of modifications - 4 units with a capacity from 18 to 45 kW. The device does not require an electrical connection, but its level of automation is also limited, only safety devices are installed.

PLO - a model with a cast-iron two-way heat exchanger and an atmospheric burner with a two-stage operation. A forced smoke exhaust system can be installed as an option. Ignition is carried out from a piezoelectric element, a line of 5 modifications covers the power range of 18-49 kW. Household single-circuit floor-standing boiler Protherm Bear PLO is a somewhat simplified and cheaper version of the KLZ model.

Model KLOM includes 4 modifications operating in the power range from 18 to 49 kW. There is no DHW circuit or there is no built-in boiler, the cast-iron heat exchanger is heated by an injection-type modulation burner. The gas boiler is fired up and started automatically from an electrical element.

Floor standing gas boiler Protherm Bear

The series is completed by floor heating units Protherm Bizon and Protherm Grizzly, whose power reaches 80 and 150 kW, respectively.In addition, Protherm Bison units are equipped with a Lamborghini external gas burner device with forced air supply, operating in a two-stage mode.

In this series, the following models of Protherm gas boilers are produced:

  1. Panther KTV, KOV;
  2. Panther KTO, KOO;
  3. Cheetah MOV, MTV;
  4. Tiger.

Wall-mounted double-circuit gas boiler Protherm Panthera KTV and KOV are equipped with a stainless steel heat exchanger and a flow element for DHW preparation. The line includes 2 modifications with a power of 25 and 30 kW, the units are equipped with their own circulation pumps and three-way valves. The Panther is a turbocharged double-circuit gas boiler of the Protherm trademark, in which the burners operate in a closed combustion chamber with forced air supply by a fan. Installations Panther KTO and KOO are available only with a capacity of 25 kW and differ from the previous version by the absence of a circuit for supplying hot water. The boilers operate automatically, starting from the stage of ignition from an electrical element.

Less powerful gas boilers Protherm Cheetah (11 and 23 kW) are also equipped with a DHW circuit, the MOV modification works at atmospheric pressure, MTV - with a fan with a closed combustion chamber. The unit's automation has the function of preheating a flow-through heat exchanger for hot water supply, which makes hot water supply almost immediately after opening the tap. The electronic unit that controls the operation of the Cheetah makes it possible to connect to it an automation that responds to changes in the temperature of the outside or room air. To do this, it is enough to purchase a remote thermostat for the Protherm gas boiler, it is sold as an additional equipment.

Heating units Protherm Tiger differ from other wall-mounted models with a built-in hot water boiler with a capacity of 45 liters. The water in it is in a heated state, and in addition to other automatics, a timer is used in "Tigers", it makes it possible for consumers to receive hot water at a specified time.

The company produces boiler plants operating on other types of energy carriers, as well as other additional equipment, such as a heat generator for a Protherm gas boiler. It is an indirect heating boiler that can be used to supply large quantities of hot water. All gas heaters are equipped with reliable safety automation, one of the tasks of which is to turn off the gas supply when the burner flame goes out. Error F29 appears on the display, for Protherm gas boilers this means that the burner has gone out and gas access is blocked.

Slovenian gas installations in the mid-price range are very popular with homeowners. They are automated, easy to use, and require a minimum of attention. Maintenance must be performed once a year, which includes cleaning the heat exchanger and the flue gas duct from soot. For stable operation of the apparatus, the gas valve of the Protherm boiler is periodically adjusted in it.

If the heating system is based on a gas boiler, this allows you to feel the full taste of the convenience of an autonomous heating system: the possibility of self-regulating the temperature regime of the house. But, of course, sometimes such complex units require restoration or modernization. Otherwise, you can create a condition that is dangerous to health and life. A gas boiler repair technician is a person who will avoid such situations.

Read also:  How to start repairing an apartment with your own hands in stages

Image - Do-it-yourself repair of a wall-mounted gas boiler

Any part of the boiler can fail for any reason: poor-quality assemblies, improper operation, hit the expansion tank with an object (and now there are puddles under it every day). Be that as it may, the repair of gas boilers or any others must be carried out very carefully, especially when it comes to the safety group responsible for the correct operation.

At the moment, any foreman responsible for the repair of gas boilers baxi or other knows that the security group consists of the following elements:

Attention! If any sensor fails, you can breathe in carbon monoxide, which the system "did not notice", and get an explosion if the electrode does not work properly.

  • a thrust sensor with a plate rated at 75 degrees Celsius. This device monitors the state of the boiler chimney, reacts to a failure in the removal of combustion products into the chimney, their exit to the smoke extractors. As a result, it heats up, works, but it is best if a gas alarm is purchased in addition to it;
  • monostat to protect turbo boilers from insufficient smoke removal due to a clogged heat exchanger or chimney;
  • limit thermostat that controls the water in the boiler. If it boils, the overheating sensor turns off the boiler;
  • an ionization electrode to control the presence of a flame. Quite often, the repair of viessmann gas boilers begins precisely with checking the electrode, since the operation of a gas boiler without a flame can even provoke an explosion.
  • blasting valve for pressure control. At pressures above 3 bar, the system will force the boiler to discharge hazardous surpluses.

Image - Do-it-yourself repair of a wall-mounted gas boiler

Some types of repairs to gas boilers can only be performed by specialists. By the way, in order to prevent boiler breakdown, one must not forget about the UPS for the gas boiler. No matter how skilled the owner is, where such a unit is located, the variety and complexity of the automatic control and management system of the boiler does not always allow a person to correct the operation of the boiler without experience. Repairing a Danko or Viesmann gas boiler at the level of fixing the work of the board also sometimes requires special equipment, which the owners simply cannot have.

The operation and repair of gas boilers from different manufacturers will differ, but, as a rule, electronic boards have a lot in common in their principle. Repairing control boards for gas boilers is quite difficult for a novice craftsman, therefore experienced specialists can tell some of their secrets of setting up boards.

Firstly, you should never immediately apply full voltage to it, otherwise the repair of vaillant or "Zhukovsky" gas boilers may end there: you will need to completely replace the burned-out automation for the boiler.

It is better to connect all sensors with "correct" data that are used in the operation of the boiler. And in order to avoid surges, use a voltage stabilizer for a gas boiler. In the instructions for a specific boiler, all readings will be indicated: as the next sensor is connected, it will be possible to see where the system "sags".

For example, if you need to check how the voltage is supplied to the gas valve, first a board test is carried out, taking into account the operation of the controllers. Then you should check the sensors of the safety groups for a break in the contact. After that, the board is given a job task: to light up the boiler. The pump is switched on sequentially, then it is controlled how the liquid or antifreeze circulates. When the turbine is turned on, it will be possible to see if there is a false flame. Only then can voltage be applied to the board. If the unit is malfunctioning, then the repair of vaillant or baxi gas boilers may not end there.

Training in the repair of gas boilers in the field of setting up automation (in particular, control boards) lasts more than one week. This is due to the fact that the faulty operation of the boiler can cost its owner the life: therefore, the work of a specialist is akin to the work of a doctor who is responsible for the existence of his patient.