DIY repair wipe the skat

In detail: do-it-yourself repair wipe the slope from a real master for the site my.housecope.com.

After installation, the Protherm electric boiler worked for three days and stopped with an error F 20. I looked at the instructions - something with a thermostat. What to do is not said. Can you help with advice?

Service technician response:

The automatic overheat protection of the device has been triggered. It is possible to remove the equipment from the emergency function by yourself, although for electric boilers of these models, the unlocking actions are the work of the service department. Try to find the hidden emergency button on the thermostat and press it. If
it will not help - you will need boiler diagnostics.

The Protherm Skat 18 K electric boiler is set to the maximum night mode, but overnight the pressure drops from 1.8 bar to 0.6 - the boiler cannot turn on in the morning and writes error F22. Please help me figure it out.

The answer of the repairman of boiler units:

Low pressure in the heating circuit may be due to leaks in the heating system and a malfunction of the expansion tank in the unit. It is necessary to look at the tightness of the device components. There may be problems with the tank, or a coolant leak through the system.

The electric boiler Proterm Skat for 12 kW is often turned off, but does not write an error. The boiler is 3-phase, the voltage was measured: on two phases 6 each, and on the third - zero. Can this affect?

Service employee response:

In this case, there is clearly an electrical problem. If there are two phases, and the third is not, then this phenomenon should be eliminated as soon as possible, since the board may burn out. Possible reasons: a wire has come off in the bag, there are bad terminals in the machine, or the problem is in the starter.

Video (click to play).

Electric boiler Skat 6kW. Worked not a full season. There is a coolant in the system. Circuit breaker recently knocked out. When the machine is turned on, the boiler works for a while, then the machine knocks out again.

Service technician response:

Perhaps the heating elements are out of order. Diagnostics of the device is required.

Please tell me what could be the problem in the Skat 6 kw electric boiler: the boiler was launched 3 years ago to heat the bath and it worked perfectly (1-2 kw was enough), and this year the heating power dropped several times while the supply voltage was Normally and tena, when turned on, alternately heat the water to a certain temperature in the same way, i.e. they are all working, but in order to achieve the same temperature as in previous years, it is necessary to turn on the boiler at full power 6kw. The thermal performance of the bath has not changed.

The answer of the repairman of boiler units:

Probably, the block of heating elements is out of order. It is also necessary to check the dirt filter.

When installing and starting up the Skat 9 kv boiler, it gives an error f20. what to do in this case?

Service employee response:

Temperature cutout tripped.

Installed electric boiler Proterm 14 kW. One of the fuses located on the switching power supply burned out, I can't figure out what the rating is, tell me, please!

Service technician response:

when a new boiler Proterm Skat-6 is started, and water is pumped into the system, an error F20 is issued (activation of the emergency thermostat), the water does not heat up and the pump does not turn on. Cook rectify the problem on his own, as there is no service center within a radius of 100 km.

The answer of the repairman of boiler units:

We recommend checking: air in the boiler heat exchanger; no duct through the apparatus; fuse on the control board.

Protherm skat 18 kW the signal lamp (exclamation mark) is on AND HDO, the green diode is on, the circulation pump is working, but the heating elements do not turn on.I tried to reset the error by pressing the button that is inside, on top. seems to work, but after 20 minutes the heating elements do not turn on again pressure 1.5 MPa temperature 35 degrees

Service employee response:

Your electric boiler is overheating. The reason is that the sump on the return line to the boiler is clogged with dirt (if one was installed during installation) or the contacts in the relay on the control board are sticking.

Electric boiler Protherm SKAT 6 - 24 K. It worked normally for several years. Now the following picture takes place: after turning on, neither the battery nor the pipes emanating from the boiler practically heat up. After a few minutes of operation, the temperature on the thermometer becomes> 90 degrees, and the boiler turns off. The pump (judging by the sound and vibration) is running.

Service technician response:

Most likely a problem with the circulation pump. But it is possible to determine for sure only when diagnosing the boiler.

Tell me please! We bought an electric boiler Proterm skat 28, installed everything as per the instructions, pressure 1.5 bar, turned it on at 380 volts. The boiler does not give any signs of life at all, the display does not shine, what could it be?

The answer of the repairman of boiler units:

The display does not light up: the fuses on the control board are blown, there is no communication between the control board and the display board (check the loop).

I have a Skat 12K apparatus. He worked for 6 years. At the moment, water is constantly dripping from the overflow tap coming from the emergency valve. The working pressure is from 0.9 to 2.5. It drips until the boiler stops completely after about 5-6 hours.

Did your familiar operators advise you to change the emergency valve and expansion tank inside the boiler? What is your advice on how to be? I also could not tighten the union nut of the flexible line.

Service employee response:

It is recommended to check the operating pressure in the expansion vessel of the electric boiler. If it is not possible to establish the required pressure in the tank, the expansion tank will need to be replaced.

Breakdown of heating equipment is always unpleasant, and breakdown of a heating boiler is doubly unpleasant. Even if you are the owner of such PROTHERM equipment, this is not a guarantee that the boiler will not break down.

Read also:  DIY car door trim repair

Electric boiler breakdowns: the most common causes