Do-it-yourself split system repair vibration

In detail: do-it-yourself split system repair vibration from a real master for the site my.housecope.com.

Have you already installed the air conditioner, but when you turn on the air conditioner, vibration appears or is there vibration of the air conditioner during operation? Do not worry! This is fixable! We will help you, because we know how to reduce, reduce the vibration of the outdoor unit of the air conditioner.

Then contact us! Reducing, eliminating vibration, hum, noise from the air conditioner is possible! Service price:

  1. Reducing vibration of the air conditioner ECONOMY 1. Work to reduce vibration inside the outdoor unit. The price is 2000 rubles.
  2. Reducing vibration of the air conditioner ECONOMY 2. Installing rubber gaskets between the wall and brackets. The price is 3000 rubles.
  3. Reducing vibration of the OPTIMUM air conditioner. Installation of special vibration dampers (made in Italy) between the brackets and legs of the external air conditioner unit. With partial dismantling and subsequent installation of the external unit of the air conditioner. The price is 5000 rubles.
  4. Reducing vibration of the LUX air conditioner. Complex elimination of air conditioner vibration. The price is 10,000 rubles. Includes all three types of work:
    • Work to reduce vibration inside the outdoor unit.
    • Installing rubber gaskets between the wall and brackets.
    • Installation of special vibration dampers between the brackets and legs of the outdoor unit of the air conditioner.

All prices include departure, the work of the best specialists and consumables.

All work is carried out with access to the external unit - for example, when it hangs under the window. If access to the external unit is closed by a deaf glass unit, then the glass unit is removed for the period of repair work, and then put back in place. These works cost another 1,000 to 2,000 rubles, depending on the size and weight of the glass unit. If the external block is out of the window, then additional services of an industrial climber are possible - another 12,000 rubles. This requires a key from the roof.

Video (click to play).

We can also bring to your attention the reduction of the vibration of the washing machine - the installation of special vibration dampers under the feet of the washing machine. The price of the service is 2000 rubles.

Strong vibration of the outdoor unit of the air conditioner interferes with working and resting. We can reinstall the air conditioner by substituting special shock absorbers (made in Italy) under the legs of the external air conditioner unit, special gaskets between the wall and brackets of the external air conditioner unit, and even inside it. This set of measures will help get rid of vibration in the outdoor unit of the air conditioner. The work performed by us gives a noticeable decrease in vibration, hum, noise from the air conditioner, after which you can safely be in the room. Our clients were satisfied for many years of our work!

Below is a technology developed by us to reduce the vibration of the outdoor unit of the air conditioner, which has been tested experimentally on various models of air conditioners.

Vibration mounts under the legs of the outdoor unit reduce vibration transmission from the outdoor unit of the air conditioner. The vibration mount consists of two independent bolts, industrially molded into rubber. At the same time, as experience shows, this rubber can withstand both tropical heat and Russian winter. It looks like this. Click on the photo to enlarge.

There can be many reasons for increased vibration.
First, you need to open the cover of the outdoor unit and see if the tubes of the case are touching and whether the fan bracket is properly fixed.
the tubes are bent, the bracket can be fixed better.
Further, if the vibration remains (it is felt most of all on the ports - this is already an increased vibration of the compressor), then you need to deal with its transfer through the brackets to the wall in three ways at once:

one.Moving the unit to a harder wall
2. Replacing brackets with more rigid ones with a hole not in the center for an anchor or a screw, but as low as possible (then the bracket will not “walk” along the wall together with the block to create a hum)
3. Installation of vibration dampers with bolt insulation from the bracket through rubber.
Ideal vibration mounts from Copeland, but they are not a panacea.

Reducing vibration, hum, noise from the air conditioner is possible!

Many people, having installed a split system cheaply, at the lowest price, for those who save on everything and do not work in the best way, often face the fact that their air conditioner hums, makes noise, emits a strong vibration, hum. The walls are humming. Low frequency noise from the compressor of the outdoor air conditioner unit interferes with sleep. Neighbors often complain.

The reasons for the malfunction of your equipment are a constructive error of the manufacturer or a factory defect. Sometimes the cause of the rattling is inside the external unit of the split system. In other cases, it is caused by the fan or compressor of the outdoor unit.

Below is a technology developed by us for reducing the malfunction from the external unit of the device, which tested experimentally on various models of air conditioners. Our clients have been satisfied for many years of our work.

In order to reduce vibration, hum and noise from the device, we put special shock absorbers under the legs of the external unit, and also, in some cases, if necessary, between the brackets and the wall and even sometimes inside the external unit. Our specially selected gaskets effectively reduce shaking from the outdoor unit. This has been proven experimentally - customers stop complaining about vibration from the split system. That is why our split system installation is of such high quality and we are recommended.

Our service provides a quite noticeable tangible reduction in vibration of the outdoor unit by 80-90%, after which you can safely be in the room.

If you have already installed the equipment, and you are annoyed by the shaking from the external unit of the split system, then we can reinstall it by substituting our special shock absorbers under the legs of the external unit

The vibration generated by the air conditioner sometimes creates such a strong noise effect that further operation of the split system becomes impossible. The specialists of the service center or installers who installed the equipment will be able to understand the reason and eliminate it.

Both units of the split system can be vibrated. The causes are very different. If the indoor unit vibrates, dirty filters or a fan (squirrel wheel) may be the culprit. The uneven accumulation of dirt creates an imbalance that causes vibration. Cleaning the indoor unit will usually fix the problem.

Also, imbalance can be caused by a defect in the squirrel wheel: curvature of the blades, curvature of the axis, asymmetry and other similar disadvantages. In this case, vibration will be noticeable from the first day of operation of the air conditioner, when it is under warranty. It requires a warranty repair of the indoor unit with the replacement of the damaged part.

In addition, the indoor unit of the air conditioner vibrates with such a defect in the squirrel-cage wheel, such as the breaking of lamellas. Breakdown can occur from careless handling during installation or during operation, if the installer or the owner of the air conditioner himself has made a negligence. In this case, the replacement of the fan of the indoor unit is carried out at the expense of the installers or the owner of the split system himself. To prevent this from happening, it is recommended to carry out installation and further service only in specialized service centers, where the masters are highly qualified and experienced.

Read also:  Ardo t80x DIY repair

Incorrectly laid freon line (without thermal insulation)

If the outdoor unit of the air conditioner vibrates, the reasons may be as follows:

  • The installation was carried out on brackets made from a corner of small thickness.
  • The outdoor unit is installed on a weak surface (such as a balcony railing).
  • When attaching the brackets to the wall of the panel house, the reinforcement was touched.
  • There are no special vibration damping pads between the legs of the outdoor unit and the surface of the brackets.
  • Too short and straight freon line connecting the air conditioning units. The length of the freon line recommended by manufacturers is 3-5 meters. Even if the units of the split system are nearby, these requirements must be observed. In addition, the line must contain a vibration damping bend and not run in a straight line.
  • Interblock communications are laid without thermal insulation.
  • Factory defect in fastening parts inside the outdoor unit housing. A part fixed with an offset (for example, a freon filter, etc.) touches the housing cover and resonates.

Unprofessional installation of the air conditioner

If the external unit of the air conditioner vibrates, the emitted sound disturbs not only the owners, but also the neighbors. To eliminate vibrations, it is necessary to observe the operation of the air conditioner in order to accurately identify the cause. The list and cost of work will depend on the results:

If it is established that the cause is a factory defect, the service center specialists will make a warranty repair with the replacement of the defective part. In this case, the air conditioner must be under warranty with the factory seals preserved.

If the installation was carried out with violations of the technology, and as a result the outdoor unit of the split system vibrates, the outdoor unit will need to be reinstalled. During the reinstallation process, it will be necessary to take into account all the mistakes made and correct them. This can be choosing a different location for the outdoor unit, connecting a new freon line of the recommended length and configuration, replacing brackets and other work.

It is also recommended to install vibration damping pads between the surface of the brackets and the legs of the outdoor unit.

When choosing a company to install a split system, pay attention to the experience and professionalism of the craftsmen, the availability of specialized equipment and the provided warranty. Otherwise, there is a high probability of encountering vibrations of the outdoor or indoor unit from the air conditioner and the resulting additional costs.

Image - Do-it-yourself split system repair vibration

There are situations when the outdoor unit of the air conditioner starts to make noise and vibrate, thereby causing discomfort to you and your neighbors. More budget air conditioners often make noise and vibrate, although no one is safe from compressor vibrations in branded models. This is especially true if the outdoor unit is installed on a balcony slab. With this method of installation, a decent hum is created on the balcony, which is transmitted to the room. Similar problems are inherent in air conditioners that have worked for more than three to five seasons, the shock absorption cushions of the compressor have become unusable. Moreover, it pesters at night, when a person wants to sleep peacefully in the coolness and silence after a hard day's work.

One of our clients suffered from this problem, and he had a rather expensive inverter air conditioner. He gave us the idea of ​​combating noise, which we successfully implemented, satisfying all the whims of the client.

The solution is quite simple - the lining of rubber cushions-silent blocks under the “paws” of the outdoor unit. The pillows are made of soft, but tear-resistant rubber, into which metal threaded pins, not connected to each other (!) - the premises.

Those gum spacers that come with Lq and Samsung air conditioners do not give a positive effect, because when using them, the block is rigidly coupled to the bracket. After a couple of years, the rubber dries up in the sun, the fastening nut loosens, as a result, the noise of the air conditioner is even greater than when installing without using spacers.

We do not sell such pillows. You can buy them at the car market. It is called like this: Radiator pillow (upper) 86-00 FORD 1519545 Ford Transit 1992-2000

Video of installed vibration dampers:

Store administrator. Consultant. Installation specialist.

Dear specialists!
Tell me if there is a solution to my problem.
Installed splits Mitsubishi SRK40HJ. The external blocks emit a slight acoustic noise, but vibrations are transmitted to the walls so that the guard. We are not talking about turning them on at night.
House of 9 floors, outer panels are two-layer with foam filling.
Maybe it's the way of fastening? I sin on the fact that the brackets are somehow indistinct from the bent corner 2 mm thick.
Are there any solutions?
Thank you.

You can try to replace it with a corner that is harder and more reliable to the wall. Are there rubber bagels between the corner and the kondeem?

NNN wrote:
that the brackets are somehow indistinct from the bent corner 2 mm thick.

2mm isn't too bad. Is the bracket welded from two corners?

Installers have not been contacted with this issue under warranty?

2BV We are not talking about a guarantee. Splits are used for ear, but I know for certain that they have not been used almost. And the guys put their own. They immediately warned that this is too powerful a device and may be buzzing. Now, behold, I'm scratching my turnips.

BV wrote:
Is the bracket welded from two corners?

Yes. But I've seen others, much more massive.

NNN wrote:
Mitsubishi SRK40HJ

MH are noisy. Affected by the build quality of the cases. Nearby we have a cafe with two “two-propeller” MPs on the facade. Both roar and rumble (already ringing) - I sympathize with those who live in the neighborhood. IUs are different, but they are more expensive.

BV wrote:
Are there rubber bagels between the corner and the kondeem?

IMHO this won't help. Resonates the body. If you just try to sort it out, glue the joints with damper tape. It is worth checking the balance of the fan impeller.

NNN wrote:
Yes. But I've seen others, much more massive.

Usually they have a common rail. Try it. However, I doubt it will help.

Kvost wrote:
Try it. However, I doubt it will help.

I will try, but it comes to mind to make a "gallows" -type bracket.: Yu

unfortunately it is not possible to fix the problem. So, how the device itself vibrates - the compressor. Unfortunately, there is a sad experience. It is customary in our Kuban to build brick, private houses with an air gap between two rows of bricks. So, at a friend's 9, the Samsung made a hum in the house like a tractor, suffered for 2 years, and rubber bands and gaskets were all in vain. Everything was solved simply - I installed an inverter split. And as the grandmother whispered. silence.
and this problem is not only for him.

Read also:  DIY rusty fender repair

alkor2000 wrote:
So, how the device itself vibrates - the compressor.

Shitty apparently. Next to this cafe-owners of MN there is a store where a similar LG device is installed (naturally, a non-inverter). For some reason, you can hardly hear it at all.

There was such a problem. (The inverter did not pass at a price.) Mechanical decoupling of block arms through springs. If possible, I will throw off the photo. The result is positive.

So far I decided to do the following set of activities:

  1. disassemble the case of the outdoor unit and glue it with vibroplast
  2. replace brackets with more massive ones
  3. weight the compressor with lead extracted from the car accumulator (on the advice of the great Pb).
    I plan to do this next Saturday the 25th, I will report on the result.
    If it does not help, I will install inverters.

Fresh wrote:
Mechanical decoupling of block brackets through springs.

This is the first thing that came to mind, even came up with which springs are from Zhiguli valves, but then the copper tubes will be subject to vibration.

There is a special corrugation of various diameters for refrigeration systems. At first, they made solinoids (2-3) turns. It is not necessary to make the structure heavier.

NNN wrote:
disassemble the case of the outdoor unit and

  • run disassembled.After that, decide what action to take and whether it's worth it at all.

NNN wrote:
weight the compressor with lead extracted from the car accumulator (on the advice of the great Pb).

Image - Do-it-yourself split system repair vibration

It is very cool to put a block on 4 engine mountings from a Zhiguli. And silenceaa.

And the body of the block has nothing to do with low-frequency vibrations transmitted to the walls. It is useless to glue it.

The legacy of the ruined worsted production .. You will fly by - we will select the set .. Just don’t tell anyone (!). The only sensible thing I’ll say is: under a load of 80 kg it is compressed by 1 cm.

Radio wrote:
It is very cool to put a block on 4 engine mountings from a Zhiguli. And silenceaa.

I have silence without pillows.

Radio wrote:
And the body of the block has nothing to do with low-frequency vibrations transmitted to the walls. It is useless to glue it.

How to say. Some manufacturers glue body joints at the factory. Image - Do-it-yourself split system repair vibration

Kvost wrote:
Some manufacturers glue body joints at the factory.

Perhaps, but it has nothing to do with the trembling walls.
A bad case can give off a nasty bounce, which will help gluing, but vibrates the unit is not due to the housing. Image - Do-it-yourself split system repair vibration